The DOI matches its Crossref record.
Subnanometre resolution in three-dimensional magnetic resonance imaging of individual dark spins
Open accessAbstract
Magnetic resonance imaging (MRI) has revolutionized biomedical science by providing non-invasive, three-dimensional biological imaging. However, spatial resolution in conventional MRI systems is limited to tens of micrometres, which is insufficient for imaging on molecular scales. Here, we demonstrate an MRI technique that provides subnanometre spatial resolution in three dimensions, with single electron-spin sensitivity. Our imaging method works under ambient conditions and can measure ubiquitous 'dark' spins, which constitute nearly all spin targets of interest. In this technique, the magnetic quantum-projection noise of dark spins is measured using a single nitrogen-vacancy (NV) magnetometer located near the surface of a diamond chip. The distribution of spins surrounding the NV magnetometer is imaged with a scanning magnetic-field gradient. To evaluate the performance of the NV-MRI technique, we image the three-dimensional landscape of electronic spins at the diamond surface and achieve an unprecedented combination of resolution (0.8 nm laterally and 1.5 nm vertically) and single-spin sensitivity. Our measurements uncover electronic spins on the diamond surface that can potentially be used as resources for improved magnetic imaging. This NV-MRI technique is immediately applicable to diverse systems including imaging spin chains, readout of spin-based quantum bits, and determining the location of spin labels in biological systems.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Sensitivity optimization for NV-diamond magnetometry
Barry, J. F., Schloss, J. M., Bauch, E., Turner, M. J., Hart, C. A., Pham, L. M., & Walsworth, R. L. (2020) · Reviews of Modern Physics · doi:10.1103/revmodphys.92.015004 · Cited by 1,247
Self-citationSingle-protein spin resonance spectroscopy under ambient conditions
Shi, F., Zhang, Q., Wang, P., Sun, H., Wang, J., Rong, X., Chen, M., Ju, C., Reinhard, F., Chen, H., et al. (2015) · Science · doi:10.1126/science.aaa2253 · Cited by 406
Nanoscale NMR spectroscopy and imaging of multiple nuclear species
DeVience, S. J., Pham, L. M., Lovchinsky, I., Sushkov, A. O., Bar-Gill, N., Belthangady, C., Casola, F., Corbett, M., Zhang, H., Lukin, M., et al. (2015) · Nature Nanotechnology · doi:10.1038/nnano.2014.313 · Cited by 276
Self-citationSpectroscopy of Surface-Induced Noise Using Shallow Spins in Diamond
Romach, Y., Müller, C., Unden, T., Rogers, L. J., Isoda, T., Itoh, K. M., Markham, M., Stacey, A., Meijer, J., Pezzagna, S., et al. (2015) · Physical Review Letters · doi:10.1103/physrevlett.114.017601 · Cited by 259
Experimental fault-tolerant universal quantum gates with solid-state spins under ambient conditions
Rong, X., Geng, J., Shi, F., Liu, Y., Xu, K., Ma, W., Kong, F., Jiang, Z., Wu, Y., & Du, J. (2015) · Nature Communications · doi:10.1038/ncomms9748 · Cited by 257
Metadata
- Authors
- Grinolds, M. S., Warner, M., De Greve, K., Dovzhenko, Y., Thiel, L., Walsworth, R. L., Hong, S., Maletinsky, P., & Yacoby, A.
- Venue
- Nature Nanotechnology
- Published
- 2014-03-23
- Volume
- 9
- Issue
- 4
- Pages
- 279-284
- ISSN
- 1748-3387 (ISSN-L)
- 1748-3395
- OpenAlex
- W2158118753
- Cited by
- 273
- References
- 0
- FWCI
- 14.29
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Subnanometre resolution in three-dimensional magnetic resonance imaging of individual dark spins. https://app.cochat.ai/papers/10.1038/nnano.2014.30
- The paper
- Grinolds, M. S., Warner, M., De Greve, K., Dovzhenko, Y., Thiel, L., Walsworth, R. L., Hong, S., Maletinsky, P., & Yacoby, A. (2014). Subnanometre resolution in three-dimensional magnetic resonance imaging of individual dark spins. Nature Nanotechnology. https://doi.org/10.1038/nnano.2014.30
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.