Organic NIR-II molecule with long blood half-life for in vivo dynamic vascular imaging
Open accessAbstract
Real-time monitoring of vessel dysfunction is of great significance in preclinical research. Optical bioimaging in the second near-infrared (NIR-II) window provides advantages including high resolution and fast feedback. However, the reported molecular dyes are hampered by limited blood circulation time (~ 5–60 min) and short absorption and emission wavelength, which impede the accurate long-term monitoring. Here, we report a NIR-II molecule (LZ-1105) with absorption and emission beyond 1000 nm. Thanks to the long blood circulation time (half-life of 3.2 h), the fluorophore is used for continuous real-time monitoring of dynamic vascular processes, including ischemic reperfusion in hindlimbs, thrombolysis in carotid artery and opening and recovery of the blood brain barrier (BBB). LZ-1105 provides an approach for researchers to assess vessel dysfunction due to the long excitation and emission wavelength and long-term blood circulation properties.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Cyanine dyes with varied energy gaps have been designed through structure modifications that allowed the development of fluorophores with emission greater than 1000 nm.
“Cyanine dyes with varied energy gaps have been designed through structure modifications that allowed the development of fluorophores with emission greater than 1000 nm.34−36”
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
The citation lists haven’t been fetched yet
References 57 · Cited by 374
- Authors
- Li, B., Zhao, M., Feng, L., Dou, C., Ding, S., Zhou, G., Lu, L., Zhang, H., Chen, F., Li, X., Li, G., Zhao, S., Jiang, C., Wang, Y., Zhao, D., Cheng, Y., & Zhang, F.
- Affiliations
- Fudan University (CN)
- Shanghai Jiao Tong University (CN)
- Corresponding author
- Zhang, Fan
- ORCID
- Venue
- Nature Communications
- Published
- 2020-06-18
- Volume
- 11
- Issue
- 1
- Pages
- 3102-3102
- ISSN
- 2041-1723 (ISSN-L)
- PMC
- PMC7303218
- OpenAlex
- W3036418258
- Cited by
- 374
- References
- 57
- Citations by year
- 2026: 33 · 2025: 51 · 2024: 70 · 2023: 68 · 2022: 73 · 2021: 60 · 2020: 19
- FWCI
- 26.77
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Locations
- Nature Communications (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- RePEc: Research Papers in Economics (submittedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Griffith Research Online (submittedVersion, cc-by)
- Funders
- Chinese Ministry of Science and Technology | Department of S and T for Social Development (2017YFA0207303)
- National Natural Science Foundation of China (21725502, 51961145403)
- Science and Technology Commission of Shanghai Municipality (17JC1400100, 19490713100)
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Optical Imaging and Spectroscopy Techniques
- Physical Sciences › Materials Science › Materials Chemistry › Luminescence and Fluorescent Materials
- Physical Sciences › Chemistry › Spectroscopy › Molecular Sensors and Ion Detection
- Keywords
- NIR-II fluorescence imaging, vascular imaging, ischemia-reperfusion injury, thrombolysis, blood-brain barrier, blood-brain barrier opening, carotid artery, hindlimb ischemia, molecular dyes, real-time monitoring
- MeSH terms
- Animals, Carotid Arteries, Female, Fluorescent Dyes, Hindlimb, Humans, Mice, Nude, Thrombosis, Vascular Diseases, Reperfusion Injury, Human Umbilical Vein Endothelial Cells
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review