The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Room-temperature solid-state maser
Abstract
The invention of the laser has resulted in many innovations, and the device has become ubiquitous. However, the maser, which amplifies microwave radiation rather than visible light, has not had as large an impact, despite being instrumental in the laser’s birth. The maser’s relative obscurity has mainly been due to the inconvenience of the operating conditions needed for its various realizations: atomic and free-electron masers require vacuum chambers and pumping; and solid-state masers, although they excel as low-noise amplifiers and are occasionally incorporated in ultrastable oscillators, typically require cryogenic refrigeration. Most realizations of masers also require strong magnets, magnetic shielding or both. Overcoming these various obstacles would pave the way for improvements such as more-sensitive chemical assays, more-precise determinations of biomolecular structure and function, and more-accurate medical diagnostics (including tomography) based on enhanced magnetic resonance spectrometers incorporating maser amplifiers and oscillators. Here we report the experimental demonstration of a solid-state maser operating at room temperature in pulsed mode. It works on a laboratory bench, in air, in the terrestrial magnetic field and amplifies at around 1.45 gigahertz. In contrast to the cryogenic ruby maser, in our maser the gain medium is an organic mixed molecular crystal, p-terphenyl doped with pentacene, the latter being photo-excited by yellow light. The maser’s pumping mechanism exploits spin-selective molecular intersystem crossing into pentacene’s triplet ground state. When configured as an oscillator, the solid-state maser’s measured output power of around −10 decibel milliwatts is approximately 100 million times greater than that of an atomic hydrogen maser, which oscillates at a similar frequency (about 1.42 gigahertz). By exploiting the high levels of spin polarization readily generated by intersystem crossing in photo-excited pentacene and other aromatic molecules, this new type of maser seems to be capable of amplifying with a residual noise temperature far below room temperature.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A New Look at the Saturn System: The Voyager 2 Images
Smith, B. A., Soderblom, L., Batson, R., Bridges, P., Inge, J., Masursky, H., Shoemaker, E., Beebe, R., Boyce, J., Briggs, G., et al. (1982) · Science · doi:10.1126/science.215.4532.504 · Cited by 848
Cited by
Optically addressable molecular spins for quantum information processing
Bayliss, S. L., Laorenza, D. W., Mintun, P. J., Kovos, B. D., Freedman, D. E., & Awschalom, D. D. (2020) · Science · doi:10.1126/science.abb9352 · Cited by 348
Room-temperature quantum microwave emitters based on spin defects in silicon carbide
Kraus, H., Soltamov, V. A., Riedel, D., Väth, S., Fuchs, F., Sperlich, A., Baranov, P. G., Dyakonov, V., & Astakhov, G. V. (2014) · Nature Physics · doi:10.1038/nphys2826 · Cited by 254
Ritchie, M. D., Rowan, S., Kucera, G., Stubblefield, T., Blair, M., Carter, S., Roden, D. M., & Darbar, D. (2012) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2012.04.030 · Cited by 91
Metadata
- Authors
- Oxborrow, M., Breeze, J. D., & Alford, N. M.
- Venue
- Nature
- Published
- 2012-08
- Volume
- 488
- Issue
- 7411
- Pages
- 353-356
- ISSN
- 0028-0836 (ISSN-L)
- 1476-4687
- OpenAlex
- W1965698612
- Cited by
- 169
- References
- 1
- FWCI
- 3.86
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Room-temperature solid-state maser. https://app.cochat.ai/papers/10.1038/nature11339
- The paper
- Oxborrow, M., Breeze, J. D., & Alford, N. M. (2012). Room-temperature solid-state maser. Nature. https://doi.org/10.1038/nature11339
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.