Evaluation of rapid diagnostic tests: malaria
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Median parasite densities for P. falciparum exceeded the minimum detection threshold documented in laboratory testing of the RDT (>100/μL) and those specified by WHO (>200/μL) in all groups.
“Poor performance observed in this study may be explained by low sensitivity to detect low density parasitaemias, although the median parasite densities for P. falciparum exceeded the minimum detection threshold documented in laboratory testing of the RDT test (>100/µL) [44] and those specified by the WHO (>200/µL) in all groups [45].”
The citation lists haven’t been fetched yet
References 40 · Cited by 170
- Authors
- Bell, D., & Peeling, R. W.
- Affiliations
- World Health Organization Regional Office for the Western Pacific (PH)
- World Bank (US)
- ORCID
- Peeling, Rosanna W.
- Venue
- Nature Reviews Microbiology
- Published
- 2006-09
- Volume
- 4
- Issue
- S9
- Pages
- S34-S38
- ISSN
- 1740-1526 (ISSN-L)
- 1740-1534
- OpenAlex
- W2044720125
- Cited by
- 170
- References
- 40
- Citations by year
- 2026: 3 · 2025: 3 · 2024: 4 · 2023: 5 · 2022: 4 · 2021: 6 · 2020: 4 · 2019: 6 · 2018: 5 · 2017: 11 · 2016: 3 · 2015: 13 · 2014: 15 · 2013: 18 · 2012: 19
- FWCI
- 1.42
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springer.com/tdm (tdm)
- Locations
- Nature Reviews Microbiology (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Malaria Research and Control
- Physical Sciences › Engineering › Biomedical Engineering › Biosensors and Analytical Detection
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Clinical Biochemistry › Bacterial Identification and Susceptibility Testing
- Keywords
- rapid diagnostic tests, malaria, malaria diagnosis, diagnostic test evaluation, Plasmodium falciparum
- MeSH terms
- Antigens, Protozoan, Humans, Immunologic Tests, Malaria, Microscopy, Quality Control, Reagent Kits, Diagnostic, Polymerase Chain Reaction
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review