The DOI matches its Crossref record.
Paramagnetic fluorinated nanoemulsions for sensitive cellular fluorine-19 magnetic resonance imaging
Open accessAbstract
Fluorine-19 magnetic resonance imaging (19F MRI) probes enable quantitative in vivo detection of cell therapies and inflammatory cells. Here, we describe the formulation of perfluorocarbon-based nanoemulsions with improved sensitivity for cellular MRI. Reduction of the 19F spin-lattice relaxation time (T1) enables rapid imaging and an improved signal-to-noise ratio, thereby improving cell detection sensitivity. We synthesized metal-binding β-diketones conjugated to linear perfluoropolyether (PFPE), formulated these fluorinated ligands as aqueous nanoemulsions, and then metalated them with various transition and lanthanide ions in the fluorous phase. Iron(III) tris-β-diketonate ('FETRIS') nanoemulsions with PFPE have low cytotoxicity (<20%) and superior MRI properties. Moreover, the 19F T1 can readily be reduced by an order of magnitude and tuned by stoichiometric modulation of the iron concentration. The resulting 19F MRI detection sensitivity is enhanced by 3-to-5 fold over previously used tracers at 11.7 T, and is predicted to increase by at least 8-fold at clinical field strength of 3 T.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Nanoemulsion: Concepts, development and applications in drug delivery
Singh, Y., Meher, J. G., Raval, K., Khan, F. A., Chaurasia, M., Jain, N. K., & Chourasia, M. K. (2017) · Journal of Controlled Release · doi:10.1016/j.jconrel.2017.03.008 · Cited by 1,358
Zhang, C., Yan, K., Fu, C., Peng, H., Hawker, C. J., & Whittaker, A. K. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00632 · Cited by 493
Fluoropolymers in Biomedical Applications: State-of-the-Art and Future Perspectives
Lv, J., & Cheng, Y. (2021) · Chemical Society Reviews · doi:10.1039/d0cs00258e · Cited by 316
Shen, Z., Chen, T., Ma, X., Ren, W., Zhou, Z., Zhu, G., Zhang, A., Liu, Y., Song, J., Li, Z., et al. (2017) · ACS Nano · doi:10.1021/acsnano.7b04924 · Cited by 298
Litti, L., Rivato, N., Fracasso, G., Bontempi, P., Nicolato, E., Marzola, P., Venzo, A., Colombatti, M., Gobbo, M., & Meneghetti, M. (2018) · Nanoscale · doi:10.1039/c7nr07398d · Cited by 33
Metadata
- Authors
- Kislukhin, A. A., Xu, H., Adams, S. R., Narsinh, K. H., Tsien, R. Y., & Ahrens, E. T.
- Venue
- Nature Materials
- Published
- 2016-03-14
- Volume
- 15
- Issue
- 6
- Pages
- 662-668
- ISSN
- 1476-1122 (ISSN-L)
- 1476-4660
- OpenAlex
- W2293288999
- Cited by
- 179
- References
- 0
- FWCI
- 8.44
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Paramagnetic fluorinated nanoemulsions for sensitive cellular fluorine-19 magnetic resonance imaging. https://app.cochat.ai/papers/10.1038/nmat4585
- The paper
- Kislukhin, A. A., Xu, H., Adams, S. R., Narsinh, K. H., Tsien, R. Y., & Ahrens, E. T. (2016). Paramagnetic fluorinated nanoemulsions for sensitive cellular fluorine-19 magnetic resonance imaging. Nature Materials. https://doi.org/10.1038/nmat4585
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.