Zero-bias mid-infrared graphene photodetectors with bulk photoresponse and calibration-free polarization detection
Open accessAbstract
Bulk photovoltaic effect (BPVE), featuring polarization-dependent uniform photoresponse at zero external bias, holds potential for exceeding the Shockley-Queisser limit in the efficiency of existing opto-electronic devices. However, the implementation of BPVE has been limited to the naturally existing materials with broken inversion symmetry, such as ferroelectrics, which suffer low efficiencies. Here, we propose metasurface-mediated graphene photodetectors with cascaded polarization-sensitive photoresponse under uniform illumination, mimicking an artificial BPVE. With the assistance of non-centrosymmetric metallic nanoantennas, the hot photocarriers in graphene gain a momentum upon their excitation and form a shift current which is nonlocal and directional. Thereafter, we demonstrate zero-bias uncooled mid-infrared photodetectors with three orders higher responsivity than conventional BPVE and a noise equivalent power of 0.12 nW Hz−1/2. Besides, we observe a vectorial photoresponse which allows us to detect the polarization angle of incident light with a single device. Our strategy opens up alternative possibilities for scalable, low-cost, multifunctional infrared photodetectors.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Bias-free current generation has been demonstrated in hybrid gold-graphene systems with symmetry-broken nanostructures of different designer in-plane spatial symmetries.
“Bias-free current generation has been demonstrated in hybrid gold-graphene systems with -broken nanostructures of different designer in-plane spatial symmetries263,264.”
From Ultrafast terahertz emission from emerging symmetry-broken materials (2023) · cites this paper as [263]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
The citation lists haven’t been fetched yet
References 63 · Cited by 233
Research works printed but not linked: 1
- [11]Sturman, P. J. Photovoltaic and Photo-refractive Effects in Noncentrosymmetric Materials Vol. 8 (CRC Press, 1992).
- Authors
- Wei, J., Li, Y., Wang, L., Liao, W., Dong, B., Xu, C., Zhu, C., Ang, K.-W., Qiu, C.-W., & Lee, C.
- Affiliations
- National University of Singapore (SG)
- State Key Laboratory of Modern Optical Instruments (CN)
- Corresponding author
- Qiu, Cheng-Wei
- Lee, Chengkuo
- ORCID
- Venue
- Nature Communications
- Published
- 2020-12-17
- Volume
- 11
- Issue
- 1
- Pages
- 6404-6404
- ISSN
- 2041-1723 (ISSN-L)
- PMC
- PMC7747747
- OpenAlex
- W3112814004
- Cited by
- 233
- References
- 63
- Citations by year
- 2026: 33 · 2025: 52 · 2024: 49 · 2023: 37 · 2022: 39 · 2021: 22 · 2020: 1
- FWCI
- 9.63
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Locations
- Nature Communications (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- National University of Singapore (submittedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Funders
- National Research Foundation
- National Research Foundation Singapore (R-263000C24281)
- Topics
- Physical Sciences › Materials Science › Materials Chemistry › Graphene research and applications
- Physical Sciences › Engineering › Biomedical Engineering › Plasmonic and Surface Plasmon Research
- Physical Sciences › Materials Science › Electronic, Optical and Magnetic Materials › Metamaterials and Metasurfaces Applications
- Keywords
- bulk photovoltaic effect, graphene photodetectors, mid-infrared photodetection, polarization detection, shift current, metasurfaces, zero-bias photodetection, uncooled photodetectors, noise equivalent power
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review