The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Long time-lapse nanoscopy with spontaneously blinking membrane probes
Open accessAbstract
Imaging cellular structures and organelles in living cells by long time-lapse super-resolution microscopy is challenging, as it requires dense labeling, bright and highly photostable dyes, and non-toxic conditions. We introduce a set of high-density, environment-sensitive (HIDE) membrane probes, based on the membrane-permeable silicon-rhodamine dye HMSiR, that assemble in situ and enable long time-lapse, live-cell nanoscopy of discrete cellular structures and organelles with high spatiotemporal resolution. HIDE-enabled nanoscopy movies span tens of minutes, whereas movies obtained with labeled proteins span tens of seconds. Our data reveal 2D dynamics of the mitochondria, plasma membrane and filopodia, and the 2D and 3D dynamics of the endoplasmic reticulum, in living cells. HIDE probes also facilitate acquisition of live-cell, two-color, super-resolution images, expanding the utility of nanoscopy to visualize dynamic processes and structures in living cells.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hell, S. W. (2007) · Science · doi:10.1126/science.1137395 · Cited by 2,967
Cited by
Super-resolution microscopy demystified
Schermelleh, L., Ferrand, A., Huser, T., Eggeling, C., Sauer, M., Biehlmaier, O., & Drummen, G. P. C. (2019) · Nature Cell Biology · doi:10.1038/s41556-018-0251-8 · Cited by 1,211
Single-molecule localization microscopy
Lelek, M., Gyparaki, M. T., Beliu, G., Schueder, F., Griffié, J., Manley, S., Jungmann, R., Sauer, M., Lakadamyali, M., & Zimmer, C. (2021) · Nature Reviews Methods Primers · doi:10.1038/s43586-021-00038-x · Cited by 954
Fast, long-term, super-resolution imaging with Hessian structured illumination microscopy
Huang, X., Fan, J., Li, L., Liu, H., Wu, R., Wu, Y., Wei, L., Mao, H., Lal, A., Xi, P., et al. (2018) · Nature Biotechnology · doi:10.1038/nbt.4115 · Cited by 661
Self-citationSmall-Molecule Fluorescent Probes for Live-Cell Super-Resolution Microscopy
Wang, L., Frei, M. S., Salim, A., & Johnsson, K. (2019) · Journal of the American Chemical Society · doi:10.1021/jacs.8b11134 · Cited by 504
Switchable Fluorophores for Single-Molecule Localization Microscopy
Li, H., & Vaughan, J. C. (2018) · Chemical Reviews · doi:10.1021/acs.chemrev.7b00767 · Cited by 319
Metadata
- Authors
- Takakura, H., Zhang, Y., Erdmann, R. S., Thompson, A. D., Lin, Y., McNellis, B., Rivera-Molina, F., Uno, S.-N., Kamiya, M., Urano, Y., Rothman, J. E., Bewersdorf, J., Schepartz, A., & Toomre, D.
- Venue
- Nature Biotechnology
- Published
- 2017-07-03
- Volume
- 35
- Issue
- 8
- Pages
- 773-780
- ISSN
- 0733-222X (ISSN-L)
- 1087-0156
- 1546-1696
- OpenAlex
- W2732014308
- Cited by
- 194
- References
- 1
- FWCI
- 11.54
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Long time-lapse nanoscopy with spontaneously blinking membrane probes. https://app.cochat.ai/papers/10.1038/nbt.3876
- The paper
- Takakura, H., Zhang, Y., Erdmann, R. S., Thompson, A. D., Lin, Y., McNellis, B., Rivera-Molina, F., Uno, S.-N., Kamiya, M., Urano, Y., Rothman, J. E., Bewersdorf, J., Schepartz, A., & Toomre, D. (2017). Long time-lapse nanoscopy with spontaneously blinking membrane probes. Nature Biotechnology. https://doi.org/10.1038/nbt.3876
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.