Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 348

The DOI matches its Crossref record; 43 of the 43 references it cites were found in a registry or an index.

Acoustic terahertz graphene plasmons revealed by photocurrent nanoscopy

Open access
Alonso-González, Pablo, Nikitin, Alexey Y., Gao, Yuanda, Woessner, Achim, Lundeberg, Mark B., Principi, Alessandro, Forcellini, Nicolò, Yan, Wenjing, Vélez, Saül, Huber, Andreas. J., Watanabe, Kenji, Taniguchi, Takashi, Casanova, Félix, Hueso, Luis E., Polini, Marco, Hone, James, Koppens, Frank H. L., Hillenbrand, Rainer·2017·Nature Nanotechnology

Abstract

Terahertz (THz) fields are widely used for sensing, communication and quality control. In future applications, they could be efficiently confined, enhanced and manipulated well below the classical diffraction limit through the excitation of graphene plasmons (GPs). These possibilities emerge from the strongly reduced GP wavelength, λp, compared with the photon wavelength, λ0, which can be controlled by modulating the carrier density of graphene via electrical gating. Recently, GPs in a graphene/insulator/metal configuration have been predicted to exhibit a linear dispersion (thus called acoustic plasmons) and a further reduced wavelength, implying an improved field confinement, analogous to plasmons in two-dimensional electron gases (2DEGs) near conductive substrates. Although infrared GPs have been visualized by scattering-type scanning near-field optical microscopy (s-SNOM), the real-space imaging of strongly confined THz plasmons in graphene and 2DEGs has been elusive so far-only GPs with nearly free-space wavelengths have been observed. Here we demonstrate real-space imaging of acoustic THz plasmons in a graphene photodetector with split-gate architecture. To that end, we introduce nanoscale-resolved THz photocurrent near-field microscopy, where near-field excited GPs are detected thermoelectrically rather than optically. This on-chip detection simplifies GP imaging as sophisticated s-SNOM detection schemes can be avoided. The photocurrent images reveal strongly reduced GP wavelengths (λp ≈ λ0/66), a linear dispersion resulting from the coupling of GPs with the metal gate below the graphene, and that plasmon damping at positive carrier densities is dominated by Coulomb impurity scattering.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1038/nnano.2016.185

Cites

43 of 43 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 43 references

Cited by

See all 348

Metadata

Authors
Alonso-González, P., Nikitin, A. Y., Gao, Y., Woessner, A., Lundeberg, M. B., Principi, A., Forcellini, N., Yan, W., Vélez, S., Huber, A. J., Watanabe, K., Taniguchi, T., Casanova, F., Hueso, L. E., Polini, M., Hone, J., Koppens, F. H. L., & Hillenbrand, R.
Venue
Nature Nanotechnology
Published
2016-10-24
Volume
12
Issue
1
Pages
31-35
ISSN
  • 1748-3387 (ISSN-L)
  • 1748-3395
OpenAlex
W2300471825
Cited by
348
References
43
FWCI
15.50
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Acoustic terahertz graphene plasmons revealed by photocurrent nanoscopy. https://app.cochat.ai/papers/10.1038/nnano.2016.185
The paper
Alonso-González, P., Nikitin, A. Y., Gao, Y., Woessner, A., Lundeberg, M. B., Principi, A., Forcellini, N., Yan, W., Vélez, S., Huber, A. J., Watanabe, K., Taniguchi, T., Casanova, F., Hueso, L. E., Polini, M., Hone, J., Koppens, F. H. L., & Hillenbrand, R. (2017). Acoustic terahertz graphene plasmons revealed by photocurrent nanoscopy. Nature Nanotechnology. https://doi.org/10.1038/nnano.2016.185

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.