Imaging-based spectrometer-less optofluidic biosensors based on dielectric metasurfaces for detecting extracellular vesicles
Open accessThe DOI matches its Crossref record; 49 of the 49 references it cites were found in a registry or an index.
Abstract
Biosensors are indispensable tools for public, global, and personalized healthcare as they provide tests that can be used from early disease detection and treatment monitoring to preventing pandemics. We introduce single-wavelength imaging biosensors capable of reconstructing spectral shift information induced by biomarkers dynamically using an advanced data processing technique based on an optimal linear estimator. Our method achieves superior sensitivity without wavelength scanning or spectroscopy instruments. We engineered diatomic dielectric metasurfaces supporting bound states in the continuum that allows high-quality resonances with accessible near-fields by in-plane symmetry breaking. The large-area metasurface chips are configured as microarrays and integrated with microfluidics on an imaging platform for real-time detection of breast cancer extracellular vesicles encompassing exosomes. The optofluidic system has high sensing performance with nearly 70 1/RIU figure-of-merit enabling detection of on average 0.41 nanoparticle/µm 2 and real-time measurements of extracellular vesicles binding from down to 204 femtomolar solutions. Our biosensors provide the robustness of spectrometric approaches while substituting complex instrumentation with a single-wavelength light source and a complementary-metal-oxide-semiconductor camera, paving the way toward miniaturized devices for point-of-care diagnostics.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Mathieu, M., Martin-Jaular, L., Lavieu, G., & Théry, C. (2019) · Nature Cell Biology · doi:10.1038/s41556-018-0250-9 · Cited by 3,737
Hsu, C. W., Zhen, B., Stone, A. D., Joannopoulos, J. D., & Soljačić, M. (2016) · Nature Reviews Materials · doi:10.1038/natrevmats.2016.48 · Cited by 3,468
Optically resonant dielectric nanostructures
Kuznetsov, A. I., Miroshnichenko, A. E., Brongersma, M. L., Kivshar, Y. S., & Luk’yanchuk, B. (2016) · Science · doi:10.1126/science.aag2472 · Cited by 2,884
Self-citationAsymmetric Metasurfaces with High- Q Resonances Governed by Bound States in the Continuum
Koshelev, K., Lepeshov, S., Liu, M., Bogdanov, A., & Kivshar, Y. (2018) · Physical Review Letters · doi:10.1103/physrevlett.121.193903 · Cited by 2,114
Self-citationTetraspanins in Extracellular Vesicle Formation and Function
Andreu, Z., & Yáñez-Mó, M. (2014) · Frontiers in Immunology · doi:10.3389/fimmu.2014.00442 · Cited by 1,487
Label-free detection and molecular profiling of exosomes with a nano-plasmonic sensor
Im, H., Shao, H., Park, Y. I., Peterson, V. M., Castro, C. M., Weissleder, R., & Lee, H. (2014) · Nature Biotechnology · doi:10.1038/nbt.2886 · Cited by 1,321
Recent advances in planar optics: from plasmonic to dielectric metasurfaces
Genevet, P., Capasso, F., Aieta, F., Khorasaninejad, M., & Devlin, R. (2017) · Optica · doi:10.1364/optica.4.000139 · Cited by 1,239
Ultrasensitive hyperspectral imaging and biodetection enabled by dielectric metasurfaces
Yesilkoy, F., Arvelo, E. R., Jahani, Y., Liu, M., Tittl, A., Cevher, V., Kivshar, Y., & Altug, H. (2019) · Nature Photonics · doi:10.1038/s41566-019-0394-6 · Cited by 1,015
Self-citationFunctional Meta-Optics and Nanophotonics Governed by Mie Resonances
Kruk, S., & Kivshar, Y. (2017) · ACS Photonics · doi:10.1021/acsphotonics.7b01038 · Cited by 643
Self-citationNanophotonics: Shrinking light-based technology
Koenderink, A. F., Alù, A., & Polman, A. (2015) · Science · doi:10.1126/science.1261243 · Cited by 598
Cited by
Advances and applications of nanophotonic biosensors
Altug, H., Oh, S.-H., Maier, S. A., & Homola, J. (2022) · Nature Nanotechnology · doi:10.1038/s41565-021-01045-5 · Cited by 882
Self-citationApplications of bound states in the continuum in photonics
Kang, M., Liu, T., Chan, C. T., & Xiao, M. (2023) · Nature Reviews Physics · doi:10.1038/s42254-023-00642-8 · Cited by 458
Metasurface Micro/Nano-Optical Sensors: Principles and Applications
Qin, J., Jiang, S., Wang, Z., Cheng, X., Li, B., Shi, Y., Tsai, D. P., Liu, A. Q., Huang, W., & Zhu, W. (2022) · ACS Nano · doi:10.1021/acsnano.2c03310 · Cited by 359
Resonant leaky modes in all-dielectric metasystems: Fundamentals and applications
Huang, L., Xu, L., Powell, D. A., Padilla, W. J., & Miroshnichenko, A. E. (2023) · Physics Reports · doi:10.1016/j.physrep.2023.01.001 · Cited by 328
Zhang, Z., Wang, Z., Zhang, C., Yao, Z., Zhang, S., Wang, R., Tian, Z., Han, J., Chang, C., Lou, J., et al. (2024) · Advanced Materials · doi:10.1002/adma.202308453 · Cited by 309
Optical bound states in the continuum in periodic structures: mechanisms, effects, and applications
Wang, J., Li, P., Zhao, X., Qian, Z., Wang, X., Wang, F., Zhou, X., Han, D., Peng, C., Shi, L., et al. (2024) · Photonics Insights · doi:10.3788/pi.2024.r01 · Cited by 211
“The realm of high-Q resonators has realized high-sensitivity refractive index (RI) sensing across chemical and biological processes, as evidenced by various studies [229 – 239] .”
BackgroundKühner, L., Wendisch, F. J., Antonov, A. A., Bürger, J., Hüttenhofer, L., de S. Menezes, L., Maier, S. A., Gorkunov, M. V., Kivshar, Y., & Tittl, A. (2023) · Light: Science & Applications · doi:10.1038/s41377-023-01295-z · Cited by 200
Self-citationLuo, M., Zhou, Y., Zhao, X., Guo, Z., Li, Y., Wang, Q., Liu, J., Luo, W., Shi, Y., Liu, A. Q., et al. (2024) · ACS Nano · doi:10.1021/acsnano.3c11994 · Cited by 171
Wavelength-multiplexed hook nanoantennas for machine learning enabled mid-infrared spectroscopy
Ren, Z., Zhang, Z., Wei, J., Dong, B., & Lee, C. (2022) · Nature Communications · doi:10.1038/s41467-022-31520-z · Cited by 132
Metadata
- Authors
- Jahani, Y., Arvelo, E. R., Yesilkoy, F., Koshelev, K., Cianciaruso, C., De Palma, M., Kivshar, Y., & Altug, H.
- Venue
- Nature Communications
- Published
- 2021-05-31
- Volume
- 12
- Issue
- 1
- Pages
- 3246-3246
- ISSN
- 2041-1723 (ISSN-L)
- OpenAlex
- W3164835394
- Cited by
- 304
- References
- 49
- FWCI
- 11.21
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.