An atomic model of brome mosaic virus using direct electron detection and real-space optimization
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Advances in electron cryo-microscopy have enabled structure determination of macromolecules at near-atomic resolution. However, structure determination, even using de novo methods, remains susceptible to model bias and overfitting. Here we describe a complete workflow for data acquisition, image processing, all-atom modelling and validation of brome mosaic virus, an RNA virus. Data were collected with a direct electron detector in integrating mode and an exposure beyond the traditional radiation damage limit. The final density map has a resolution of 3.8 Å as assessed by two independent data sets and maps. We used the map to derive an all-atom model with a newly implemented real-space optimization protocol. The validity of the model was verified by its match with the density map and a previous model from X-ray crystallography, as well as the internal consistency of models from independent maps. This study demonstrates a practical approach to obtain a rigorously validated atomic resolution electron cryo-microscopy structure. Recent developments in cryo-electron microscopy have enabled structure determination of large protein complexes at almost atomic resolution. Wang et al.combine some of these technologies into an effective workflow, and demonstrate the protocol by solving the atomic structure of an icosahedral RNA virus.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Towards automated crystallographic structure refinement with phenix.refine
Afonine, P. V., Grosse-Kunstleve, R. W., Echols, N., Headd, J. J., Moriarty, N. W., Mustyakimov, M., Terwilliger, T. C., Urzhumtsev, A., Zwart, P. H., & Adams, P. D. (2012) · Acta Crystallographica Section D Biological Crystallography · doi:10.1107/s0907444912001308 · Cited by 5,511 · cited 2×
“Traditionally, Phenix and other crystallographic packages perform model optimization in reciprocal-space, improving the model with respect to X-ray crystallographic data, and thus generating updated phase information for electron density calculations 38 .”
Self-citationRosenthal, P. B., & Henderson, R. (2003) · Journal of Molecular Biology · doi:10.1016/j.jmb.2003.07.013 · Cited by 2,416
Outcome of the first electron microscopy validation task force meeting
Henderson, R., Sali, A., Baker, M. L., Carragher, B., Devkota, B., Downing, K. H., Egelman, E. H., Feng, Z., Frank, J., Grigorieff, N., et al. (2012) · Structure · doi:10.1016/j.str.2011.12.014 · Cited by 505
Self-citation
Cited by
MotionCor2: anisotropic correction of beam-induced motion for improved cryo-electron microscopy
Zheng, S. Q., Palovcak, E., Armache, J.-P., Verba, K. A., Cheng, Y., & Agard, D. A. (2017) · Nature Methods · doi:10.1038/nmeth.4193 · Cited by 7,777
EMRinger: side chain–directed model and map validation for 3D cryo-electron microscopy
Barad, B. A., Echols, N., Wang, R. Y.-R., Cheng, Y., DiMaio, F., Adams, P. D., & Fraser, J. S. (2015) · Nature Methods · doi:10.1038/nmeth.3541 · Cited by 886
Self-citationDeterministic photon–emitter coupling in chiral photonic circuits
Söllner, I., Mahmoodian, S., Hansen, S. L., Midolo, L., Javadi, A., Kiršanskė, G., Pregnolato, T., El-Ella, H., Lee, E. H., Song, J. D., et al. (2015) · Nature Nanotechnology · doi:10.1038/nnano.2015.159 · Cited by 654
Designer nanoscale DNA assemblies programmed from the top down
Veneziano, R., Ratanalert, S., Zhang, K., Zhang, F., Yan, H., Chiu, W., & Bathe, M. (2016) · Science · doi:10.1126/science.aaf4388 · Cited by 620
Self-citationMolecular Structure of the Human CFTR Ion Channel
Liu, F., Zhang, Z., Csanády, L., Gadsby, D. C., & Chen, J. (2017) · Cell · doi:10.1016/j.cell.2017.02.024 · Cited by 523
Metadata
- Authors
- Wang, Z., Hryc, C. F., Bammes, B., Afonine, P. V., Jakana, J., Chen, D.-H., Liu, X., Baker, M. L., Kao, C., Ludtke, S. J., Schmid, M. F., Adams, P. D., & Chiu, W.
- Venue
- Nature Communications
- Published
- 2014-09-04
- Volume
- 5
- Issue
- 1
- Pages
- 4808-4808
- ISSN
- 2041-1723 (ISSN-L)
- OpenAlex
- W2067374400
- Cited by
- 120
- References
- 3
- FWCI
- 12.23
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.