The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Highly sensitive active pixel image sensor array driven by large-area bilayer MoS2 transistor circuitry
Open accessAbstract
Various large-area growth methods for two-dimensional transition metal dichalcogenides have been developed recently for future electronic and photonic applications. However, they have not yet been employed for synthesizing active pixel image sensors. Here, we report on an active pixel image sensor array with a bilayer MoS 2 film prepared via a two-step large-area growth method. The active pixel of image sensor is composed of 2D MoS 2 switching transistors and 2D MoS 2 phototransistors. The maximum photoresponsivity (Rph) of the bilayer MoS 2 phototransistors in an 8 × 8 active pixel image sensor array is statistically measured as high as 119.16 A W−1. With the aid of computational modeling, we find that the main mechanism for the high Rph of the bilayer MoS 2 phototransistor is a photo-gating effect by the holes trapped at subgap states. The image-sensing characteristics of the bilayer MoS 2 active pixel image sensor array are successfully investigated using light stencil projection.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
In situ click chemistry generation of cyclooxygenase-2 inhibitors
Bhardwaj, A., Kaur, J., Wuest, M., & Wuest, F. (2017) · Nature Communications · doi:10.1038/s41467-016-0009-6 · Cited by 7,448
Cited by
2D Materials in Flexible Electronics: Recent Advances and Future Prospectives
Katiyar, A. K., Hoang, A. T., Xu, D., Hong, J., Kim, B. J., Ji, S., & Ahn, J.-H. (2024) · Chemical Reviews · doi:10.1021/acs.chemrev.3c00302 · Cited by 363
Two-dimensional devices and integration towards the silicon lines
Wang, S., Liu, X., Xu, M., Liu, L., Yang, D., & Zhou, P. (2022) · Nature Materials · doi:10.1038/s41563-022-01383-2 · Cited by 332
Two-Dimensional Field-Effect Transistor Sensors: The Road toward Commercialization
Dai, C., Liu, Y., & Wei, D. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00924 · Cited by 303
The Roadmap of 2D Materials and Devices Toward Chips
Liu, A., Zhang, X., Liu, Z., Li, Y., Peng, X., Li, X., Qin, Y., Hu, C., Qiu, Y., Jiang, H., et al. (2024) · Nano-Micro Letters · doi:10.1007/s40820-023-01273-5 · Cited by 255
Metadata
- Authors
- Hong, S., Zagni, N., Choo, S., Liu, N., Baek, S., Bala, A., Yoo, H., Kang, B. H., Kim, H. J., Yun, H. J., Alam, M. A., & Kim, S.
- Venue
- Nature Communications
- Published
- 2021-06-11
- Volume
- 12
- Issue
- 1
- Pages
- 3559-3559
- ISSN
- 2041-1723 (ISSN-L)
- OpenAlex
- W3170157348
- Cited by
- 169
- References
- 1
- FWCI
- 8.68
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Highly sensitive active pixel image sensor array driven by large-area bilayer MoS2 transistor circuitry. https://app.cochat.ai/papers/10.1038/s41467-021-23711-x
- The paper
- Hong, S., Zagni, N., Choo, S., Liu, N., Baek, S., Bala, A., Yoo, H., Kang, B. H., Kim, H. J., Yun, H. J., Alam, M. A., & Kim, S. (2021). Highly sensitive active pixel image sensor array driven by large-area bilayer MoS2 transistor circuitry. Nature Communications. https://doi.org/10.1038/s41467-021-23711-x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.