The DOI matches its Crossref record; 33 of the 33 references it cites were found in a registry or an index.
Energy extraction from the biologic battery in the inner ear
Open accessAbstract
Endocochlear potential (EP) is a battery-like electrochemical gradient found in and actively maintained by the inner ear. Here we demonstrate that the mammalian EP can be used as a power source for electronic devices. We achieved this by designing an anatomically sized, ultra-low quiescent-power energy harvester chip integrated with a wireless sensor capable of monitoring the EP itself. Although other forms of in vivo energy harvesting have been described in lower organisms, and thermoelectric, piezoelectric and biofuel devices are promising for mammalian applications, there have been few, if any, in vivo demonstrations in the vicinity of the ear, eye and brain. In this work, the chip extracted a minimum of 1.12 nW from the EP of a guinea pig for up to 5 h, enabling a 2.4 GHz radio to transmit measurement of the EP every 40–360 s. With future optimization of electrode design, we envision using the biologic battery in the inner ear to power chemical and molecular sensors, or drug-delivery actuators for diagnosis and therapy of hearing loss and other disorders.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“However, these methods are anatomically specific and, in their existing forms, yield power densities too low (<0.1 μW/mm 2 ) for a microimplant.”
From Wireless power transfer to deep-tissue microimplants (2014) · cites this paper as [8]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Enhanced thermoelectric performance of rough silicon nanowires
Hochbaum, A. I., Chen, R., Delgado, R. D., Liang, W., Garnett, E. C., Najarian, M., Majumdar, A., & Yang, P. (2008) · Nature · doi:10.1038/nature06381 · Cited by 4,109
Leakage current mechanisms and leakage reduction techniques in deep-submicrometer CMOS circuits
Roy, K., Mukhopadhyay, S. C., & Mahmoodi, H. (2003) · Proceedings of the IEEE · doi:10.1109/jproc.2002.808156 · Cited by 2,394
Microfibre–nanowire hybrid structure for energy scavenging
Qin, Y., Wang, X., & Wang, Z. L. (2008) · Nature · doi:10.1038/nature06601 · Cited by 1,605
Electricity generation by direct oxidation of glucose in mediatorless microbial fuel cells
Chaudhuri, S. K., & Lovley, D. R. (2003) · Nature Biotechnology · doi:10.1038/nbt867 · Cited by 1,579
Biofuel cells and their development
Bullen, R. A., Arnot, T., Lakeman, J. B., & Walsh, F. C. (2006) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2006.01.030 · Cited by 1,012
Biomechanical Energy Harvesting: Generating Electricity During Walking with Minimal User Effort
Donelan, J. M., Li, Q., Naing, V., Hoffer, J. A., Weber, D. J., & Kuo, A. D. (2008) · Science · doi:10.1126/science.1149860 · Cited by 777
A Battery-Less Thermoelectric Energy Harvesting Interface Circuit With 35 mV Startup Voltage
Ramadass, Y. K., & Chandrakasan, A. P. (2010) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2010.2074090 · Cited by 584
Self-citationImplanted Biofuel Cell Operating in a Living Snail
Halámková, L., Halámek, J., Bocharova, V., Szczupak, A., Alfonta, L., & Katz, E. (2012) · Journal of the American Chemical Society · doi:10.1021/ja211714w · Cited by 486
Ion-implanted complementary MOS transistors in low-voltage circuits
Swanson, R. M., & MEINDL, J. D. (1972) · Digest of technical papers/Digest of technical papers - IEEE International Solid-State Circuits Conference · doi:10.1109/isscc.1972.1155118 · Cited by 322
An Implantable Biofuel Cell for a Live Insect
Rasmussen, M., Ritzmann, R. E., Lee, I., Pollack, A. J., & Scherson, D. A. (2012) · Journal of the American Chemical Society · doi:10.1021/ja210794c · Cited by 271
Flagged first, then by citations
Cited by
Sorted by citations
Items 201–217 of 217
Selected Papers from the 8th Symposium on Micro-Nano Science and Technology on Micromachines
