The DOI matches its Crossref record.
Ultrahigh-resolution optical trap with single-fluorophore sensitivity
Open accessAbstract
We present a single-molecule instrument that combines a time-shared ultrahigh-resolution dual optical trap interlaced with a confocal fluorescence microscope. In a demonstration experiment, we observed individual single fluorophore–labeled DNA oligonucleotides to bind and unbind complementary DNA suspended between two trapped beads. Simultaneous with the single-fluorophore detection, we clearly observed coincident angstrom-scale changes in tether extension. Fluorescence readout allowed us to determine the duplex melting rate as a function of force. The new instrument will enable the simultaneous measurement of angstrom-scale mechanical motion of individual DNA-binding proteins (for example, single-base-pair stepping of DNA translocases) along with the detection of properties of fluorescently labeled protein (for example, internal configuration).
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Optical tweezers in single-molecule biophysics
Bustamante, C. J., Chemla, Y. R., Liu, S., & Wang, M. D. (2021) · Nature Reviews Methods Primers · doi:10.1038/s43586-021-00021-6 · Cited by 615
Self-citationOptical tweezers study life under tension
Fazal, F. M., & Block, S. M. (2011) · Nature Photonics · doi:10.1038/nphoton.2011.100 · Cited by 396
Population-based heteropolymer design to mimic protein mixtures
Ruan, Z., Li, S., Grigoropoulos, A., Amiri, H., Hilburg, S. L., Chen, H., Jayapurna, I., Jiang, T., Gu, Z., Alexander-Katz, A., et al. (2023) · Nature · doi:10.1038/s41586-022-05675-0 · Cited by 64
Metadata
- Authors
- Comstock, M. J., Ha, T., & Chemla, Y. R.
- Venue
- Nature Methods
- Published
- 2011-02-20
- Volume
- 8
- Issue
- 4
- Pages
- 335-340
- ISSN
- 1548-7091 (ISSN-L)
- 1548-7105
- OpenAlex
- W2160445124
- Cited by
- 189
- References
- 0
- FWCI
- 10.59
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.