Photoconversion in orange and red fluorescent proteins
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
We found that photoconversion is fairly common among orange and red fluorescent proteins, as in a screen of 12 proteins, 8 exhibited photoconversion. Specifically, three red fluorescent proteins could be switched to a green state, and two orange variants could be photoconverted to a far-red state. The orange proteins are ideal for dual-probe highlighter applications, and they exhibited the most red-shifted excitation of all fluorescent proteins described to date.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Shaner, N. C., Campbell, R. E., Steinbach, P. A., Giepmans, B. N. G., Palmer, A. E., & Tsien, R. Y. (2004) · Nature Biotechnology · doi:10.1038/nbt1037 · Cited by 4,619
Engineering of a monomeric green-to-red photoactivatable fluorescent protein induced by blue light
Gurskaya, N. G., Verkhusha, V. V., Shcheglov, A. S., Staroverov, D. B., Chepurnykh, T. V., Fradkov, A. F., Lukyanov, S., & Lukyanov, K. A. (2006) · Nature Biotechnology · doi:10.1038/nbt1191 · Cited by 725
Cited by
Fluorescent Proteins and Their Applications in Imaging Living Cells and Tissues
Chudakov, D. M., Matz, M. V., Lukyanov, S., & Lukyanov, K. A. (2010) · Physiological Reviews · doi:10.1152/physrev.00038.2009 · Cited by 1,375
Sensitive red protein calcium indicators for imaging neural activity
Dana, H., Mohar, B., Sun, Y., Narayan, S., Gordus, A., Hasseman, J. P., Tsegaye, G., Holt, G. T., Hu, A., Walpita, D., et al. (2016) · eLife · doi:10.7554/elife.12727 · Cited by 1,034
The fluorescent protein palette: tools for cellular imaging
Day, R. N., & Davidson, M. W. (2009) · Chemical Society Reviews · doi:10.1039/b901966a · Cited by 810
Self-citationImproving FRET dynamic range with bright green and red fluorescent proteins
Lam, A. J., St-Pierre, F., Gong, Y., Marshall, J. D., Cranfill, P. J., Baird, M. A., McKeown, M. R., Wiedenmann, J., Davidson, M. W., Schnitzer, M. J., et al. (2012) · Nature Methods · doi:10.1038/nmeth.2171 · Cited by 732
“OFPs exhibit poor maturation, rapid photobleaching, and/or photoconversion to green or far-red species, all of which can lead to underestimations of FRET 2,16,18 .”
Self-citationAdvanced Fluorescence Microscopy Techniques—FRAP, FLIP, FLAP, FRET and FLIM
Ishikawa-Ankerhold, H. C., Ankerhold, R., & Drummen, G. P. C. (2012) · Molecules · doi:10.3390/molecules17044047 · Cited by 557
Metadata
- Authors
- Kremers, G.-J., Hazelwood, K. L., Murphy, C. S., Davidson, M. W., & Piston, D. W.
- Venue
- Nature Methods
- Published
- 2009-04-12
- Volume
- 6
- Issue
- 5
- Pages
- 355-358
- ISSN
- 1548-7091 (ISSN-L)
- 1548-7105
- OpenAlex
- W1991854860
- Cited by
- 130
- References
- 2
- FWCI
- 7.87
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.