Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 723

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Validation and Calibration of an Accelerometer in Preschool Children

Pate, Russell R., Almeida, Maria J., McIver, Kerry L., Pfeiffer, Karin A., Dowda, Marsha·2006·Obesity

Abstract

Objective: Obesity rates in young children are increasing, and decreased physical activity is likely to be a major contributor to this trend. Studies of physical activity in young children are limited by the lack of valid and acceptable measures. The purpose of this study was to calibrate and validate the ActiGraph accelerometer for use with 3‐ to 5‐year‐old children. Research Methods and Procedures: Thirty preschool children wore an ActiGraph accelerometer (ActiGraph, Fort Walton Beach, FL) and a Cosmed portable metabolic system (Cosmed, Rome, Italy) during a period of rest and while performing three structured physical activities in a laboratory setting. Expired respiratory gases were collected, and oxygen consumption was measured on a breath‐by‐breath basis. Accelerometer data were collected at 15‐second intervals. For cross‐validation, the same children wore the same instruments while participating in unstructured indoor and outdoor activities for 20 minutes each at their preschool. Results: In calibrating the accelerometer, the correlation between V̇o2 (ml/kg per min) and counts was r = 0.82 across all activities. The only significant variable in the prediction equation was accelerometer counts (R2 = 0.90, standard error of the estimate = 4.70). In the cross‐validation, the intraclass correlation coefficient between measured and predicted V̇o2 was R = 0.57 and the Spearman correlation coefficient was R = 0.66 (p < 0.001). Cut‐off points for moderate‐ and vigorous‐intensity physical activity were identified at 420 counts/15 s (V̇o2 = 20 mL/kg per min) and 842 counts/15 s (V̇o2 = 30 mL/kg per min), respectively. When these cutpoints were applied to the cross‐validation data, percentage agreement, kappa, and modified kappa for moderate activity were 0.69, 0.36, and 0.38, respectively. For vigorous activity, the same measures were 0.81, 0.13, and 0.62. Discussion: Accelerometer counts were highly correlated with V̇o2 in young children. Accelerometers can be appropriately used as a measure of physical activity in this population.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1038/oby.2006.234

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 723

Metadata

Authors
Pate, R. R., Almeida, M. J., McIver, K. L., Pfeiffer, K. A., & Dowda, M.
Venue
Obesity
Publisher
Wiley
Published
2006-11
Volume
14
Issue
11
Pages
2000-2006
ISSN
  • 1930-7381 (ISSN-L)
  • 1930-739X
OpenAlex
W2094436282
Cited by
723
References
2
FWCI
4.31
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Validation and Calibration of an Accelerometer in Preschool Children. https://app.cochat.ai/papers/10.1038/oby.2006.234
The paper
Pate, R. R., Almeida, M. J., McIver, K. L., Pfeiffer, K. A., & Dowda, M. (2006). Validation and Calibration of an Accelerometer in Preschool Children. Obesity. https://doi.org/10.1038/oby.2006.234

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.