Stroke Risk in Treated Hypertension Based on Home Blood Pressure: the Ohasama Study
The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Several observational studies have shown that treated hypertensives are characterized as having worse prognosis than nonhypertensives. However, there is little evidence based on home blood pressure (home BP) measurement. We compare the risk of stroke between untreated individuals and those taking antihypertensive medication based on home BP and casual-screening BP (casual BP) in the general population. METHODS: The study included 1,690 untreated and 700 treated subjects aged >or=35 years. We measured home BP and casual BP at the beginning of the study. The risk of first stroke was examined by using the Cox proportional hazards model. RESULTS: During 11.9 years of follow-up, we observed 242 first-time stroke cases. Treated subjects had significantly higher risk for stroke than untreated subjects based on home BP (relative hazard (RH) = 1.48) as well as on casual BP (RH = 1.78), adjusted for systolic BP values and characteristics. When subjects were classified into six categories based on BP (optimal, normal, high normal, and grade 1-3 hypertension), RHs in treated hypertensives linearly increased (trend P < 0.01) based on home BP. However, there was no consistent association for casual BP (trend P: not significant) in treated subjects. Stroke risk was linearly increased regardless of the BP information source in untreated subjects (home BP: trend P < 0.01, casual BP: trend P < 0.01). CONCLUSION: The results suggest a strong association between elevated home BP and increased risk of stroke. Home BP is a better tool to assess stroke risk, especially in treated hypertensives.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Prognostic accuracy of day versus night ambulatory blood pressure: a cohort study
Boggia, J., Li, Y., Thijs, L., Hansen, T. W., Kikuya, M., Björklund-Bodegård, K., Richart, T., Ohkubo, T., Kuznetsova, T., Torp-Pedersen, C., et al. (2007) · The Lancet · doi:10.1016/s0140-6736(07)61538-4 · Cited by 887
Self-citationBobrie, G. (2004) · JAMA · doi:10.1001/jama.291.11.1342 · Cited by 842
Ohkubo, T., Asayama, K., Kikuya, M., Metoki, H., Hoshi, H., Hashimoto, J., Totsune, K., Satoh, H., & Imai, Y. (2004) · Journal of Hypertension · doi:10.1097/00004872-200406000-00009 · Cited by 287
Self-citationObara, T., Ohkubo, T., Funahashi, J., Kikuya, M., Asayama, K., Metoki, H., Oikawa, T., Hashimoto, J., Totsune, K., & Imai, Y. (2005) · Journal of Hypertension · doi:10.1097/01.hjh.0000178334.33352.56 · Cited by 112
Self-citation
Cited by
The Japanese Society of Hypertension Guidelines for the Management of Hypertension (JSH 2019)
Umemura, S., Arima, H., Arima, S., Asayama, K., Dohi, Y., Hirooka, Y., Horio, T., Hoshide, S., Ikeda, S., Ishimitsu, T., et al. (2019) · Hypertension Research · doi:10.1038/s41440-019-0284-9 · Cited by 1,880
Self-citationDiretrizes Brasileiras de Hipertensão Arterial – 2020
Barroso, W. K. S., Rodrigues, C. I. S., Bortolotto, L. A., Mota-Gomes, M. A., Brandão, A. A., Feitosa, A. D. D. M., Machado, C. A., Poli-de-Figueiredo, C. E., Amodeo, C., Mion, D., et al. (2021) · Arquivos Brasileiros de Cardiologia · doi:10.36660/abc.20201238 · Cited by 1,068
Stergiou, G. S., Asayama, K., Thijs, L., Kollias, A., Niiranen, T. J., Hozawa, A., Boggia, J., Johansson, J. K., Ohkubo, T., Tsuji, I., et al. (2014) · Hypertension · doi:10.1161/hypertensionaha.113.02741 · Cited by 304
“Moreover, treated subjects are more familiar with the office setting, which might have reduced their office BP.”
ResultInfluentialSelf-citationas members of the Japanese Society of Hypertension Committee for Guidelines for Self-monitoring of Blood Pressure at Home, Imai, Y., Kario, K., Shimada, K., Kawano, Y., Hasebe, N., Matsuura, H., Tsuchihashi, T., Ohkubo, T., Kuwajima, I., et al. (2012) · Hypertension Research · doi:10.1038/hr.2012.56 · Cited by 203
Self-citationon behalf of Hypertension Objective Treatment Based on Measurement by Electrical Devices of Blood Pressure (HOMED-BP) investigators, Asayama, K., Ohkubo, T., Metoki, H., Obara, T., Inoue, R., Kikuya, M., Thijs, L., Staessen, J. A., & Imai, Y. (2012) · Hypertension Research · doi:10.1038/hr.2012.125 · Cited by 186
Self-citation
Metadata
- Authors
- Yasui, D., Asayama, K., Ohkubo, T., Kikuya, M., Kanno, A., Hara, A., Hirose, T., Obara, T., Metoki, H., Inoue, R., Totsune, K., Hoshi, H., Satoh, H., & Imai, Y.
- Venue
- American Journal of Hypertension
- Publisher
- Oxford University Press (OUP)
- Published
- 2010-05-01
- Volume
- 23
- Issue
- 5
- Pages
- 508-514
- ISSN
- 0895-7061 (ISSN-L)
- 1941-7225
- OpenAlex
- W2037291169
- Cited by
- 48
- References
- 5
- FWCI
- 2.25
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.