Test of relativistic time dilation with fast optical atomic clocks at different velocities
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Ives-Stillwell type experiments using heavy-ion storage rings now give the best constraint on alpha.
“With the advent of heavy-ion storage rings, Ives-Stillwell type experiments now give the best constraint on α [16,17].”
From Test of Special Relativity Using a Fiber Network of Optical Clocks (2017) · cites this paper as [16]
A limit of |alpha| <= 8.4 x 10^-8 was found using 7Li+ ions prepared in a storage ring to 6.4% and 3.0% of the speed of light.
“A limit of jαj ≤ 8.4 × 10 -8 was found using 7 Li þ ions prepared in a storage ring to 6.4% and 3.0% of the speed of light [16].”
From Test of Special Relativity Using a Fiber Network of Optical Clocks (2017) · cites this paper as [16]
The citation lists haven’t been fetched yet
References 37 · Cited by 154
- Authors
- Reinhardt, S., Saathoff, G., Buhr, H., Carlson, L. A., Wolf, A., Schwalm, D., Karpuk, S., Novotny, C., Huber, G., Zimmermann, M., Holzwarth, R., Udem, T., Hänsch, T. W., & Gwinner, G.
- Affiliations
- Max Planck Society (DE)
- Johannes Gutenberg University Mainz (DE)
- Corresponding author
- Gwinner, Gerald
- ORCID
- Venue
- Nature Physics
- Published
- 2007-11-11
- Volume
- 3
- Issue
- 12
- Pages
- 861-864
- ISSN
- 1745-2473 (ISSN-L)
- 1745-2481
- OpenAlex
- W2094677972
- Cited by
- 154
- References
- 37
- Citations by year
- 2026: 5 · 2025: 5 · 2024: 14 · 2023: 4 · 2022: 5 · 2021: 2 · 2020: 9 · 2019: 7 · 2018: 4 · 2017: 8 · 2016: 7 · 2015: 10 · 2014: 12 · 2013: 8 · 2012: 8
- FWCI
- 7.14
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springer.com/tdm (tdm)
- Locations
- Nature Physics (publishedVersion)
- Max Planck Institute for Plasma Physics (submittedVersion)
- Max Planck Digital Library (submittedVersion)
- MPG.PuRe (Max Planck Society) (submittedVersion)
- Topics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Advanced Frequency and Time Standards
- Physical Sciences › Physics and Astronomy › Astronomy and Astrophysics › Relativity and Gravitational Theory
- Physical Sciences › Physics and Astronomy › Statistical and Nonlinear Physics › Noncommutative and Quantum Gravity Theories
- Keywords
- relativistic time dilation, optical atomic clocks, fast ions, ion storage ring, frequency combs, Doppler shift, Lorentz invariance, CPT violation, preferred frame, special relativity tests
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review