The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
High-speed three-dimensional photoacoustic computed tomography for preclinical research and clinical translation
Open accessAbstract
Photoacoustic computed tomography (PACT) has generated increasing interest for uses in preclinical research and clinical translation. However, the imaging depth, speed, and quality of existing PACT systems have previously limited the potential applications of this technology. To overcome these issues, we developed a three-dimensional photoacoustic computed tomography (3D-PACT) system that features large imaging depth, scalable field of view with isotropic spatial resolution, high imaging speed, and superior image quality. 3D-PACT allows for multipurpose imaging to reveal detailed angiographic information in biological tissues ranging from the rodent brain to the human breast. In the rat brain, we visualize whole brain vasculatures and hemodynamics. In the human breast, an in vivo imaging depth of 4 cm is achieved by scanning the breast within a single breath hold of 10 s. Here, we introduce the 3D-PACT system to provide a unique tool for preclinical research and an appealing prototype for clinical translation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Structural absorption by barbule microstructures of super black bird of paradise feathers
McCoy, D. E., Feo, T., Harvey, T. A., & Prum, R. O. (2018) · Nature Communications · doi:10.1038/s41467-017-02088-w · Cited by 7,424
Mapping oxygen concentration in the awake mouse brain
Lyons, D. G., Parpaleix, A., Roche, M., & Charpak, S. (2016) · eLife · doi:10.7554/elife.12024 · Cited by 165
Cited by
Stimuli-Responsive Polymer-Based Nanosystems for Cancer Theranostics
Wei, D., Sun, Y., Zhu, H., & Fu, Q. (2023) · ACS Nano · doi:10.1021/acsnano.3c06019 · Cited by 303
Metadata
- Authors
- Lin, L., Hu, P., Tong, X., Na, S., Cao, R., Yuan, X., Garrett, D. C., Shi, J., Maslov, K., & Wang, L. V.
- Venue
- Nature Communications
- Published
- 2021-02-09
- Volume
- 12
- Issue
- 1
- Pages
- 882-882
- ISSN
- 2041-1723 (ISSN-L)
- OpenAlex
- W3126411932
- Cited by
- 200
- References
- 2
- FWCI
- 9.38
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: High-speed three-dimensional photoacoustic computed tomography for preclinical research and clinical translation. https://app.cochat.ai/papers/10.1038/s41467-021-21232-1
- The paper
- Lin, L., Hu, P., Tong, X., Na, S., Cao, R., Yuan, X., Garrett, D. C., Shi, J., Maslov, K., & Wang, L. V. (2021). High-speed three-dimensional photoacoustic computed tomography for preclinical research and clinical translation. Nature Communications. https://doi.org/10.1038/s41467-021-21232-1
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.