Miki, N., Miyazaki, K., & Morimoto, Y. (2019) · MDPI eBooks · doi:10.3390/books978-3-03897-729-2
Lu, S. (2021) · UWA Profiles and Research Repository (UWA) · doi:10.26182/cvwm-fz12
Emerging Technologies for Mobile Health
Karathanasis, K. T., & Nikita, K. S. (2017) · CRC Press eBooks · doi:10.1201/9781315155821-15
Yang, G. (2018) · Springer eBooks · doi:10.1007/978-3-319-69748-2_1
Design of mm-Sized Wirelessly Powered Sensors
Bolus, J. F. (2014) · doi:10.18130/v3xf9k
Yılmaz, G., & Dehollain, C. (2017) · Analog circuits and signal processing/Analog circuits and signal processing series · doi:10.1007/978-3-319-49337-4_1
Implantable Piezoelectric Energy Harvesters
(2022) · Wiley eBooks · doi:10.1002/9783527833115.ch9
Emerging in vivo power supply strategies for implantable electronics
Tao, Z., Wang, B., & Wang, Y. (2022) · International Conference on Computer, Artificial Intelligence and Control Engineering (CAICE) · doi:10.1117/12.2641930
Saxena, N., Sharma, M. D., Sharma, R., & Periasamy, C. (2023) · International Conference on Next Generation Electronics (NELEX) · doi:10.1109/nelex59773.2023.10421621
Saha, A., & Alam, M. A. (2024) · ACS Applied Energy Materials · doi:10.1021/acsaem.4c02320
Cochlear Implants: Future Directions
Kara, E., Çögen, T., & Rubinstein, J. T. (2024) · Comprehensive ENT · doi:10.1007/978-3-031-77370-9_28
Teepe, G., Thayyil, M. V., Joram, N., Drechsel, T., Noszczyk-Nowak, A., Frydrychowski, P., Lewicki, M., Prządka, P., Reidy, P., Budny, J., et al. (2025) · Heart Rhythm · doi:10.1016/j.hrthm.2025.06.003
Intelligent implantable devices
Xiong, F., Deng, S., Fu, J., Gao, Q., Wang, J., & Li, S. (2025) · Elsevier eBooks · doi:10.1016/b978-0-443-30142-1.00008-0
TIRA: Task-Based Intermittent Remote Attestation
Arkannezhad, F., & Sehatbakhsh, N. (2026) · doi:10.1145/3774906.3802751
Park, J., Jo, Y. J., Kwon, Y. H., & Kim, S. (2026) · Advanced Electronic Materials · doi:10.1002/aelm.70550
Design guidelines for body-conformable aqueous zinc-based batteries
Li, X., Chen, Y., & Zhou, J. (2026) · Chemical Society Reviews · doi:10.1039/d6cs00347h
Metadata
- Authors
- Mercier, P. P., Lysaght, A. C., Bandyopadhyay, S., Chandrakasan, A. P., & Stankovic, K. M.
- Affiliations
- University of California San Diego (US)
- Massachusetts Eye and Ear Infirmary (US)
- Massachusetts Institute of Technology (US)
- Corresponding author
- Chandrakasan, Anantha P
- Venue
- Nature Biotechnology
- Published
- 2012-11-08
- Volume
- 30
- Issue
- 12
- Pages
- 1240-1243
- ISSN
- 0733-222X (ISSN-L)
- 1087-0156
- 1546-1696
- PMC
- PMC3938019
- OpenAlex
- W1969081205
- Semantic Scholar
- c38cf0e394da70450cfde571d9f6dd4bba0fbfc1
- Cited by
- 217
- References
- 33
- Citations by year
- 2026: 5 · 2025: 7 · 2024: 16 · 2023: 9 · 2022: 13 · 2021: 19 · 2020: 16 · 2019: 13 · 2018: 18 · 2017: 27 · 2016: 16 · 2015: 21 · 2014: 24 · 2013: 11 · 2012: 2
- FWCI
- 28.39
- Type
- journal article
- Language
- en
- Open access
- green
- europepmc.org
- Licence
- www.springer.com/tdm (tdm)
- Locations
- Nature Biotechnology (publishedVersion)
- PubMed (publishedVersion)
- Europe PMC (PubMed Central) (acceptedVersion)
- PubMed Central (acceptedVersion)
- Funders
- National Institute on Deafness and Other Communication Disorders (T32-DC-00038, K08DC010419, T32DC000038)
- Topics
- Physical Sciences › Engineering › Mechanical Engineering › Innovative Energy Harvesting Technologies
- Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
- Physical Sciences › Engineering › Biomedical Engineering › Wireless Body Area Networks
- Keywords
- endocochlear potential, inner ear, wireless sensors, guinea pig, hearing loss, molecular sensors
- MeSH terms
- Animals, Bioelectric Energy Sources, Biotechnology, Cochlear Microphonic Potentials, Electronics, Medical, Equipment Design, Guinea Pigs, Ear, Inner, Electrophysiological Phenomena
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review