3D single-molecule super-resolution microscopy with a tilted light sheet
Open accessThe DOI matches its Crossref record.
Abstract
Tilted light sheet microscopy with 3D point spread functions (TILT3D) combines a novel, tilted light sheet illumination strategy with long axial range point spread functions (PSFs) for low-background, 3D super-localization of single molecules as well as 3D super-resolution imaging in thick cells. Because the axial positions of the single emitters are encoded in the shape of each single-molecule image rather than in the position or thickness of the light sheet, the light sheet need not be extremely thin. TILT3D is built upon a standard inverted microscope and has minimal custom parts. The result is simple and flexible 3D super-resolution imaging with tens of nm localization precision throughout thick mammalian cells. We validate TILT3D for 3D super-resolution imaging in mammalian cells by imaging mitochondria and the full nuclear lamina using the double-helix PSF for single-molecule detection and the recently developed tetrapod PSFs for fiducial bead tracking and live axial drift correction.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Super-resolution microscopy demystified
Schermelleh, L., Ferrand, A., Huser, T., Eggeling, C., Sauer, M., Biehlmaier, O., & Drummen, G. P. C. (2019) · Nature Cell Biology · doi:10.1038/s41556-018-0251-8 · Cited by 1,211
Light sheet fluorescence microscopy
Stelzer, E. H. K., Strobl, F., Chang, B.-J., Preusser, F., Preibisch, S., McDole, K., & Fiolka, R. (2021) · Nature Reviews Methods Primers · doi:10.1038/s43586-021-00069-4 · Cited by 334
Light-Sheet Microscopy in Neuroscience
Hillman, E. M. C., Voleti, V., Li, W., & Yu, H. (2019) · Annual Review of Neuroscience · doi:10.1146/annurev-neuro-070918-050357 · Cited by 188
“Multiple studies have also demonstrated light-sheet approaches for subcellular imaging (Gustavsson et al. 2018, Liu et al. 2018).”
BackgroundMöckl, L., & Moerner, W. E. (2020) · Journal of the American Chemical Society · doi:10.1021/jacs.0c08178 · Cited by 181
Self-citationIn vivo NIR-II structured-illumination light-sheet microscopy
Wang, F., Ma, Z., Zhong, Y., Salazar, F., Xu, C., Ren, F., Qu, L., Wu, A. M., & Dai, H. (2021) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2023888118 · Cited by 85
“Scanning structured illumination (2, 11–14, 23) and single-molecule localization (66, 67) have enabled LSM with subdiffraction limited resolution.”
Background
Metadata
- Authors
- Gustavsson, A.-K., Petrov, P. N., Lee, M. Y., Shechtman, Y., & Moerner, W. E.
- Venue
- Nature Communications
- Published
- 2018-01-09
- Volume
- 9
- Issue
- 1
- Pages
- 123-123
- ISSN
- 2041-1723 (ISSN-L)
- OpenAlex
- W2953148540
- Cited by
- 193
- References
- 0
- FWCI
- 13.32
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: 3D single-molecule super-resolution microscopy with a tilted light sheet. https://app.cochat.ai/papers/10.1038/s41467-017-02563-4
- The paper
- Gustavsson, A.-K., Petrov, P. N., Lee, M. Y., Shechtman, Y., & Moerner, W. E. (2018). 3D single-molecule super-resolution microscopy with a tilted light sheet. Nature Communications. https://doi.org/10.1038/s41467-017-02563-4
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.