Real-time measurement of protein–protein interactions at single-molecule resolution using a biological nanopore
Open accessThe DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.
Abstract
Protein–protein interactions (PPIs) are essential for many cellular processes. However, transient PPIs are difficult to measure at high throughput or in complex biological fluids using existing methods. We engineered a genetically encoded sensor for real-time sampling of transient PPIs at single-molecule resolution. Our sensor comprises a truncated outer membrane protein pore, a flexible tether, a protein receptor and a peptide adaptor. When a protein ligand present in solution binds to the receptor, reversible capture and release events of the receptor can be measured as current transitions between two open substates of the pore. Notably, the binding and release of the receptor by a protein ligand can be unambiguously discriminated in a complex sample containing fetal bovine serum. Our selective nanopore sensor could be applied for single-molecule protein detection, could form the basis for a nanoproteomics platform or might be adapted to build tools for protein profiling and biomarker discovery.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(1995) · Springer eBooks · doi:10.1007/978-1-4419-1229-9 · Cited by 2,526
Three decades of nanopore sequencing
Deamer, D., Akeson, M., & Branton, D. (2016) · Nature Biotechnology · doi:10.1038/nbt.3423 · Cited by 1,292
Isothermal Titration Calorimetry of Protein–Protein Interactions
Pierce, M. M., Raman, C. S., & Nall, B. T. (1999) · Methods · doi:10.1006/meth.1999.0852 · Cited by 576
Schreiber, G., & Fersht, A. R. (1995) · Journal of Molecular Biology · doi:10.1016/s0022-2836(95)80064-6 · Cited by 565
Transmembrane Signaling across the Ligand-Gated FhuA Receptor
Locher, K. P., Rees, B., Koebnik, R., Mitschler, A., Moulinier, L., Rosenbusch, J. P., & Moras, D. (1998) · Cell · doi:10.1016/s0092-8674(00)81700-6 · Cited by 540
Transient Protein-Protein Interactions: Structural, Functional, and Network Properties
Perkins, J. R., Diboun, I., Dessailly, B. H., Lees, J. G., & Orengo, C. (2010) · Structure · doi:10.1016/j.str.2010.08.007 · Cited by 520
Stochastic sensing of proteins with receptor-modified solid-state nanopores
Wei, R., Gatterdam, V., Wieneke, R., Tampé, R., & Rant, U. (2012) · Nature Nanotechnology · doi:10.1038/nnano.2012.24 · Cited by 487
Paving the way to single-molecule protein sequencing
Restrepo-Pérez, L., Joo, C., & Dekker, C. (2018) · Nature Nanotechnology · doi:10.1038/s41565-018-0236-6 · Cited by 396
Burns, J. R., Seifert, A., Fertig, N., & Howorka, S. (2016) · Nature Nanotechnology · doi:10.1038/nnano.2015.279 · Cited by 374
Movileanu, L., Howorka, S., Braha, O., & Bayley, H. (2000) · Nature Biotechnology · doi:10.1038/80295 · Cited by 366
Self-citationBuckle, A. M., Schreiber, G., & Fersht, A. R. (1994) · Biochemistry · doi:10.1021/bi00196a004 · Cited by 359
Stochastic Sensing of Proteins with Receptor-Modified Solid-State Nanopores
Wei, R., Tampé, R., & Rant, U. (2012) · Biophysical Journal · doi:10.1016/j.bpj.2011.11.2351 · Cited by 354
Protein Detection by Nanopores Equipped with Aptamers
Rotem, D., Jayasinghe, L., Salichou, M., & Bayley, H. (2012) · Journal of the American Chemical Society · doi:10.1021/ja2105653 · Cited by 312
Howorka, S. (2017) · Nature Nanotechnology · doi:10.1038/nnano.2017.99 · Cited by 293
Interaction of barnase with its polypeptide inhibitor barstar studied by protein engineering
Schreiber, G., & Fersht, A. R. (1993) · Biochemistry · doi:10.1021/bi00070a025 · Cited by 280
Huang, G., Willems, K., Soskine, M., Wloka, C., & Maglia, G. (2017) · Nature Communications · doi:10.1038/s41467-017-01006-4 · Cited by 278
Disease Detection and Management via Single Nanopore-Based Sensors
