The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Low-dose real-time X-ray imaging with nontoxic double perovskite scintillators
Open accessAbstract
X-rays are widely used in probing inside information nondestructively, enabling broad applications in the medical radiography and electronic industries. X-ray imaging based on emerging lead halide perovskite scintillators has received extensive attention recently. However, the strong self-absorption, relatively low light yield and lead toxicity of these perovskites restrict their practical applications. Here, we report a series of nontoxic double-perovskite scintillators of Cs 2 Ag 0.6 Na 0.4 In 1-y Bi y Cl 6. By controlling the content of the heavy atom Bi 3+, the X-ray absorption coefficient, radiative emission efficiency, light yield and light decay were manipulated to maximise the scintillator performance. A light yield of up to 39,000 ± 7000 photons/MeV for Cs 2 Ag 0.6 Na 0.4 In 0.85 Bi 0.15 Cl 6 was obtained, which is much higher than that for the previously reported lead halide perovskite colloidal CsPbBr 3 (21,000 photons/MeV). The large Stokes shift between the radioluminescence (RL) and absorption spectra benefiting from self-trapped excitons (STEs) led to a negligible self-absorption effect. Given the high light output and fast light decay of this scintillator, static X-ray imaging was attained under an extremely low dose of ∼1 μGy air, and dynamic X-ray imaging of finger bending without a ghosting effect was demonstrated under a low-dose rate of 47.2 μGy air s−1. After thermal treatment at 85 °C for 50 h followed by X-ray irradiation for 50 h in ambient air, the scintillator performance in terms of the RL intensity and X-ray image quality remained almost unchanged. Our results shed light on exploring highly competitive scintillators beyond the scope of lead halide perovskites, not only for avoiding toxicity but also for better performance.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Metal Halide Perovskite Nanosheet for X-ray High-Resolution Scintillation Imaging Screens
Zhang, Y., Sun, R., Ou, X., Fu, K., Chen, Q., Ding, Y., Xu, L.-J., Liu, L., Han, Y., Malko, A. V., et al. (2019) · ACS Nano · doi:10.1021/acsnano.8b09484 · Cited by 506
Self-citationEuropium-Doped Lead-Free Cs 3 Bi 2 Br 9 Perovskite Quantum Dots and Ultrasensitive Cu 2+ Detection
Ding, N., Zhou, D., Pan, G., Xu, W., Chen, X., Li, D., Zhang, X., Zhu, J., Ji, Y., & Song, H. (2019) · ACS Sustainable Chemistry & Engineering · doi:10.1021/acssuschemeng.9b00038 · Cited by 171
Self-citation
Metadata
- Authors
- Zhu, W., Ma, W., Su, Y., Chen, Z., Chen, X., Ma, Y., Bai, L., Xiao, W., Liu, T., Zhu, H., Liu, X., Liu, H., Liu, X., & Yang, Y.
- Venue
- Light: Science & Applications
- Published
- 2020-06-30
- Volume
- 9
- Issue
- 1
- Pages
- 112-112
- ISSN
- 2047-7538 (ISSN-L)
- OpenAlex
- W3040491333
- Cited by
- 483
- References
- 2
- FWCI
- 44.40
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Low-dose real-time X-ray imaging with nontoxic double perovskite scintillators. https://app.cochat.ai/papers/10.1038/s41377-020-00353-0
- The paper
- Zhu, W., Ma, W., Su, Y., Chen, Z., Chen, X., Ma, Y., Bai, L., Xiao, W., Liu, T., Zhu, H., Liu, X., Liu, H., Liu, X., & Yang, Y. (2020). Low-dose real-time X-ray imaging with nontoxic double perovskite scintillators. Light: Science & Applications. https://doi.org/10.1038/s41377-020-00353-0
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.