Electronic Monitoring of Adherence, Treatment of Hypertension, and Blood Pressure Control
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Although it is generally acknowledged that electronic monitoring of adherence to treatment improves blood pressure (BP) control by increasing patients' awareness to their treatment, little information is available on the long-term effect of this intervention. METHODS: In this observational study among a total of 470 patients with mild-to-moderate hypertension, adherence was measured in 228 patients by means of both the Medication Event Monitoring System (MEMS) and pill count (intervention group), and in 242 patients by means of pill count alone (control group). During a follow-up period of 1 year consisting of seven visits to the physician's office, BP measurements were performed and medication adjusted based on the achieved BP. In addition, at each visit adherence to treatment was assessed. RESULTS: On the basis of pill counts, median adherence to treatment did not differ between the intervention group and the control group (96.1% vs. 94.2%; P = 0.97). In both groups, systolic and diastolic BP decreased similarly: 23/13 vs. 22/12 mm Hg in the intervention and control group respectively. Drug changes and the number of drugs used were associated with BP at the start of study, but not with electronic monitoring. CONCLUSIONS: In this study, electronic monitoring of adherence to treatment by means of MEMS did not lead to better long-term BP control nor did it result in less drug changes and drug use.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Verberk, W. J., Kroon, A. A., Kessels, A. G. H., Dirksen, C., Nelemans, P. J., Lenders, J. W. M., Thien, T. A. B. M., van Montfrans, G. A., Smit, A. J., & de Leeuw, P. W. (2003) · Blood Pressure · doi:10.1080/08037050310022405 · Cited by 32
Self-citation
Cited by
Tomaszewski, M., White, C., Patel, P., Masca, N., Damani, R., Hepworth, J., Samani, N. J., Gupta, P., Madira, W., Stanley, A., et al. (2014) · Heart · doi:10.1136/heartjnl-2013-305063 · Cited by 404
Drug adherence in hypertension: from methodological issues to cardiovascular outcomes
Hamdidouche, I., Jullien, V., Boutouyrie, P., Billaud, E., Azizi, M., & Laurent, S. (2017) · Journal of Hypertension · doi:10.1097/hjh.0000000000001299 · Cited by 111
How to Screen for Non-Adherence to Antihypertensive Therapy
Gupta, P., Patel, P., Horne, R., Buchanan, H., Williams, B., & Tomaszewski, M. (2016) · Current Hypertension Reports · doi:10.1007/s11906-016-0697-7 · Cited by 84
Chan, A. H. Y., Foot, H., Pearce, C. J., Horne, R., Foster, J. M., & Harrison, J. (2022) · PLOS ONE · doi:10.1371/journal.pone.0265715 · Cited by 47
Metadata
- Authors
- Onzenoort, H. A. W. V., Verberk, W. J., Kroon, A. A., Kessels, A. G. H., Neef, C., van der Kuy, P.-H. M., & Leeuw, P. W. D.
- Venue
- American Journal of Hypertension
- Publisher
- Oxford University Press (OUP)
- Published
- 2012-01-01
- Volume
- 25
- Issue
- 1
- Pages
- 54-59
- ISSN
- 0895-7061 (ISSN-L)
- 1941-7225
- OpenAlex
- W1968887684
- Cited by
- 32
- References
- 1
- FWCI
- 2.96
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.