Reiner, J. E., Balijepalli, A., Robertson, J. W. F., Campbell, J., Suehle, J., & Kasianowicz, J. J. (2012) · Chemical Reviews · doi:10.1021/cr300381m · Cited by 245
McManus, O. B., & Magleby, K. L. (1988) · The Journal of Physiology · doi:10.1113/jphysiol.1988.sp017195 · Cited by 231
Sze, J. Y. Y., Ivanov, A. P., Cass, A. E. G., & Edel, J. B. (2017) · Nature Communications · doi:10.1038/s41467-017-01584-3 · Cited by 222
Kennedy, E., Dong, Z., Tennant, C., & Timp, G. (2016) · Nature Nanotechnology · doi:10.1038/nnano.2016.120 · Cited by 193
Design of multivalent complexes using the barnase·barstar module
Deyev, S. M., Waibel, R., Lebedenko, E. N., Schubiger, A. P., & Plückthun, A. (2003) · Nature Biotechnology · doi:10.1038/nbt916 · Cited by 191
Protein–Protein Interactions: Surface Plasmon Resonance
(2017) · doi:10.1007/978-1-4939-7033-9_21 · Cited by 159
Engineering a Rigid Protein Tunnel for Biomolecular Detection
Mohammad, M. M., Iyer, R., Howard, K. R., McPike, M. P., Borer, P. N., & Movileanu, L. (2012) · Journal of the American Chemical Society · doi:10.1021/ja3043646 · Cited by 129
Self-citationDiscrimination among Protein Variants Using an Unfoldase-Coupled Nanopore
Nivala, J., Mulroney, L., Li, G., Schreiber, J., & Akeson, M. (2014) · ACS Nano · doi:10.1021/nn5049987 · Cited by 128
Engineered transmembrane pores
Ayub, M., & Bayley, H. (2016) · Current Opinion in Chemical Biology · doi:10.1016/j.cbpa.2016.08.005 · Cited by 115
Redesign of a Plugged β-Barrel Membrane Protein
Mohammad, M. M., Howard, K. R., & Movileanu, L. (2010) · Journal of Biological Chemistry · doi:10.1074/jbc.m110.197723 · Cited by 75
Self-citationHarrington, L., Cheley, S., Alexander, L. T., Knapp, S., & Bayley, H. (2013) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1312739110 · Cited by 57
Studying protein–protein interactions: progress, pitfalls and solutions
Hayes, S. L., Malacrida, B., Bailey‐Whyte, M., & Kiely, P. A. (2016) · Biochemical Society Transactions · doi:10.1042/bst20160092 · Cited by 51
Yoo, J., Lee, T.-S., Choi, B., Shon, M. J., & Yoon, T. (2016) · Journal of the American Chemical Society · doi:10.1021/jacs.6b09542 · Cited by 25
Mapping Transient Protein Interactions at the Nanoscale in Living Mammalian Cells
Keersmaecker, H. D., Camacho, R., Rantasa, D. M., Fron, E., Uji‐i, H., Mizuno, H., & Rocha, S. (2018) · ACS Nano · doi:10.1021/acsnano.8b01227 · Cited by 24
Gonzalez, L. C. (2012) · Methods · doi:10.1016/j.ymeth.2012.06.004 · Cited by 24
Aberrantly Large Single-Channel Conductance of Polyhistidine Arm-Containing Protein Nanopores
Thakur, A. K., Larimi, M. G., Gooden, K., & Movileanu, L. (2017) · Biochemistry · doi:10.1021/acs.biochem.7b00577 · Cited by 19
Self-citationAntibiotic translocation through porins studied in planar lipid bilayers using parallel platforms
Weichbrodt, C., Bajaj, H., Baaken, G., Wang, J., Guinot, S., Kreir, M., Behrends, J. C., Winterhalter, M., & Fertig, N. (2015) · The Analyst · doi:10.1039/c4an02335h · Cited by 16
Nogal, B., Bowman, C. A., & Ward, A. B. (2017) · Journal of Biological Chemistry · doi:10.1074/jbc.m117.808352 · Cited by 13
Cited by
Nanopore-based technologies beyond DNA sequencing
Ying, Y.-L., Hu, Z.-L., Zhang, S., Qing, Y., Fragasso, A., Maglia, G., Meller, A., Bayley, H., Dekker, C., & Long, Y.-T. (2022) · Nature Nanotechnology · doi:10.1038/s41565-022-01193-2 · Cited by 538
Single-molecule evidence of Entropic Pulling by Hsp70 chaperones
Rukes, V., Rebeaud, M. E., Perrin, L. W., De Los Rios, P., & Cao, C. (2024) · Nature Communications · doi:10.1038/s41467-024-52674-y · Cited by 24
Metadata
- Authors
- Thakur, A. K., & Movileanu, L.
- Venue
- Nature Biotechnology
- Published
- 2018-12-10
- Volume
- 37
- Issue
- 1
- Pages
- 96-101
- ISSN
- 0733-222X (ISSN-L)
- 1087-0156
- 1546-1696
- OpenAlex
- W2904588797
- Cited by
- 205
- References
- 34
- FWCI
- 6.23
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.