Cited by 346Advanced Proteomics Techniques and ApplicationsMass Spectrometry Techniques and ApplicationsMetabolomics and Mass Spectrometry Studies

A multicenter study benchmarks software tools for label-free proteome quantification

Open access
Navarro, Pedro, Kuharev, Jörg, Gillet, Ludovic C, Bernhardt, Oliver M, MacLean, Brendan, Röst, Hannes L, Tate, Stephen A, Tsou, Chih-Chiang +7 more·2016·Nature Biotechnology

Abstract

Consistent and accurate quantification of proteins by mass spectrometry (MS)-based proteomics depends on the performance of instruments, acquisition methods and data analysis software. In collaboration with the software developers, we evaluated OpenSWATH, SWATH 2.0, Skyline, Spectronaut and DIA-Umpire, five of the most widely used software methods for processing data from sequential window acquisition of all theoretical fragment-ion spectra (SWATH)-MS, which uses data-independent acquisition (DIA) for label-free protein quantification. We analyzed high-complexity test data sets from hybrid proteome samples of defined quantitative composition acquired on two different MS instruments using different SWATH isolation-window setups. For consistent evaluation, we developed LFQbench, an R package, to calculate metrics of precision and accuracy in label-free quantitative MS and report the identification performance, robustness and specificity of each software tool. Our reference data sets enabled developers to improve their software tools. After optimization, all tools provided highly convergent identification and reliable quantification performance, underscoring their robustness for label-free quantitative proteomics.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1038/nbt.3685

Cites

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • A recent study comparing software tools for DIA data using peptide-centric or spectrum-centric approaches demonstrated very similar qualitative and quantitative results on a benchmarking data set.

    “A recent study comparing software tools for the analysis of DIA data using either peptide-centric or spectrum-centric approaches has demonstrated that very similar qualitative and quantitative results can be obtained when analyzing a benchmarking data set39.”
  • The result of this study, focused on assessing variation in data acquisition, is paralleled by concurrent improvements in robustness of data analysis tools, methods for error rate control, and sample preparation techniques.

    “The result of our study, focused on assessing variation in data acquisition, is paralleled by concurrent improvements in the robustness of data analysis tools39, methods for error rate control55, and sample preparation techniques43.”

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

The citation lists haven’t been fetched yet

References 49 · Cited by 346

Authors
Navarro, P., Kuharev, J., Gillet, L. C., Bernhardt, O. M., MacLean, B., Röst, H. L., Tate, S. A., Tsou, C.-C., Reiter, L., Distler, U., Rosenberger, G., Perez-Riverol, Y., Nesvizhskii, A. I., Aebersold, R., & Tenzer, S.
Affiliations
  • University Medical Center of the Johannes Gutenberg University Mainz (DE)
  • ETH Zurich (CH)
  • Biognosys (Switzerland) (CH)
  • University of Washington (US)
  • University of Michigan (US)
  • University of Zurich (CH)
Corresponding author
  • Navarro, Pedro
  • Tenzer, Stefan
Venue
Nature Biotechnology
Published
2016-10-03
Volume
34
Issue
11
Pages
1130-1136
ISSN
  • 0733-222X (ISSN-L)
  • 1087-0156
  • 1546-1696
OpenAlex
W2529750106
Cited by
346
References
49
Citations by year
2026: 22 · 2025: 24 · 2024: 23 · 2023: 43 · 2022: 39 · 2021: 48 · 2020: 48 · 2019: 40 · 2018: 32 · 2017: 24 · 2016: 2 · 2014: 1
FWCI
16.28
Type
journal article
Language
en
Open access
Locations
  • Nature Biotechnology (publishedVersion)
  • PubMed (publishedVersion)
  • Europe PMC (PubMed Central) (acceptedVersion)
  • PubMed Central (acceptedVersion)
Funders
  • Schweizerischer Nationalfonds zur Förderung der Wissenschaftlichen Forschung (166435, 162268)
  • Biotechnology and Biological Sciences Research Council (BB/K01997X/1)
  • National Institute of General Medical Sciences (R01GM094231)
Topics
  • Physical Sciences › Chemistry › Spectroscopy › Advanced Proteomics Techniques and Applications
  • Physical Sciences › Chemistry › Spectroscopy › Mass Spectrometry Techniques and Applications
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Metabolomics and Mass Spectrometry Studies
Keywords
label-free quantitative proteomics, SWATH-MS, data-independent acquisition, software benchmarking, skyline, Spectronaut
MeSH terms
Algorithms, Sensitivity and Specificity, Software, Mass Spectrometry, Staining and Labeling, Reproducibility of Results, Benchmarking, Proteome, Internationality

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review