CoChat

Comparison of Illumina paired-end and single-direction sequencing for microbial 16S rRNA gene amplicon surveys

Open access
Werner, Jeffrey J, Zhou, Dennis, Caporaso, J Gregory, Knight, Rob, Angenent, Largus T · 2012 · The ISME Journal
Cited by 123

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

High-throughput sequencing of 16S rRNA gene amplicons is a valuable tool for comparing microbial community structure among hundreds of samples for which researchers have primarily used the 454 Pyrosequencing platform. The Illumina platform produces far more reads than 454 (up to 1.5 billion reads per run, compared with 1 million reads per run on a 454 plate of comparable cost), but produces fewer base pairs (bp) per read (75–150 bp per read compared with 250–400 bp per read on 454). The shorter Illumina reads may reduce phylogenetic resolution, both in terms of picking operational taxonomic units (OTUs) and determining evolutionary distances between OTUs. The paired-end (PE) approach where each molecule is sequenced from both the 5′ and 3′ ends can double the number of bp per read for the Illumina platform. Some researchers have obtained overlapping PE Illumina reads covering the V3 (Bartram et al., 2011) or V6 (Zhou et al., 2011) regions of 16S rRNA genes, but many other useful primer regions (for example, V1–V2 or V4) are >200 bp in length in which case PE reads do not overlap. However, it is possible, as we present here, to use non-overlapping PE reads to pick OTUs and build a phylogenetic tree. We assessed the utility of using PE Illumina sequencing, compared with results from single-direction (SD) sequencing from the 5′ position of the V4 region of 16S rRNA genes. We compared alpha- and beta-diversity analyses (species richness and between-sample comparisons, respectively), using previously published non-overlapping PE Illumina sequence data from 16S rRNA gene surveys of 28 human microbiome and environmental samples (Caporaso et al., 2011). Illumina sequences were quality filtered using the default pipeline in QIIME 1.2.1 (Caporaso et al., 2010b), including the default quality thresholds and a minimum read length of 75 bp. To avoid potential biases from quality filtering, only sequences passing the quality threshold in both 5′ and 3′ reads were kept for downstream processing (43% of the total reads were removed because one of the two directions did not pass the quality threshold). All reads were trimmed to 75 bp length (total of 150 bp per seq for PE). The PE and 5′ SD data were analyzed separately, using the default settings in QIIME, with the following additional steps for PE data: before OTU-picking with uclust (97% ID) (Edgar, 2010), we joined PE reads ‘inside-out’ such that the 3′ end of the 3′ read was to the left of the 5′ end of the 5′ read, required for uclust to perform accurate pairwise alignments. Based on a simulation using Greengenes sequences trimmed to the V4 region, we found that uclust assigned similar pairwise alignment distances to inside-out reads compared with the normal configuration (Supplementary Figure S1). OTU representative sequences (separate 3′ and 5′ reads for PE) were aligned with PyNAST (Caporaso et al., 2010a) against separate regions of the August 2007 Greengenes core (DeSantis et al., 2006), trimmed to positions 2250–2423 for 5′ reads and 3805–4069 for 3′ reads. Trimming reference sequences had advantages of rapid computation, more stringent discarding of non-16S reads, and has previously been shown to improve taxonomic classification (Werner et al., 2011b). We built a phylogenetic tree (FastTree) (Price et al., 2010) from aligned, filtered sequences (for PE, the separate 5′ and 3′ alignments were joined end-to-end to use all 150 bp for phylogeny). Separately for each method, we discarded OTUs with fewer than 10 total reads (2.6% of the 16.6 million high-quality reads). This was done to discard false diversity because of sequencing errors, by setting a 10 × threshold of evidence needed to support a true sequence. OTUs that failed to align >72 bp (0.007% of remaining reads) were also removed. We obtained slightly higher alpha-diversity (Chao1) using PE data compared with 5′ SD data, but the results were still comparable (Supplementary Figure S2). Between-sample comparisons of alpha-diversity were consistent, except for the fecal samples, which had greater disagreement. We also observed that the pairing of sequences into the same OTU was least consistent for fecal and soil samples, comparing PE and 5′ SD data (Supplementary Figure S3). We additionally used three beta-diversity metrics to calculate distances between samples in both the PE data and the 5′ SD read data: Bray–Curtis (based on relative abundances of OTUs), unweighted UniFrac (based on phylogenetic structure), and weighted UniFrac (based on phylogenetic structure, weighted by OTU abundances). All three metrics have a scale from 0 to 1. Bray–Curtis distances for OTUs picked based on PE reads vs 5′ SD reads were closely correlated (Supplementary Figure S4A; R2=0.993). Disagreement between absolute distances was below 0.1 (Supplementary Figure S4D), and the UPGMA clustering of samples was comparable between methods (Supplementary Figure S5). Thus, the two OTU-picking strategies resulted in the same beta-diversi

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1038/ismej.2011.186

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 123

Metadata

Authors
Werner, J. J., Zhou, D., Caporaso, J. G., Knight, R., & Angenent, L. T.
Venue
The ISME Journal
Published
2011-12-15
Volume
6
Issue
7
Pages
1273-1276
ISSN
  • 1751-7362 (ISSN-L)
  • 1751-7370
OpenAlex
W1963710004
Cited by
123
References
2
FWCI
3.53
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Comparison of Illumina paired-end and single-direction sequencing for microbial 16S rRNA gene amplicon surveys. https://app.cochat.ai/papers/10.1038/ismej.2011.186
The paper
Werner, J. J., Zhou, D., Caporaso, J. G., Knight, R., & Angenent, L. T. (2012). Comparison of Illumina paired-end and single-direction sequencing for microbial 16S rRNA gene amplicon surveys. The ISME Journal. https://doi.org/10.1038/ismej.2011.186

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.