The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
H2S-activatable near-infrared afterglow luminescent probes for sensitive molecular imaging in vivo
Open accessAbstract
Afterglow luminescent probes with high signal-to-background ratio show promise for in vivo imaging; however, such probes that can be selectively delivered into target sites and switch on afterglow luminescence remain limited. We optimize an organic electrochromic material and integrate it into near-infrared (NIR) photosensitizer (silicon 2,3-naphthalocyanine bis(trihexylsilyloxide) and (poly[2-methoxy-5-(2-ethylhexyloxy)-1,4-phenylenevinylene]) containing nanoparticles, developing an H 2 S-activatable NIR afterglow probe (F12+-ANP). F12+-ANP displays a fast reaction rate (1563 ± 141 M−1 s−1) and large afterglow turn-on ratio (~122-fold) toward H 2 S, enabling high-sensitivity and -specificity measurement of H 2 S concentration in bloods from healthy persons, hepatic or colorectal cancer patients. We further construct a hepatic-tumor-targeting and H 2 S-activatable afterglow probe (F12+-ANP-Gal) for noninvasive, real-time imaging of tiny subcutaneous HepG2 tumors (<3 mm in diameter) and orthotopic liver tumors in mice. Strikingly, F12+-ANP-Gal accurately delineates tumor margins in excised hepatic cancer specimens, which may facilitate intraoperative guidance of hepatic cancer surgery.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Ma, H., Peng, Q., An, Z., Huang, W., & Shuai, Z. (2019) · Journal of the American Chemical Society · doi:10.1021/jacs.8b11224 · Cited by 613
Impairment of an endothelial NAD(+)-H2S signaling network is a reversible cause of vascular aging
Das, A., Huang, G. X., Bonkowski, M. S., Longchamp, A., Li, C., Schultz, M. B., Kim, L.-J., Osborne, B., Joshi, S., Lu, Y., et al. (2018) · Cell · doi:10.1016/j.cell.2018.02.008 · Cited by 496
Self-citation
Cited by
Wang, Y., Gao, H., Yang, J., Fang, M., Ding, D., Tang, B. Z., & Li, Z. (2021) · Advanced Materials · doi:10.1002/adma.202007811 · Cited by 493
Nanoparticles with ultrasound-induced afterglow luminescence for tumour-specific theranostics
Xu, C., Huang, J., Jiang, Y., He, S., Zhang, C., & Pu, K. (2022) · Nature Biomedical Engineering · doi:10.1038/s41551-022-00978-z · Cited by 267
Fluorescent probes for the detection of disease-associated biomarkers
Dou, W.-T., Han, H.-H., Sedgwick, A. C., Zhu, G.-B., Zang, Y., Yang, X.-R., Yoon, J., James, T. D., Li, J., & He, X.-P. (2022) · Science Bulletin · doi:10.1016/j.scib.2022.01.014 · Cited by 266
Yang, Y., Liu, Y., Weng, J., Wen, X., Liu, Y., & Ye, D. (2024) · Biomaterials · doi:10.1016/j.biomaterials.2023.122454 · Cited by 25
Self-citation
Metadata
- Authors
- Wu, L., Ishigaki, Y., Hu, Y., Sugimoto, K., Zeng, W., Harimoto, T., Sun, Y., He, J., Suzuki, T., Jiang, X., Chen, H.-Y., & Ye, D.
- Venue
- Nature Communications
- Published
- 2020-01-23
- Volume
- 11
- Issue
- 1
- Pages
- 446-446
- ISSN
- 2041-1723 (ISSN-L)
- OpenAlex
- W3003148976
- Cited by
- 251
- References
- 2
- FWCI
- 10.92
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: H2S-activatable near-infrared afterglow luminescent probes for sensitive molecular imaging in vivo. https://app.cochat.ai/papers/10.1038/s41467-020-14307-y
- The paper
- Wu, L., Ishigaki, Y., Hu, Y., Sugimoto, K., Zeng, W., Harimoto, T., Sun, Y., He, J., Suzuki, T., Jiang, X., Chen, H.-Y., & Ye, D. (2020). H2S-activatable near-infrared afterglow luminescent probes for sensitive molecular imaging in vivo. Nature Communications. https://doi.org/10.1038/s41467-020-14307-y
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.