Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 170

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

A paper-based microfluidic biosensor integrating zinc oxide nanowires for electrochemical glucose detection

Open access
Li, Xiao, Zhao, Chen, Liu, Xinyu·2015·Microsystems & Nanoengineering

Abstract

This paper reports an electrochemical microfluidic paper-based analytical device (EμPAD) for glucose detection, featuring a highly sensitive working electrode (WE) decorated with zinc oxide nanowires (ZnO NWs). In addition to the common features of μPADs, such as their low costs, high portability/disposability, and ease of operation, the reported EμPAD has three further advantages. (i) It provides higher sensitivity and a lower limit of detection (LOD) than previously reported μPADs because of the high surface-to-volume ratio and high enzyme-capturing efficiency of the ZnO NWs. (ii) It does not need any light-sensitive electron mediator (as is usually required in enzymatic glucose sensing), which leads to enhanced biosensing stability. (iii) The ZnO NWs are directly synthesized on the paper substrate via low-temperature hydrothermal growth, representing a simple, low-cost, consistent, and mass-producible process. To achieve superior analytical performance, the on-chip stored enzyme (glucose oxidase) dose and the assay incubation time are tuned. More importantly, the critical design parameters of the EμPAD, including the WE area and the ZnO-NW growth level, are adjusted to yield tunable ranges for the assay sensitivity and LOD. The highest sensitivity that we have achieved is 8.24 μA·mM−1·cm−2, with a corresponding LOD of 59.5 μM. By choosing the right combination of design parameters, we constructed EμPADs that cover the range of clinically relevant glucose concentrations (0−15 mM) and fully calibrated these devices using spiked phosphate-buffered saline and human serum. We believe that the reported approach for integrating ZnO NWs on EμPADs could be well utilized in many other designs of EμPADs and provides a facile and inexpensive paradigm for further enhancing the device performance.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1038/micronano.2015.14

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 170

Metadata

Authors
Li, X., Zhao, C., & Liu, X.
Venue
Microsystems & Nanoengineering
Published
2015-08-03
Volume
1
Issue
1
ISSN
2055-7434 (ISSN-L)
OpenAlex
W2679333672
Cited by
170
References
1
FWCI
7.86
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.