Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 248

The DOI matches its Crossref record.

A complementary role of multiparameter flow cytometry and high-throughput sequencing for minimal residual disease detection in chronic lymphocytic leukemia: an European Research Initiative on CLL study

Open access
on behalf of ERIC (European Research Initiative on CLL), Rawstron, A C, Fazi, C, Agathangelidis, A, Villamor, N, Letestu, R, Nomdedeu, J, Palacio, C, Stehlikova, O, Kreuzer, K-A, Liptrot, S, O'Brien, D, de Tute, R M, Marinov, I, Hauwel, M, Spacek, M, Dobber, J, Kater, A P, Gambell, P, Soosapilla, A, Lozanski, G, Brachtl, G, Lin, K, Boysen, J, Hanson, C, Jorgensen, J L, Stetler-Stevenson, M, Yuan, C, Broome, H E, Rassenti, L, Craig, F, Delgado, J, Moreno, C, Bosch, F, Egle, A, Doubek, M, Pospisilova, S, Mulligan, S, Westerman, D, Sanders, C M, Emerson, R, Robins, H S, Kirsch, I, Shanafelt, T, Pettitt, A, Kipps, T J, Wierda, W G, Cymbalista, F, Hallek, M, Hillmen, P, Montserrat, E, Ghia, P·2016·Leukemia

Abstract

In chronic lymphocytic leukemia (CLL) the level of minimal residual disease (MRD) after therapy is an independent predictor of outcome. Given the increasing number of new agents being explored for CLL therapy, using MRD as a surrogate could greatly reduce the time necessary to assess their efficacy. In this European Research Initiative on CLL (ERIC) project we have identified and validated a flow-cytometric approach to reliably quantitate CLL cells to the level of 0.0010% (10(-5)). The assay comprises a core panel of six markers (i.e. CD19, CD20, CD5, CD43, CD79b and CD81) with a component specification independent of instrument and reagents, which can be locally re-validated using normal peripheral blood. This method is directly comparable to previous ERIC-designed assays and also provides a backbone for investigation of new markers. A parallel analysis of high-throughput sequencing using the ClonoSEQ assay showed good concordance with flow cytometry results at the 0.010% (10(-4)) level, the MRD threshold defined in the 2008 International Workshop on CLL guidelines, but it also provides good linearity to a detection limit of 1 in a million (10(-6)). The combination of both technologies would permit a highly sensitive approach to MRD detection while providing a reproducible and broadly accessible method to quantify residual disease and optimize treatment in CLL.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1038/leu.2015.313

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 248

Metadata

Authors
CLL), O. B. O. E. (. R. I. O., Rawstron, A. C., Fazi, C., Agathangelidis, A., Villamor, N., Letestu, R., Nomdedeu, J., Palacio, C., Stehlikova, O., Kreuzer, K.-A., Liptrot, S., O'Brien, D., de Tute, R. M., Marinov, I., Hauwel, M., Spacek, M., Dobber, J., Kater, A. P., Gambell, P., Soosapilla, A., Lozanski, G., Brachtl, G., Lin, K., Boysen, J., Hanson, C., Jorgensen, J. L., Stetler-Stevenson, M., Yuan, C., Broome, H. E., Rassenti, L., Craig, F., Delgado, J., Moreno, C., Bosch, F., Egle, A., Doubek, M., Pospisilova, S., Mulligan, S., Westerman, D., Sanders, C. M., Emerson, R., Robins, H. S., Kirsch, I., Shanafelt, T., Pettitt, A., Kipps, T. J., Wierda, W. G., Cymbalista, F., Hallek, M., Hillmen, P., Montserrat, E., & Ghia, P.
Venue
Leukemia
Published
2015-12-07
Volume
30
Issue
4
Pages
929-936
ISSN
  • 0887-6924 (ISSN-L)
  • 1476-5551
OpenAlex
W2193060933
Cited by
248
References
0
FWCI
8.48
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A complementary role of multiparameter flow cytometry and high-throughput sequencing for minimal residual disease detection in chronic lymphocytic leukemia: an European Research Initiative on CLL study. https://app.cochat.ai/papers/10.1038/leu.2015.313
The paper
CLL), O. B. O. E. (. R. I. O., Rawstron, A. C., Fazi, C., Agathangelidis, A., Villamor, N., Letestu, R., Nomdedeu, J., Palacio, C., Stehlikova, O., Kreuzer, K.-A., Liptrot, S., O'Brien, D., de Tute, R. M., Marinov, I., Hauwel, M., Spacek, M., Dobber, J., Kater, A. P., Gambell, P., . . . Ghia, P. (2016). A complementary role of multiparameter flow cytometry and high-throughput sequencing for minimal residual disease detection in chronic lymphocytic leukemia: an European Research Initiative on CLL study. Leukemia. https://doi.org/10.1038/leu.2015.313

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.