Bioelectrical Impedance Vector Analysis (BIVA) for the monitoring of body composition in pregnancy

Open access
Moroni, A., Vardè, C., Giustetto, A., Stagi, S., Marini, E., Micheletti Cremasco, M.·2022·European Journal of Clinical Nutrition

Abstract

Background/objectives During pregnancy, body composition alterations can be considered as markers of complications and in this context, a non-invasive and low-cost method such as Bioelectrical Impedance Vector Analysis (BIVA), can be employed to monitor such changes. This study aimed at identifying body compartments trend during physiological pregnancy. Subjects/methods Classic and specific BIVA variables have been measured in a sample of 37 pregnant women approximately every 4 weeks of gestation and once postpartum. Researchers used both longitudinal and cross-sectional approach. The first case included data of women from the 11th to the 15th week along with data from the 28th to the 32nd week of gestation. The cross-sectional approach regarded two more specific moments (11th-12th weeks and 30th-31st weeks) and data within two months postpartum RESULTS: The longitudinal approach showed a significant decrease in classic BIVA variables (R/H, Xc/H, Z/H p < 0.001) and a shortening of the vector, pointing out that TBW and hydration increased significantly. Specific vector length increased significantly, indicating a physiological gain of FM% (p < 0.01). The cross-sectional approach showed lower values of R/H, Xc/H, Z/H between 12th-13th and 30th-31st weeks (p < 0.01), while in the postpartum period values tended to those registered at the beginning of pregnancy. No changes have been found for the phase angle in both approaches, indicating that ECW/ICW ratio remained constant CONCLUSIONS: Among physiological pregnancies, bioelectric values showed a coherent trend and these results represent a first contribution to support routine exams, leading to an early detection of anomalous values potentially correlated to pathologies.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1038/s41430-021-00990-7

Cites

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • BIA offers a non-invasive, safe, and highly reproducible method to estimate body fluid compartments and active tissue components.

    “Bioelectrical Impedance Analysis (BIA) offers a non-invasive, safe, and highly reproducible method to estimate body fluid compartments and active tissue components [17-19].”

    From Trimester-Specific Bioelectrical Impedance Reference Curves in Physiological Pregnancy: Mapping Maternal Body Composition and Hydration Trajectories (2026) · cites this paper as [17]

    The Introduction (p. 4) calls BIA fast and reliable and says it is used to estimate body liquids. The Methods (p. 7) say BIVA vectors can indicate changes in cellular mass, and the Conclusions (p. 10) describe the approach as non-invasive. The paper does not establish that it is safe or highly reproducible, and it cautions in the Introduction (p. 4) that conventional BIA cannot quantify fat-free mass during pregnancy using standard hydration assumptions. (LLM, conf=0.84)

