ClampFISH detects individual nucleic acid molecules using click chemistry–based amplification
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Methods for detecting single nucleic acids in cell and tissues, such as fluorescence in situ hybridization (FISH), are limited by relatively low signal intensity and nonspecific probe binding. Here we present click-amplifying FISH (clampFISH), a method for fluorescence detection of nucleic acids that achieves high specificity and high-gain (>400-fold) signal amplification. ClampFISH probes form a 'C' configuration upon hybridization to the sequence of interest in a double helical manner. The ends of the probes are ligated together using bio-orthogonal click chemistry, effectively locking the probes around the target. Iterative rounds of hybridization and click amplify the fluorescence intensity. We show that clampFISH enables the detection of RNA species with low-magnification microscopy and in RNA-based flow cytometry. Additionally, we show that the modular design of clampFISH probes allows multiplexing of RNA and DNA detection, that the locking mechanism prevents probe detachment in expansion microscopy, and that clampFISH can be applied in tissue samples.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Imaging individual mRNA molecules using multiple singly labeled probes
Raj, A., van den Bogaard, P., Rifkin, S. A., van Oudenaarden, A., & Tyagi, S. (2008) · Nature Methods · doi:10.1038/nmeth.1253 · Cited by 2,028
Self-citationVisualization of Single RNA Transcripts in Situ
Femino, A. M., Fay, F. S., Fogarty, K., & Singer, R. H. (1998) · Science · doi:10.1126/science.280.5363.585 · Cited by 1,504
Cited by
Bressan, D., Battistoni, G., & Hannon, G. J. (2023) · Science · doi:10.1126/science.abq4964 · Cited by 594
Spatial profiling technologies illuminate the tumor microenvironment
Elhanani, O., Ben-Uri, R., & Keren, L. (2023) · Cancer Cell · doi:10.1016/j.ccell.2023.01.010 · Cited by 510
Highly multiplexed in situ protein imaging with signal amplification by Immuno-SABER
Saka, S. K., Wang, Y., Kishi, J. Y., Zhu, A., Zeng, Y., Xie, W., Kirli, K., Yapp, C., Cicconet, M., Beliveau, B. J., et al. (2018) · doi:10.1101/507566 · Cited by 485
“Hence, in situ analysis with highly multiplexed microscopy imaging methods such as Fluorescence in situ Sequencing (FISSEQ) 15 , Multiplexed Error-robust FISH (MERFISH) 64, 67 , Sequential Barcoding FISH (seqFISH) 18, 41 , Spatially-resolved Transcript Amplicon Readout Mapping (STARmap) 17 and ClampFISH 68 are poised…”
BackgroundImmuno-SABER enables highly multiplexed and amplified protein imaging in tissues
Saka, S. K., Wang, Y., Kishi, J. Y., Zhu, A., Zeng, Y., Xie, W., Kirli, K., Yapp, C., Cicconet, M., Beliveau, B. J., et al. (2019) · Nature Biotechnology · doi:10.1038/s41587-019-0207-y · Cited by 481
SABER amplifies FISH: enhanced multiplexed imaging of RNA and DNA in cells and tissues
Kishi, J. Y., Lapan, S. W., Beliveau, B. J., West, E. R., Zhu, A., Sasaki, H. M., Saka, S. K., Wang, Y., Cepko, C. L., & Yin, P. (2019) · Nature Methods · doi:10.1038/s41592-019-0404-0 · Cited by 454
Metadata
- Authors
- Rouhanifard, S. H., Mellis, I. A., Dunagin, M., Bayatpour, S., Jiang, C. L., Dardani, I., Symmons, O., Emert, B., Torre, E., Cote, A., Sullivan, A., Stamatoyannopoulos, J. A., & Raj, A.
- Venue
- Nature Biotechnology
- Published
- 2018-11-12
- Volume
- 37
- Issue
- 1
- Pages
- 84-89
- ISSN
- 0733-222X (ISSN-L)
- 1087-0156
- 1546-1696
- OpenAlex
- W2900659847
- Cited by
- 146
- References
- 2
- FWCI
- 4.87
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.