The DOI matches its Crossref record.
Cannulation technique influences arteriovenous fistula and graft survival
Open accessAbstract
Hemodialysis patient survival is dependent on the availability of a reliable vascular access. In clinical practice, procedures for vascular access cannulation vary from clinic to clinic. We investigated the impact of cannulation technique on arteriovenous fistula and graft survival. Based on an April 2009 cross-sectional survey of vascular access cannulation practices in 171 dialysis units, a cohort of patients with corresponding vascular access survival information was selected for follow-up ending March 2012. Of the 10,807 patients enrolled in the original survey, access survival data were available for 7058 patients from nine countries. Of these, 90.6% had an arteriovenous fistula and 9.4% arteriovenous graft. Access needling was by area technique for 65.8%, rope-ladder for 28.2%, and buttonhole for 6%. The most common direction of puncture was antegrade with bevel up (43.1%). A Cox regression model was applied, adjusted for within-country effects, and defining as events the need for creation of a new vascular access. Area cannulation was associated with a significantly higher risk of access failure than rope-ladder or buttonhole. Retrograde direction of the arterial needle with bevel down was also associated with an increased failure risk. Patient application of pressure during cannulation appeared more favorable for vascular access longevity than not applying pressure or using a tourniquet. The higher risk of failure associated with venous pressures under 100 or over 150 mm Hg should open a discussion on limits currently considered acceptable.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Schmidli, J., Widmer, M. K., Basile, C., de Donato, G., Gallieni, M., Gibbons, C. P., Haage, P., Hamilton, G., Hedin, U., Kamper, L., et al. (2018) · European Journal of Vascular and Endovascular Surgery · doi:10.1016/j.ejvs.2018.02.001 · Cited by 878
Guía Clínica Española del Acceso Vascular para Hemodiálisis
Ibeas, J., Roca-Tey, R., Vallespín, J., Moreno, T., Moñux, G., Martí-Monrós, A., del Pozo, J. L., Gruss, E., Ramírez de Arellano, M., Fontseré, N., et al. (2017) · Nefrología · doi:10.1016/j.nefro.2017.11.004 · Cited by 214
UK Kidney Association Clinical Practice Guideline on vascular access for haemodialysis
Aitken, E., Anijeet, H., Ashby, D., Barrow, W., Calder, F., Dowds, B., Fielding, C., Gilbert, J., Jones, R., Karunanithy, N., et al. (2025) · BMC Nephrology · doi:10.1186/s12882-025-04374-y · Cited by 42
Staaf, K., Fernström, A., & Uhlin, F. (2021) · BMC Nephrology · doi:10.1186/s12882-021-02458-z · Cited by 26
Multiple single cannulation technique of arteriovenous fistula: a randomized controlled trial
Peralta, R., Fazendeiro Matos, J., Pinto, B., Gonçalves, P., Sousa, R., Felix, C., Carvalho, H., Vinhas, J., & Ponce, P. (2022) · Hemodialysis International · doi:10.1111/hdi.12962 · Cited by 19
Metadata
- Authors
- Parisotto, M. T., Schoder, V. U., Miriunis, C., Grassmann, A. H., Scatizzi, L. P., Kaufmann, P., Stopper, A., & Marcelli, D.
- Venue
- Kidney International
- Publisher
- Elsevier BV
- Published
- 2014-10
- Volume
- 86
- Issue
- 4
- Pages
- 790-797
- ISSN
- 0085-2538 (ISSN-L)
- OpenAlex
- W2169931787
- Cited by
- 169
- References
- 0
- FWCI
- 22.68
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Cannulation technique influences arteriovenous fistula and graft survival. https://app.cochat.ai/papers/10.1038/ki.2014.96
- The paper
- Parisotto, M. T., Schoder, V. U., Miriunis, C., Grassmann, A. H., Scatizzi, L. P., Kaufmann, P., Stopper, A., & Marcelli, D. (2014). Cannulation technique influences arteriovenous fistula and graft survival. Kidney International. https://doi.org/10.1038/ki.2014.96
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.