Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 166

The DOI matches its Crossref record.

A Noninvasive Positron Computed Tomography Technique Using Oxygen-15-Labeled Water for the Evaluation of Neurobehavioral Task Batteries

Mazziotta, John C., Huang, Sung-Cheng, Phelps, Michael E., Carson, Richard E., MacDonald, Norman S., Mahoney, Kirk·1985·Journal of Cerebral Blood Flow & Metabolism

Abstract

A technique is described that provides information about relative cerebral responses to differing neurobehavioral tasks in normal subjects studied with positron computed tomography and oxygen-15-labeled water. Simulation studies demonstrate that this technique is sensitive to changes in true local CBF within a physiological range and tends to underestimate relative flow changes at high flow values (>30 ml min−1 100 g−1) and to overestimate these changes for flow values of <25 ml min−1 100 g−1. Image acquisition times of 60 s following the arrival of oxygen-15-labeled water in the brain were the most accurate for identifying such relative changes between radioisotope administrations and were not limited by statistical noise from total image counts. Studies in normal volunteers indicate that the technique is highly reproducible, demonstrating a coefficient of variation for small (<2 cm 2) regions of 2.98 between studies in the same state. Visual stimulation studies in normal volunteers demonstrated relative radioisotope concentration changes between control and stimulated states that are in good agreement with similar results obtained using the same stimulation paradigm but with the use of fluorodeoxyglucose to determine cerebral glucose metabolism.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1038/jcbfm.1985.10

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 166

Metadata

Authors
Mazziotta, J. C., Huang, S.-C., Phelps, M. E., Carson, R. E., MacDonald, N. S., & Mahoney, K.
Venue
Journal of Cerebral Blood Flow & Metabolism
Published
1985-03
Volume
5
Issue
1
Pages
70-78
ISSN
  • 0271-678X (ISSN-L)
  • 1559-7016
OpenAlex
W2005060853
Cited by
166
References
0
FWCI
4.52
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A Noninvasive Positron Computed Tomography Technique Using Oxygen-15-Labeled Water for the Evaluation of Neurobehavioral Task Batteries. https://app.cochat.ai/papers/10.1038/jcbfm.1985.10
The paper
Mazziotta, J. C., Huang, S.-C., Phelps, M. E., Carson, R. E., MacDonald, N. S., & Mahoney, K. (1985). A Noninvasive Positron Computed Tomography Technique Using Oxygen-15-Labeled Water for the Evaluation of Neurobehavioral Task Batteries. Journal of Cerebral Blood Flow & Metabolism. https://doi.org/10.1038/jcbfm.1985.10

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.