The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Ultra-sensitive optical oxygen sensors for characterization of nearly anoxic systems
Open accessAbstract
Oxygen quantification in trace amounts is essential in many fields of science and technology. Optical oxygen sensors proved invaluable tools for oxygen measurements in a broad concentration range, but until now neither optical nor electrochemical oxygen sensors were able to quantify oxygen in the sub-nanomolar concentration range. Herein we present new optical oxygen-sensing materials with unmatched sensitivity. They rely on the combination of ultra-long decaying (several 100 ms lifetime) phosphorescent boron- and aluminium-chelates, and highly oxygen-permeable and chemically stable perfluorinated polymers. The sensitivity of the new sensors is improved up to 20-fold compared with state-of-the-art analogues. The limits of detection are as low as 5 p.p.b., volume in gas phase under atmospheric pressure or 7 pM in solution. The sensors enable completely new applications for monitoring of oxygen in previously inaccessible concentration ranges. Accurately detecting low concentrations of oxygen is important in many fields, but current detection systems have limited sensitivity. Here, the authors report sensor materials based on phosphorescent boron or aluminium complexes in perfluorinated polymers, capable of detecting oxygen down to picomolar levels.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
BODIPY Dyes and Their Derivatives: Syntheses and Spectroscopic Properties
Loudet, A., & Burgess, K. (2007) · Chemical Reviews · doi:10.1021/cr078381n · Cited by 5,238
Cited by
Kwon, M. S., Yu, Y., Coburn, C., Phillips, A. W., Chung, K., Shanker, A., Jung, J., Kim, G., Pipe, K., Forrest, S. R., et al. (2015) · Nature Communications · doi:10.1038/ncomms9947 · Cited by 451
Chen, X., Xu, C., Wang, T., Zhou, C., Du, J., Wang, Z., Xu, H., Xie, T., Bi, G., Jiang, J., et al. (2016) · Angewandte Chemie International Edition · doi:10.1002/anie.201601252 · Cited by 445
Yang, Z., Xu, C., Li, W., Mao, Z., Ge, X., Huang, Q., Deng, H., Zhao, J., Gu, F. L., Zhang, Y., et al. (2020) · Angewandte Chemie International Edition · doi:10.1002/anie.202007343 · Cited by 386
de Souza, B., Farias, G., Neese, F., & Izsák, R. (2019) · Journal of Chemical Theory and Computation · doi:10.1021/acs.jctc.8b00841 · Cited by 323
Hamzehpoor, E., Ruchlin, C., Tao, Y., Liu, C.-H., Titi, H. M., & Perepichka, D. F. (2023) · Nature Chemistry · doi:10.1038/s41557-022-01070-4 · Cited by 257
Metadata
- Authors
- Lehner, P., Staudinger, C., Borisov, S. M., & Klimant, I.
- Venue
- Nature Communications
- Published
- 2014-07-21
- Volume
- 5
- Issue
- 1
- Pages
- 4460-4460
- ISSN
- 2041-1723 (ISSN-L)
- OpenAlex
- W1984138304
- Cited by
- 188
- References
- 1
- FWCI
- 10.67
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.