The DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Preparation and detection of a mechanical resonator near the ground state of motion
Open accessAbstract
Cold, macroscopic mechanical systems are expected to behave contrary to our usual classical understanding of reality; the most striking and counterintuitive predictions involve the existence of states in which the mechanical system is located in two places simultaneously. Various schemes have been proposed to generate and detect such states, and all require starting from mechanical states that are close to the lowest energy eigenstate, the mechanical ground state. Here we report the cooling of the motion of a radio-frequency nanomechanical resonator by parametric coupling to a driven, microwave-frequency superconducting resonator. Starting from a thermal occupation of 480 quanta, we have observed occupation factors as low as 3.8 ± 1.3 and expect the mechanical resonator to be found with probability 0.21 in the quantum ground state of motion. Further cooling is limited by random excitation of the microwave resonator and heating of the dissipative mechanical bath. This level of cooling is expected to make possible a series of fundamental quantum mechanical observations including direct measurement of the Heisenberg uncertainty principle and quantum entanglement with qubits.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A broadband superconducting detector suitable for use in large arrays
Day, P. K., LeDuc, H. G., Mazin, B. A., Vayonakis, A., & Zmuidzinas, J. (2003) · Nature · doi:10.1038/nature02037 · Cited by 1,380
Quantum Theory of Cavity-Assisted Sideband Cooling of Mechanical Motion
Marquardt, F., Chen, J. P., Clerk, A. A., & Girvin, S. M. (2007) · Physical Review Letters · doi:10.1103/physrevlett.99.093902 · Cited by 1,146
Self-citationTheory of Ground State Cooling of a Mechanical Oscillator Using Dynamical Backaction
Wilson-Rae, I., Nooshi, N., Zwerger, W., & Kippenberg, T. J. (2007) · Physical Review Letters · doi:10.1103/physrevlett.99.093901 · Cited by 993
Towards quantum superpositions of a mirror
Marshall, W., Simon, C., Penrose, R., & Bouwmeester, D. (2003) · Physical Review Letters · doi:10.1103/physrevlett.91.130401 · Cited by 960
Laser Cooling to the Zero-Point Energy of Motion
Diedrich, F., Bergquist, J. C., Itano, W. M., & Wineland, D. J. (1989) · Physical Review Letters · doi:10.1103/physrevlett.62.403 · Cited by 793
Amplification and squeezing of quantum noise with a tunable Josephson metamaterial
Castellanos-Beltran, M. A., Irwin, K. D., Hilton, G. C., Vale, L. R., & Lehnert, K. W. (2008) · Nature Physics · doi:10.1038/nphys1090 · Cited by 632
Cooling a nanomechanical resonator with quantum back-action
Naik, A., Buu, O., LaHaye, M. D., Armour, A. D., Clerk, A. A., Blencowe, M. P., & Schwab, K. C. (2006) · Nature · doi:10.1038/nature05027 · Cited by 543
Self-citationA nanometre-scale mechanical electrometer
Cleland, A. N., & Roukes, M. L. (1998) · Nature · doi:10.1038/32373 · Cited by 512
Measuring nanomechanical motion with a microwave cavity interferometer
Regal, C. A., Teufel, J. D., & Lehnert, K. W. (2008) · Nature Physics · doi:10.1038/nphys974 · Cited by 500
Entanglement and Decoherence of a Micromechanical Resonator via Coupling to a Cooper-Pair Box
Armour, A. D., Blencowe, M. P., & Schwab, K. C. (2002) · Physical Review Letters · doi:10.1103/physrevlett.88.148301 · Cited by 464
Self-citationSchliesser, A., Arcizet, O., Rivière, R., Anetsberger, G., & Kippenberg, T. J. (2009) · Nature Physics · doi:10.1038/nphys1304 · Cited by 438
Feedback Cooling of a Cantilever’s Fundamental Mode below 5 mK
Poggio, M., Degen, C. L., Mamin, H. J., & Rugar, D. (2007) · Physical Review Letters · doi:10.1103/physrevlett.99.017201 · Cited by 371
Demonstration of an ultracold micro-optomechanical oscillator in a cryogenic cavity
Gröblacher, S., Hertzberg, J. B., Vanner, M. R., Cole, G. D., Gigan, S., Schwab, K. C., & Aspelmeyer, M. (2009) · Nature Physics · doi:10.1038/nphys1301 · Cited by 338
Self-citationParametric Normal-Mode Splitting in Cavity Optomechanics
