Cited by 141Spaceflight effects on biologySpace Exploration and TechnologyMuscle Physiology and Disorders

Towards human exploration of space: the THESEUS review series on muscle and bone research priorities

Open access
Lang, Thomas, Van Loon, Jack J.W.A., Bloomfield, Susan, Vico, Laurence, Chopard, Angele, Rittweger, Joern, Kyparos, Antonios, Blottner, Dieter +3 more·2017·npj Microgravity

Abstract

Without effective countermeasures, the musculoskeletal system is altered by the microgravity environment of long-duration spaceflight, resulting in atrophy of bone and muscle tissue, as well as in deficits in the function of cartilage, tendons, and vertebral disks. While inflight countermeasures implemented on the International Space Station have evidenced reduction of bone and muscle loss on low-Earth orbit missions of several months in length, important knowledge gaps must be addressed in order to develop effective strategies for managing human musculoskeletal health on exploration class missions well beyond Earth orbit. Analog environments, such as bed rest and/or isolation environments, may be employed in conjunction with large sample sizes to understand sex differences in countermeasure effectiveness, as well as interaction of exercise with pharmacologic, nutritional, immune system, sleep and psychological countermeasures. Studies of musculoskeletal biomechanics, involving both human subject and computer simulation studies, are essential to developing strategies to avoid bone fractures or other injuries to connective tissue during exercise and extravehicular activities. Animal models may be employed to understand effects of the space environment that cannot be modeled using human analog studies. These include studies of radiation effects on bone and muscle, unraveling the effects of genetics on bone and muscle loss, and characterizing the process of fracture healing in the mechanically unloaded and immuno-compromised spaceflight environment. In addition to setting the stage for evidence-based management of musculoskeletal health in long-duration space missions, the body of knowledge acquired in the process of addressing this array of scientific problems will lend insight into the understanding of terrestrial health conditions such as age-related osteoporosis and sarcopenia.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1038/s41526-017-0013-0

Cites

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Current standards to monitor and maintain bone health in NASA and ISS crewmembers are based on BMD measurements by dual-energy x-ray absorptiometry (DXA).

    “Current standards to monitor and maintain bone health in both NASA and ISS crewmembers are based in BMD measurements by dual-energy x-ray absorptiometry (DXA) [5].”

    From A human mission to Mars: Predicting the bone mineral density loss of astronauts (2020) · cites this paper as [5]

    The “Early findings of bone loss in long-duration missions” section describes pre- and post-flight DXA BMD measurements, and “Countermeasure studies” reports DXA measurements used to assess bone-loss interventions in ISS crews. These passages support the use of DXA BMD to monitor bone health, but they do not establish that current NASA and ISS standards for monitoring and maintaining bone health are based on it. No page numbers were provided in our copy. (LLM, conf=0.83)

    Experimental — accuracy not yet measured

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

The citation lists haven’t been fetched yet

References 119 · Cited by 141

Research works printed but not linked: 2

  1. [55]Hoff P Effects of 60-day bed rest with and without exercise on cellular and humoral immunological parameters Cell. Mol. Immunol. 2015 12 483 492 10.1038/cmi.2014.106 25382740 PMC4496533 · DOI
  2. [74]Schneider SM Treadmill exercise within lower body negative pressure protects leg lean tissue mass and extensor strength and endurance during bed rest Physiol Rep 2016 4 e12892 10.14814/phy2.12892 27495299 PMC4985554 · DOI

Authors
Lang, T., Van Loon, J. J. W. A., Bloomfield, S., Vico, L., Chopard, A., Rittweger, J., Kyparos, A., Blottner, D., Vuori, I., Gerzer, R., & Cavanagh, P. R.
Affiliations
  • University of California, San Francisco (US)
  • Texas A&M University (US)
  • Inserm (FR)
  • Aristotle University of Thessaloniki (GR)
  • Charité – Universitätsmedizin Berlin (DE)
  • Urho Kaleva Kekkonen Institute (FI)
  • Skolkovo Institute of Science and Technology (RU)
  • University of Washington Medical Center (US)
Corresponding author
Lang, Thomas
Venue
npj Microgravity
Published
2017-02-14
Volume
3
Issue
1
Pages
8-8
ISSN
2373-8065 (ISSN-L)
OpenAlex
W2588015198
Cited by
141
References
119
Citations by year
2026: 4 · 2025: 14 · 2024: 19 · 2023: 14 · 2022: 19 · 2021: 23 · 2020: 16 · 2019: 15 · 2018: 13 · 2017: 3
FWCI
9.51
Type
journal article
Language
en
Open access
Locations
  • npj Microgravity (publishedVersion, cc-by)
  • Europe PMC (PubMed Central) (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • Kölner Universitäts PublikationsServer (Universität zu Köln) (publishedVersion)
  • Pure Amsterdam UMC (publishedVersion, other-oa)
  • Amsterdam UMC (VU Amsterdam) - Institutional Repository (publishedVersion)
  • elib (German Aerospace Center) (submittedVersion, cc-by)
  • HAL (submittedVersion, cc-by)
  • UvA-DARE (University of Amsterdam) (submittedVersion, cc-by)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
  • eScholarship (California Digital Library) (submittedVersion)
  • eScholarship (California Digital Library) (submittedVersion, cc-by)
  • VU Research Portal (submittedVersion, cc-by)
  • Data Archiving and Networked Services (DANS) (submittedVersion, other-oa)
  • Data Archiving and Networked Services (DANS) (submittedVersion, cc-by)
  • Data Archiving and Networked Services (DANS) (submittedVersion)
Funders
  • European Commission (242482)
  • European Science Foundation
Topics
  • Health Sciences › Medicine › Physiology › Spaceflight effects on biology
  • Physical Sciences › Engineering › Aerospace Engineering › Space Exploration and Technology
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Muscle Physiology and Disorders
Keywords
microgravity, bone atrophy, muscle atrophy, countermeasures, long-duration spaceflight, sex differences, exercise countermeasures, musculoskeletal biomechanics, fracture risk, extravehicular activity, radiation effects on bone, fracture healing, immune compromise, osteoporosis, sarcopenia, human space exploration

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review