CoChat

Reproducibility of Masked Hypertension in Adults With Untreated Borderline Office Blood Pressure: Comparison of Ambulatory and Home Monitoring

Viera, Anthony J., Hinderliter, Alan L., Kshirsagar, Abhijit V., Fine, Jason, Dominik, Rosalie · 2010 · American Journal of Hypertension
Cited by 75

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

BACKGROUND: We examined short-term reproducibility of masked hypertension (MH) among adults with recent "borderline" office blood pressure (BP) and compared agreement of ambulatory BP monitoring (ABPM) and home BP monitoring (HBPM) in detecting MH. METHODS: Fifty participants underwent repeated office BP measurements, 24-h ABPM, and HBPM sessions 1-week apart. Participants with office average <140/90 mm Hg were considered to have MH if daytime ABPM average was ≥135/85 mm Hg; they were considered to have MH by HBPM if the average was ≥135/85 mm Hg. Agreements were quantified using κ. We calculated sensitivity and specificity of daytime ABPM-office average pairing and HBPM session-office average pairing for diagnosing MH using a "standard" of two pairings of office and 24-h average ABPM (using a cutoff ≥130/80 mm Hg). RESULTS: Prevalence rates of MH based on office-daytime ABPM pairings were 54 and 53%, with agreement of 73% (κ = 0.47; 95% confidence interval (CI) 0.21-0.72). MH was less prevalent (43 and 35%) using HBPM-office pairings, with agreement of 69% (κ = 0.34; 95% CI 0.06-0.62). Office-HBPM pairings and office-daytime ABPM pairings had poor agreement on MH classification on both occasions, with κ of -0.06 and 0.10. Sensitivity and specificity of daytime ABPM-office pairing were 93 and 83%. Sensitivity and specificity of HBPM-office pairing were 23 and 67%. CONCLUSIONS: MH appears to have fair-to-moderate reproducibility, favoring the hypothesis that office BP measurement systematically fails to identify some patients who should be treated as hypertensive. HBPM may not be adequate for detecting MH, or may identify a different "type" of MH than ABPM.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1038/ajh.2010.158

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 75

Metadata

Authors
Viera, A. J., Hinderliter, A. L., Kshirsagar, A. V., Fine, J., & Dominik, R.
Venue
American Journal of Hypertension
Published
2010-07-29
Volume
23
Issue
11
Pages
1190-1197
ISSN
  • 0895-7061 (ISSN-L)
  • 1941-7225
OpenAlex
W2025225205
Cited by
75
References
3
FWCI
2.45
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Reproducibility of Masked Hypertension in Adults With Untreated Borderline Office Blood Pressure: Comparison of Ambulatory and Home Monitoring. https://app.cochat.ai/papers/10.1038/ajh.2010.158
The paper
Viera, A. J., Hinderliter, A. L., Kshirsagar, A. V., Fine, J., & Dominik, R. (2010). Reproducibility of Masked Hypertension in Adults With Untreated Borderline Office Blood Pressure: Comparison of Ambulatory and Home Monitoring. American Journal of Hypertension. https://doi.org/10.1038/ajh.2010.158

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.