Biomolecular imaging and electronic damage using X-ray free-electron lasers
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
A potentially critical limiting factor in the use of free-electron lasers to determine the structure of organic molecules is the damage the procedure may cause. A model based on coherence theory and quantum electrodynamics suggests that it should be possible to reconstruct a molecule’s structure from the X-ray data obtained as it undergoes damage.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Potential for biomolecular imaging with femtosecond X-ray pulses
Neutze, R., Wouts, R., van der Spoel, D., Weckert, E., & Hajdu, J. (2000) · Nature · doi:10.1038/35021099 · Cited by 2,022 · cited 1×
“dtd" [ ]> The challenges involved in determining the structures of molecules to atomic resolution in non-crystalline samples using X-ray free-electron laser pulses are formidabl”
Femtosecond electronic response of atoms to ultra-intense X-rays
Young, L., Kanter, E. P., Krässig, B., Li, Y., March, A. M., Pratt, S. T., Santra, R., Southworth, S. H., Rohringer, N., DiMauro, L. F., et al. (2010) · Nature · doi:10.1038/nature09177 · Cited by 792 · cited 1×
“This feature may facilitate the incorporation of recently reported experimental information on the femtosecond electronic response of atoms as part of an integrated imaging strateg”
Background
Cited by
X-Rays and Extreme Ultraviolet Radiation: Principles and Applications
Attwood, D., & Sakdinawat, A. (2016) · CERN Document Server (European Organization for Nuclear Research) · doi:10.1017/cbo9781107477629 · Cited by 644
Self-terminating diffraction gates femtosecond X-ray nanocrystallography measurements
Barty, A., Caleman, C., Aquila, A., Timneanu, N., Lomb, L., White, T. A., Andreasson, J., Arnlund, D., Bajt, S., Barends, T. R. M., et al. (2012) · Nature Photonics · doi:10.1038/nphoton.2011.297 · Cited by 344
Short-wavelength free-electron laser sources and science: a review
Seddon, E. A., Clarke, J. A., Dunning, D. J., Masciovecchio, C., Milne, C. J., Parmigiani, F., Rugg, D., Spence, J. C. H., Thompson, N. R., Ueda, K., et al. (2017) · Reports on Progress in Physics · doi:10.1088/1361-6633/aa7cca · Cited by 252
High-resolution three-dimensional partially coherent diffraction imaging
Clark, J. N., Huang, X., Harder, R., & Robinson, I. K. (2012) · Nature Communications · doi:10.1038/ncomms1994 · Cited by 232
X-ray lasers for structural and dynamic biology
Spence, J. C. H., Weierstall, U., & Chapman, H. N. (2012) · Reports on Progress in Physics · doi:10.1088/0034-4885/75/10/102601 · Cited by 213
“An approach which estimates the effect of electronic damage on loss of coherence in the scattered radiation (because the electronic structure is in motion) has been given by Quiney and Nugent (2011), which allows correction of this effect and the extraction of additional sample information.”
Background
Metadata
- Authors
- Quiney, H. M., & Nugent, K. A.
- Venue
- Nature Physics
- Published
- 2010-12-19
- Volume
- 7
- Issue
- 2
- Pages
- 142-146
- ISSN
- 1745-2473 (ISSN-L)
- 1745-2481
- OpenAlex
- W2076596341
- Cited by
- 122
- References
- 2
- FWCI
- 11.37
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.