The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Self-healing polyurethane-elastomer with mechanical tunability for multiple biomedical applications in vivo
Open accessAbstract
The unique properties of self-healing materials hold great potential in the field of biomedical engineering. Although previous studies have focused on the design and synthesis of self-healing materials, their application in in vivo settings remains limited. Here, we design a series of biodegradable and biocompatible self-healing elastomers (SHEs) with tunable mechanical properties, and apply them to various disease models in vivo, in order to test their reparative potential in multiple tissues and at physiological conditions. We validate the effectiveness of SHEs as promising therapies for aortic aneurysm, nerve coaptation and bone immobilization in three animal models. The data presented here support the translation potential of SHEs in diverse settings, and pave the way for the development of self-healing materials in clinical contexts.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Silica-Like Malleable Materials from Permanent Organic Networks
Montarnal, D., Capelot, M., Tournilhac, F., & Leibler, L. (2011) · Science · doi:10.1126/science.1212648 · Cited by 3,625
Animal research: Reporting in vivo experiments: The ARRIVE guidelines
Kilkenny, C., Browne, W., Cuthill, I. C., Emerson, M., & Altman, D. G. (2010) · British Journal of Pharmacology · doi:10.1111/j.1476-5381.2010.00872.x · Cited by 3,625
Kang, J., Tok, J. B.-H., & Bao, Z. (2019) · Nature Electronics · doi:10.1038/s41928-019-0235-0 · Cited by 706
Failure mode analysis of silicon-based intracortical microelectrode arrays in non-human primates
Barrese, J. C., Rao, N., Paroo, K., Triebwasser, C., Vargas-Irwin, C., Franquemont, L., & Donoghue, J. P. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/6/066014 · Cited by 600
Oller, J., Méndez-Barbero, N., Ruiz, E. J., Villahoz, S., Renard, M., Canelas, L. I., Briones, A. M., Alberca, R., Lozano-Vidal, N., Hurlé, M. A., et al. (2017) · Nature Medicine · doi:10.1038/nm.4266 · Cited by 177
Cited by
Self-healing polyurethane with high strength and toughness based on a dynamic chemical strategy
Dong, F., Yang, X., Guo, L., Wang, Y., Shaghaleh, H., Huang, Z., Xu, X., Wang, S., & Liu, H. (2022) · Journal of Materials Chemistry A · doi:10.1039/d2ta00802e · Cited by 285
Metadata
- Authors
- Jiang, C., Zhang, L., Yang, Q., Huang, S., Shi, H., Long, Q., Qian, B., Liu, Z., Guan, Q., Liu, M., Yang, R., Zhao, Q., You, Z., & Ye, X.
- Venue
- Nature Communications
- Published
- 2021-07-20
- Volume
- 12
- Issue
- 1
- Pages
- 4395-4395
- ISSN
- 2041-1723 (ISSN-L)
- OpenAlex
- W3183407171
- Cited by
- 230
- References
- 6
- FWCI
- 11.52
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Self-healing polyurethane-elastomer with mechanical tunability for multiple biomedical applications in vivo. https://app.cochat.ai/papers/10.1038/s41467-021-24680-x
- The paper
- Jiang, C., Zhang, L., Yang, Q., Huang, S., Shi, H., Long, Q., Qian, B., Liu, Z., Guan, Q., Liu, M., Yang, R., Zhao, Q., You, Z., & Ye, X. (2021). Self-healing polyurethane-elastomer with mechanical tunability for multiple biomedical applications in vivo. Nature Communications. https://doi.org/10.1038/s41467-021-24680-x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.