The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Field Validation of the MTI Actigraph and BodyMedia Armband Monitor Using the IDEEA Monitor
Abstract
Objective: Accelerometers offer considerable promise for improving estimates of physical activity (PA) and energy expenditure (EE) in free‐living subjects. Differences in calibration equations and cut‐off points have made it difficult to determine the most accurate way to process these data. The objective of this study was to compare the accuracy of various calibration equations and algorithms that are currently used with the MTI Actigraph (MTI) and the Sensewear Pro II (SP2) armband monitor. Research Methods and Procedures: College‐age participants (n = 30) wore an MTI and an SP2 while participating in normal activities of daily living. Activity patterns were simultaneously monitored with the Intelligent Device for Estimating Energy Expenditure and Activity (IDEEA) monitor to provide an accurate estimate (criterion measure) of EE and PA for this field‐based method comparison study. Results: The EE estimates from various MTI equations varied considerably, with mean differences ranging from −1.10 to 0.46 METS. The EE estimates from the two SP2 equations were within 0.10 METS of the value from the IDEEA. Estimates of time spent in PA from the MTI and SP2 ranged from 34.3 to 107.1 minutes per day, while the IDEEA yielded estimates of 52 minutes per day. Discussion: The lowest errors in estimation of time spent in PA and the highest correlations were found for the new SP2 equation and for the recently proposed MTI cut‐off point of 760 counts/min (Matthews, 2005). The study indicates that the Matthews MTI cut‐off point and the new SP2 equation provide the most accurate indicators of PA.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Calibration of the Computer Science and Applications, Inc. accelerometer
FREEDSON, P. S., MELANSON, E., & SIRARD, J. (1998) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-199805000-00021 · Cited by 3,825
Cited by
Lee, P. H., Macfarlane, D. J., Lam, T., & Stewart, S. M. (2011) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/1479-5868-8-115 · Cited by 3,370
Strath, S. J., Kaminsky, L. A., Ainsworth, B. E., Ekelund, U., Freedson, P. S., Gary, R. A., Richardson, C. R., Smith, D. T., & Swartz, A. M. (2013) · Circulation · doi:10.1161/01.cir.0000435708.67487.da · Cited by 1,029
Comparison of Self-reported versus Accelerometer-Measured Physical Activity
Dyrstad, S. M., Hansen, B. H., Holme, I. M., & Anderssen, S. A. (2014) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3182a0595f · Cited by 744
Best Practices for Using Physical Activity Monitors in Population-Based Research
MATTHEWS, C. E., HAGSTRÖMER, M., POBER, D. M., & BOWLES, H. R. (2012) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3182399e5b · Cited by 703
Practical Guide to Measuring Physical Activity
Sylvia, L. G., Bernstein, E. E., Hubbard, J. L., Keating, L., & Anderson, E. J. (2014) · Journal of the Academy of Nutrition and Dietetics · doi:10.1016/j.jand.2013.09.018 · Cited by 637
Metadata
- Authors
- Welk, G. J., McClain, J. J., Eisenmann, J. C., & Wickel, E. E.
- Venue
- Obesity
- Publisher
- Wiley
- Published
- 2007-04
- Volume
- 15
- Issue
- 4
- Pages
- 918-928
- ISSN
- 1930-7381 (ISSN-L)
- 1930-739X
- OpenAlex
- W1970496661
- Cited by
- 244
- References
- 2
- FWCI
- 6.53
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.