A New Hand‐Held Indirect Calorimeter to Measure Postprandial Energy Expenditure
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Objective: To verify the accuracy of a new hand‐held metabolic rate measuring device (MedGem) in quantifying postprandial energy expenditure (PP EE). MedGem measurements were compared to measurements obtained with a conventional indirect calorimeter (Delta‐Trac). Research Methods and Procedures: The resting metabolic rate of 15 healthy subjects was measured for 20 minutes using Delta‐Trac followed by a 10‐minute measurement period using MedGem. EE was again measured for 7 hours after consumption of a 2510‐kJ breakfast. Measurements were read from the Delta‐Trac for the initial 50 minutes of each hour followed by a single reading from the MedGem after 5 to 10 minutes of measurement. Measured EE was calculated as the average of the total measurement period for Delta‐Trac and for eight readings using MedGem; PP EE was calculated as the average of all measurements obtained after breakfast consumption. Results: There was no difference in resting metabolic rate between the two methods (6455.1 ± 417.6 vs. 6468.5 ± 337.2 kJ/d for Delta‐Trac and MedGem, respectively). Measured EE and PP EE values with Delta‐Trac (7019.1 ± 400.8 and 7099.8 ± 399.2 kJ/d, respectively) and MedGem (6775.6 ± 372.0 and 6819.5 ± 379.9 kJ/d, respectively) were not significantly different. There was no bias detected in any of the measurements made with MedGem compared with those of Delta‐Trac. Discussion: The new hand‐held EE measuring device can accurately track PP EE relative to a conventional indirect calorimetry system and, therefore, provides a new opportunity to assess PP EE in research settings and large‐scale trials.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Nielsen, S., Hensrud, D., Romanski, S., Levine, J., Burguera, B., & Jensen, M. (2000) · International Journal of Obesity · doi:10.1038/sj.ijo.0801317 · Cited by 93
Cited by
Assah, F. K., Ekelund, U., Brage, S., Wright, A., Mbanya, J. C., & Wareham, N. J. (2011) · International Journal of Epidemiology · doi:10.1093/ije/dyq098 · Cited by 132
The Measurement of Energy Expenditure
Branson, R. D., & Johannigman, J. A. (2004) · Nutrition in Clinical Practice · doi:10.1177/0115426504019006622 · Cited by 111
Validity and Reliability of the VO2 Master Pro for Oxygen Consumption and Ventilation Assessment
(2020) · International Journal of Exercise Science · doi:10.70252/thjt1177 · Cited by 39
Metadata
- Authors
- St‐Onge, M., Rubiano, F., Jones, A., & Heymsfield, S. B.
- Venue
- Obesity Research
- Publisher
- Wiley
- Published
- 2004-04
- Volume
- 12
- Issue
- 4
- Pages
- 704-709
- ISSN
- 1071-7323 (ISSN-L)
- 1550-8528
- OpenAlex
- W2006406664
- Cited by
- 62
- References
- 1
- FWCI
- 4.18
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A New Hand‐Held Indirect Calorimeter to Measure Postprandial Energy Expenditure. https://app.cochat.ai/papers/10.1038/oby.2004.82
- The paper
- St‐Onge, M., Rubiano, F., Jones, A., & Heymsfield, S. B. (2004). A New Hand‐Held Indirect Calorimeter to Measure Postprandial Energy Expenditure. Obesity Research. https://doi.org/10.1038/oby.2004.82
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.