The DOI matches its Crossref record.
A method for quantitatively separating the piezoelectric component from the as-received “Piezoelectric” signal
Open accessAbstract
Polymer-based piezoelectric devices are promising for developing future wearable force sensors, nanogenerators, and implantable electronics, etc. The electric signals generated by them are often assumed as solely coming from the piezoelectric effect. However, triboelectric signals originated from contact electrification between the piezoelectric devices and the contacted objects can produce non-negligible interfacial electron transfer, which is often combined with the piezoelectric signal to give a triboelectric-piezoelectric hybrid output, leading to an exaggerated measured “piezoelectric” signal. Herein, a simple and effective method is proposed for quantitatively identifying and extracting the piezoelectric charge from the hybrid signal. The triboelectric and piezoelectric parts in the hybrid signal generated by a poly(vinylidene fluoride)-based device are clearly differentiated, and their force and charge characteristics in the time domain are identified. This work presents an effective method to elucidate the true piezoelectric performance in practical measurement, which is crucial for evaluating piezoelectric materials fairly and correctly.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Choi, D., Lee, Y., Lin, Z.-H., Cho, S., Kim, M., Ao, C. K., Soh, S., Sohn, C., Jeong, C. K., Lee, J., et al. (2023) · ACS Nano · doi:10.1021/acsnano.2c12458 · Cited by 656
Self-citationChen, S., Zhu, P., Mao, L., Wu, W., Lin, H., Xu, D., Lu, X., & Shi, J. (2023) · Advanced Materials · doi:10.1002/adma.202208256 · Cited by 363
Porous Conductive Textiles for Wearable Electronics
Ding, Y., Jiang, J., Wu, Y., Zhang, Y., Zhou, J., Zhang, Y., Huang, Q., & Zheng, Z. (2024) · Chemical Reviews · doi:10.1021/acs.chemrev.3c00507 · Cited by 269
Wang, T., Ouyang, H., Luo, Y., Xue, J., Wang, E., Zhang, L., Zhou, Z., Liu, Z., Li, X., Tan, S., et al. (2024) · Science Advances · doi:10.1126/sciadv.adi6799 · Cited by 161
Metadata
- Authors
- Chen, C., Zhao, S., Pan, C., Zi, Y., Wang, F., Yang, C., & Wang, Z. L.
- Venue
- Nature Communications
- Published
- 2022-03-16
- Volume
- 13
- Issue
- 1
- Pages
- 1391-1391
- ISSN
- 2041-1723 (ISSN-L)
- OpenAlex
- W4220928338
- Cited by
- 213
- References
- 0
- FWCI
- 11.60
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A method for quantitatively separating the piezoelectric component from the as-received “Piezoelectric” signal. https://app.cochat.ai/papers/10.1038/s41467-022-29087-w
- The paper
- Chen, C., Zhao, S., Pan, C., Zi, Y., Wang, F., Yang, C., & Wang, Z. L. (2022). A method for quantitatively separating the piezoelectric component from the as-received “Piezoelectric” signal. Nature Communications. https://doi.org/10.1038/s41467-022-29087-w
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.