The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Imaging and writing magnetic domains in the non-collinear antiferromagnet Mn3Sn
Open accessAbstract
Non-collinear antiferromagnets are revealing many unexpected phenomena and they became crucial for the field of antiferromagnetic spintronics. To visualize and prepare a well-defined domain structure is of key importance. The spatial magnetic contrast, however, remains extraordinarily difficult to be observed experimentally. Here, we demonstrate a magnetic imaging technique based on a laser induced local thermal gradient combined with detection of the anomalous Nernst effect. We employ this method in one the most actively studied representatives of this class of materials—Mn 3 Sn. We demonstrate that the observed contrast is of magnetic origin. We further show an algorithm to prepare a well-defined domain pattern at room temperature based on heat assisted recording principle. Our study opens up a prospect to study spintronics phenomena in non-collinear antiferromagnets with spatial resolution.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Large anomalous Hall effect in a non-collinear antiferromagnet at room temperature
Nakatsuji, S., Kiyohara, N., & Higo, T. (2015) · Nature · doi:10.1038/nature15723 · Cited by 1,721
Nayak, A. K., Fischer, J. E., Sun, Y., Yan, B., Karel, J., Komarek, A. C., Shekhar, C., Kumar, N., Schnelle, W., Kübler, J., et al. (2016) · Science Advances · doi:10.1126/sciadv.1501870 · Cited by 905
Self-citationLarge anomalous Nernst effect at room temperature in a chiral antiferromagnet
Ikhlas, M., Tomita, T., Koretsune, T., Suzuki, M.-T., Nishio-Hamane, D., Arita, R., Otani, Y., & Nakatsuji, S. (2017) · Nature Physics · doi:10.1038/nphys4181 · Cited by 746
Topological Weyl semimetals in the chiral antiferromagnetic materials Mn3Ge and Mn3Sn
Yang, H., Sun, Y., Zhang, Y., Shi, W.-J., Parkin, S. S. P., & Yan, B. (2017) · New Journal of Physics · doi:10.1088/1367-2630/aa5487 · Cited by 400
Cited by
Mucosal vaccines — fortifying the frontiers
Lavelle, E. C., & Ward, R. W. (2022) · Nature Reviews Immunology · doi:10.1038/s41577-021-00583-2 · Cited by 752
Anomalous Hall antiferromagnets
Šmejkal, L., MacDonald, A. H., Sinova, J., Nakatsuji, S., & Jungwirth, T. (2022) · Nature Reviews Materials · doi:10.1038/s41578-022-00430-3 · Cited by 500
Self-citationOceanic Hitchhikers – Assessing Pathogen Risks from Marine Microplastic
Bowley, J., Baker-Austin, C., Porter, A., Hartnell, R., & Lewis, C. (2021) · Trends in Microbiology · doi:10.1016/j.tim.2020.06.011 · Cited by 497
Analytic Pearson residuals for normalization of single-cell RNA-seq UMI data
Lause, J., Berens, P., & Kobak, D. (2021) · Genome Biology · doi:10.1186/s13059-021-02451-7 · Cited by 195
Hasegawa, T., & Nakaoka, M. (2021) · Environmental Pollution · doi:10.1016/j.envpol.2021.116468 · Cited by 176
Metadata
- Authors
- Reichlova, H., Janda, T., Godinho, J., Markou, A., Kriegner, D., Schlitz, R., Zelezny, J., Soban, Z., Bejarano, M., Schultheiss, H., Nemec, P., Jungwirth, T., Felser, C., Wunderlich, J., & Goennenwein, S. T. B.
- Venue
- Nature Communications
- Published
- 2019-11-29
- Volume
- 10
- Issue
- 1
- Pages
- 5459-5459
- ISSN
- 2041-1723 (ISSN-L)
- OpenAlex
- W2990890155
- Cited by
- 182
- References
- 4
- FWCI
- 14.11
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Imaging and writing magnetic domains in the non-collinear antiferromagnet Mn3Sn. https://app.cochat.ai/papers/10.1038/s41467-019-13391-z
- The paper
- Reichlova, H., Janda, T., Godinho, J., Markou, A., Kriegner, D., Schlitz, R., Zelezny, J., Soban, Z., Bejarano, M., Schultheiss, H., Nemec, P., Jungwirth, T., Felser, C., Wunderlich, J., & Goennenwein, S. T. B. (2019). Imaging and writing magnetic domains in the non-collinear antiferromagnet Mn3Sn. Nature Communications. https://doi.org/10.1038/s41467-019-13391-z
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.