    Experimental — accuracy not yet measured

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

The citation lists haven’t been fetched yet

References 31 · Cited by 13

Research works printed but not linked: 21

  1. [7]7. Most J, Marlatt KL, Altazan AD, Redman LM. Advances in assessing body composition during 295 pregnancy. Eur J Clin Nutr. 2018;72(5):645-56. 296
  2. [11]11. Berlit S, Stojakowits M, Tuschy B, Weiss C, Leweling H, Sütterlin M, et al. Bioelectrical impedance analysis in the assessment of pre-eclampsia. Arch Gynecol Obstet. 2015;291(1):31-8.
  3. [12]12. Levario-Carrillo M, Avitia M, Tufiño-Olivares E, Trevizo E, Corral-Terrazas M, Reza-López S. Body 306 composition of patients with hypertensive complications during pregnancy. Hypertens Pregnancy 307 [Internet]. 2006;25(3):259-69. 308 309 310
  4. [13]13. Da Silva EG, De Barros Leite Carvalhaes MA, Hirakawa HS, Da Silva EG, Peraçoli JC. Bioimpedance in pregnant women with preeclampsia. Hypertens Pregnancy [Internet]. 2010;29(4):357-65.
  5. [14]14. Berlit S, Tuschy B, Stojakowits M, Weiss C, Leweling H, Sütterlin M, et al. Bioelectrical impedance 311 analysis in pregnancy: Reference ranges. In Vivo (Brooklyn). 2013;27(6):851-4. 312
  6. [15]15. Valensise H, Andreoli A, Lello S, Magnani F, Romanini C, De Lorenzo A. Multifrequency bioelectrical 313 impedance analysis in women with a normal and hypertensive pregnancy. Am J Clin Nutr. 314 2000;72(3):780-3. 315
  7. [16]16. Ghezzi F, Franchi M, Balestreri D, Lischetti B, Mele MC, Alberico S, et al. Bioelectrical impedance 316 analysis during pregnancy and neonatal birth weight. Eur J Obstet Gynecol Reprod Biol [Internet]. 317 2001;98(2):171-6. 318
  8. [18]18. Yasuda R, Takeuchi K, Funakoshi T, Maruo T. Bioelectrical impedance analysis in the clinical 321 management of preeclamptic women with edema. J Perinat Med. 2003;31(4):275-80. 322
  9. [19]19. Mardones-Santander F, Salazar G, Rosso P, Villarroel L. Maternal body composition near term and 323 birth weight. Obstet Gynecol. 1998;91(6):873-7. 324
  10. [20]20. Sanin Aguirre LH, Reza-López S, Levario-Carrillo M. Relation between maternal body composition 325 and birth weight. Biol Neonate. 2004;86(1):55-62. 326
  11. [21]21. Rodríguez Atristain A, Miranda-alatriste P, Sánchez-hernández O, Rodríguez-arellano M, Sánchez327 328 329 330 331 332 trampe B. Vectores de impedancia bioeléctrica para analizar la composición corporal de mujeres mexicanas embarazadas Bioelectrical impedance vector analysis for mexican pregnant ' s body. Rev Espec Médico-Quirúrgicas. 2016;21(2):55-64.
  12. [22]22. Lukaski HC, Hall CB, Siders WA. Assessment of change in hydration in women during pregnancy and postpartum with bioelectrical impedance vectors. Nutrition. 2007;23(7-8):543-50.
  13. [23]23. Piccoli A, Rossi B, Pillon L, Bucciante G. A new method for monitoring body fluid variation by 333 bioimpedance analysis: The RXc graph. Vol. 46, Kidney international. 1994. 334
  14. [24]24. Marini E, Campa F, Buffa R, Stagi S, Matias CN, Toselli S, et al. Phase angle and bioelectrical 335 impedance vector analysis in the evaluation of body composition in athletes. Clin Nutr. 336 2020;39(2):447-54. 337
  15. [25]25. Marini E, Sergi G, Succa V, Saragat B, Sarti S, Coin A, et al. Efficacy of specific bioelectrical 338 impedance vector analysis (BIVA) for assessing body composition in the elderly. J Nutr Health Aging. 339 2013;17(6):515-21. 340
  16. [26]26. Buffa R, Saragat B, Cabras S, Rinaldi AC, Marini E. Accuracy of Specific BIVA for the Assessment of 341 Body Composition in the United States Population. PLoS One. 2013;8(3):1-10. 342
  17. [27]27. Massari F, Scicchitano P, Potenza A, Sassara M, Sanasi M, Liccese M, et al. Supraventricular 343 tachycardia, pregnancy, and water: A new insight in lifesaving treatment of rhythm disorders. Ann 344 Noninvasive Electrocardiol. 2018;23(3):1-5. 345
  18. [28]28. World Medical Association. World Medical Association declaration of Helsinki: Ethical principles for 346 medical research involving human subjects. Vol. 310, JAMA - Journal of the American Medical 347 Association. American Medical Association; 2013. p. 2191-4. 348 349 350
  19. [30]30. Peebles L, Beverley N. Adultdata: The Handbook of Adult Anthropometric and Strength 351 Measurements. Data for Design Safety by Laura Peebles and Beverley Norris 1998, 404 pages, free 352 to UK addresses UK: Department of Trade and Industry (URN 98/736) [Internet]. Vol. 7, Ergonomics 353 in Design: The Quarterly of Human Factors Applications. SAGE Publications; 1999. 32-34 p. 354
  20. [33]33. Marini E, Buffa R, Saragat B, Coin A, Toffanello ED, Berton L, et al. The potential of classic and 359 specific bioelectrical impedance vector analysis for the assessment of sarcopenia and sarcopenic 360 obesity. Clin Interv Aging. 2012;7:585-91. 361
  21. [34]34. Wells JC, Williams JE, Ward LC, Fewtrell MS. Utility of specific bioelectrical impedance vector 362 analysis for the assessment of body composition in children. Clin Nutr. 2021;40(3):1147-54. 363 364 <!-- image --> <!-- image --> Table 1. Results of the longitudinal study on 12 healthy pregnant women: difference ( ∆ ) between weeks 28 th -32 nd and 11 th -15 th of anthropometric and bioelectrical variables (mean and SD) and significance in bold. Table 2. Results of cross-sectional study on anthropometric and bioelectrical variables (mean and SD) of healthy pregnant women during weeks 12 th -13 th , weeks-30 th -31 st , and within two months postpartum. Significance in bold.

Authors
Moroni, A., Vardè, C., Giustetto, A., Stagi, S., Marini, E., & Micheletti Cremasco, M.
Affiliations
  • University of Turin (IT)
  • Ospedale Civile Edoardo Agnelli (IT)
  • University of Cagliari (IT)
Venue
European Journal of Clinical Nutrition
Published
2021-08-06
Volume
76
Issue
4
Pages
604-609
ISSN
  • 0954-3007 (ISSN-L)
  • 1476-5640
OpenAlex
W3193141848
Cited by
13
References
31
Citations by year
2026: 3 · 2025: 3 · 2024: 3 · 2023: 3 · 2022: 1
FWCI
1.10
Type
journal article
Language
en
Open access
Locations
  • European Journal of Clinical Nutrition (publishedVersion)
  • PubMed (publishedVersion)
  • Institutional Research Information System University of Turin (University of Turin) (submittedVersion, other-oa)
  • UNICA IRIS Institutional Research Information System (University of Cagliari) (submittedVersion, other-oa)
Topics
  • Health Sciences › Medicine › Physiology › Body Composition Measurement Techniques
  • Health Sciences › Medicine › Obstetrics and Gynecology › Pregnancy and preeclampsia studies
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Electrical and Bioimpedance Tomography
Keywords
bioelectrical impedance vector analysis, body composition, pregnancy, total body water, extracellular water, intracellular water, fat mass, hydration, phase angle, postpartum period, physiological changes in pregnancy
MeSH terms
Body Composition, Female, Humans, Pregnancy, Electric Impedance

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review