CoChat

First-in-human robotic supermicrosurgery using a dedicated microsurgical robot for treating breast cancer-related lymphedema: a randomized pilot trial

Open access
van Mulken, Tom J. M., Schols, Rutger M., Scharmga, Andrea M. J., Winkens, Bjorn, Cau, Raimondo, Schoenmakers, Ferry B. F., Qiu, Shan S., van der Hulst, René R. W. J., MicroSurgical Robot Research Group, Keuter, Xavier H. A., Lauwers, Thomas M. A. S., Piatkowski, Andrzej A., Hommes, Juliette E., Deibel, Dionne S., Budo, Jessie E. M., Scheerhoorn, Jai, Rijkx, Maud E. P. · 2020 · Nature Communications
Cited by 206

The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.

Abstract

Advancements in reconstructive microsurgery have evolved into supermicrosurgery; connecting vessels with diameter between 0.3 and 0.8 mm for reconstruction of lymphatic flow and vascularized tissue transplantation. Supermicrosurgery is limited by the precision and dexterity of the surgeon’s hands. Robot assistance can help overcome these human limitations, thereby enabling a breakthrough in supermicrosurgery. We report the first-in-human study of robot-assisted supermicrosurgery using a dedicated microsurgical robotic platform. A prospective randomized pilot study is conducted comparing robot-assisted and manual supermicrosurgical lymphatico-venous anastomosis (LVA) in treating breast cancer-related lymphedema. We evaluate patient outcome at 1 and 3 months post surgery, duration of the surgery, and quality of the anastomosis. At 3 months, patient outcome improves. Furthermore, a steep decline in duration of time required to complete the anastomosis is observed in the robot-assisted group (33–16 min). Here, we report the feasibility of robot-assisted supermicrosurgical anastomosis in LVA, indicating promising results for the future of reconstructive supermicrosurgery.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1038/s41467-019-14188-w

Cites

14 of 14 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 14 references

Cited by

See all 206

Metadata

Authors
van Mulken, T. J. M., Schols, R. M., Scharmga, A. M. J., Winkens, B., Cau, R., Schoenmakers, F. B. F., Qiu, S. S., van der Hulst, R. R. W. J., MicroSurgical Robot Research Group, Keuter, X. H. A., Lauwers, T. M. A. S., Piatkowski, A. A., Hommes, J. E., Deibel, D. S., Budo, J. E. M., Scheerhoorn, J., & Rijkx, M. E. P.
Venue
Nature Communications
Published
2020-02-11
Volume
11
Issue
1
Pages
757-757
ISSN
2041-1723 (ISSN-L)
OpenAlex
W3005613386
Cited by
206
References
14
FWCI
7.62
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: First-in-human robotic supermicrosurgery using a dedicated microsurgical robot for treating breast cancer-related lymphedema: a randomized pilot trial. https://app.cochat.ai/papers/10.1038/s41467-019-14188-w
The paper
van Mulken, T. J. M., Schols, R. M., Scharmga, A. M. J., Winkens, B., Cau, R., Schoenmakers, F. B. F., Qiu, S. S., van der Hulst, R. R. W. J., MicroSurgical Robot Research Group, Keuter, X. H. A., Lauwers, T. M. A. S., Piatkowski, A. A., Hommes, J. E., Deibel, D. S., Budo, J. E. M., Scheerhoorn, J., & Rijkx, M. E. P. (2020). First-in-human robotic supermicrosurgery using a dedicated microsurgical robot for treating breast cancer-related lymphedema: a randomized pilot trial. Nature Communications. https://doi.org/10.1038/s41467-019-14188-w

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.