The Retention Mechanism of Technetium-99m-HM-PAO: Intracellular Reaction with Glutathione

Neirinckx, Rudi D., Burke, James F., Harrison, Roger C., Forster, Alan M., Andersen, Allan R., Lassen, Niels A. · 1988 · Journal of Cerebral Blood Flow & Metabolism
Cited by 165

The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.

Abstract

Preparations of d,l- and meso-hexamethylpropyleneamine oxime (HM-PAO) labeled with technetium-99m were added to rat brain homogenates diluted with phosphate buffer (l: 10). The conversion of d,l-HM-PAO to hydrophilic forms took place with an initial rate constant of 0.12 min−1. Incubation of the brain homogenate with 2% diethyl maleate for 5 h decreased the homogenate's measured glutathione (GSH) concentration from 160 to 16 μ M and decreased the conversion rate to 0.012 min−1. Buffered aqueous solutions of glutathione rapidly converted the HM-PAO tracers to hydrophilic forms having the same chromatographic characteristics as found in the brain homogenates. The rate constant for the conversion reaction of d,l-HM-PAO in GSH aqueous solution was 208 and 317 L/mol/min in two different assay systems and for meso-HM-PAO the values were 14.7 and 23.2 L/mol/min, respectively. Rat brain has a GSH concentration of about 2.3 m M and the conversion of the d,l-HM-PAO due to GSH alone should proceed with a rate constant of 0.48 to 0.73 min−1 and be correspondingly 14-fold slower for meso-HM-PAO. In human brain, the in vivo data of Lassen et al. show a conversion rate constant of 0.80 min−1. This correspondence of values supports the notion that GSH may be important for the in vivo conversion of 99m Tc-labeled HM-PAO to hydrophilic forms and may be the mechanism of trapping in brain and other cells. A kinetic model for the trapping of d,l- and meso-HM-PAO in tissue is developed that is based on data of GSH concentration in various organs. This model predicts that the d,l form rapidly reaches a steady state in tissue and the tissue distribution reflects a pattern dominated by blood flow. For the meso form, the model predicts that steady state is reached more slowly and the tissue distribution reflects a pattern dominated by glutathione concentration.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1038/jcbfm.1988.27

Cites

16 of 16 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 16 references

Cited by

Metadata

Authors
Neirinckx, R. D., Burke, J. F., Harrison, R. C., Forster, A. M., Andersen, A. R., & Lassen, N. A.
Venue
Journal of Cerebral Blood Flow & Metabolism
Published
1988-12
Volume
8
Issue
1_suppl
Pages
S4-S12
ISSN
  • 0271-678X (ISSN-L)
  • 1559-7016
OpenAlex
W1987886704
Cited by
165
References
16
FWCI
5.84
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.