Dobrindt, J. M., Wilson-Rae, I., & Kippenberg, T. J. (2008) · Physical Review Letters · doi:10.1103/physrevlett.101.263602 · Cited by 326
Noncontact Friction and Force Fluctuations between Closely Spaced Bodies
Stipe, B. C., Mamin, H. J., Stowe, T. D., Kenny, T. W., & Rugar, D. (2001) · Physical Review Letters · doi:10.1103/physrevlett.87.096801 · Cited by 321
Resolved-sideband and cryogenic cooling of an optomechanical resonator
Park, Y.-S., & Wang, H. (2009) · Nature Physics · doi:10.1038/nphys1303 · Cited by 301
Dynamical Backaction of Microwave Fields on a Nanomechanical Oscillator
Teufel, J. D., Harlow, J., Regal, C. A., & Lehnert, K. W. (2008) · Physical Review Letters · doi:10.1103/physrevlett.101.197203 · Cited by 221
A megahertz nanomechanical resonator with room temperature quality factor over a million
Verbridge, S. S., Craighead, H. G., & Parpia, J. M. (2008) · Applied Physics Letters · doi:10.1063/1.2822406 · Cited by 203
Ground-state cooling of mechanical resonators
Martin, I., Shnirman, A., Tian, L., & Zoller, P. (2004) · Physical Review B · doi:10.1103/physrevb.69.125339 · Cited by 181
High Sensitivity Gravitational Wave Antenna with Parametric Transducer Readout
Blair, D. G., Ivanov, E. N., Tobar, M. E., Turner, P., van Kann, F. J., & Heng, I. S. (1995) · Physical Review Letters · doi:10.1103/physrevlett.74.1908 · Cited by 181
Quantum limits of cold damping with optomechanical coupling
Courty, J.-M., Heidmann, A., & Pinard, M. (2001) · The European Physical Journal D · doi:10.1007/s100530170014 · Cited by 90
Quantum limits of cold damping with optomechanical coupling
Courty, J.-M., Heidmann, A., & Pinard, M. (2001) · HAL (Le Centre pour la Communication Scientifique Directe) · Cited by 62
Prospects for cooling nanomechanical motion by coupling to a superconducting microwave resonator
Teufel, J. D., Regal, C. A., & Lehnert, K. W. (2008) · New Journal of Physics · doi:10.1088/1367-2630/10/9/095002 · Cited by 61
Cooling a micromechanical beam by coupling it to a transmission line
Xue, F., Wang, Y. D., Liu, Y.-X., & Nori, F. (2007) · Physical Review B · doi:10.1103/physrevb.76.205302 · Cited by 59
Quantum analysis of a linear dc SQUID mechanical displacement detector
Blencowe, M. P., & Buks, E. (2007) · Physical Review B · doi:10.1103/physrevb.76.014511 · Cited by 57
Lower limit on the achievable temperature in resonator-based sideband cooling
Grajcar, M., Ashhab, S., Johansson, J. R., & Nori, F. (2008) · Physical Review B · doi:10.1103/physrevb.78.035406 · Cited by 50
Cited by
Aspelmeyer, M., Kippenberg, T. J., & Marquardt, F. (2014) · Reviews of Modern Physics · doi:10.1103/revmodphys.86.1391 · Cited by 5,501
Laser cooling of a nanomechanical oscillator into its quantum ground state
Chan, J., Alegre, T. P. M., Safavi-Naeini, A. H., Hill, J. T., Krause, A., Gröblacher, S., Aspelmeyer, M., & Painter, O. (2011) · Nature · doi:10.1038/nature10461 · Cited by 2,311
Sideband cooling of micromechanical motion to the quantum ground state
Teufel, J. D., Donner, T., Li, D., Harlow, J. W., Allman, M. S., Cicak, K., Sirois, A. J., Whittaker, J. D., Lehnert, K. W., & Simmonds, R. W. (2011) · Nature · doi:10.1038/nature10261 · Cited by 2,089
Quantum ground state and single-phonon control of a mechanical resonator
O’Connell, A. D., Hofheinz, M., Ansmann, M., Bialczak, R. C., Lenander, M., Lucero, E., Neeley, M., Sank, D., Wang, H., Weides, M., et al. (2010) · Nature · doi:10.1038/nature08967 · Cited by 1,959
Electromagnetically induced transparency and slow light with optomechanics
Safavi-Naeini, A. H., Alegre, T. P. M., Chan, J., Eichenfield, M., Winger, M., Lin, Q., Hill, J. T., Chang, D. E., & Painter, O. (2011) · Nature · doi:10.1038/nature09933 · Cited by 1,456
Metadata
- Authors
- Rocheleau, T., Ndukum, T., Macklin, C., Hertzberg, J. B., Clerk, A. A., & Schwab, K. C.
- Venue
- Nature
- Published
- 2009-12-09
- Volume
- 463
- Issue
- 7277
- Pages
- 72-75
- ISSN
- 0028-0836 (ISSN-L)
- 1476-4687
- OpenAlex
- W2004098727
- Cited by
- 506
- References
- 26
- FWCI
- 33.64
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.