Cited by 231Retinal and Macular SurgeryIntraocular Surgery and LensesTeleoperation and Haptic Systems

First-in-human study of the safety and viability of intraocular robotic surgery

Open access
Edwards, T. L., Xue, K., Meenink, H. C. M., Beelen, M. J., Naus, G. J. L., Simunovic, M. P., Latasiewicz, M., Farmery, A. D. +2 more·2018·Nature Biomedical Engineering

Abstract

Microsurgery of the retina would be dramatically improved by instruments that offer supra-human precision. Here, we report the results of a first-in-human study of remotely controlled robot-assisted retinal surgery performed through a telemanipulation device. Specifically, 12 patients requiring dissection of the epiretinal or inner limiting membrane over the macula were randomly assigned to either undergo robot-assisted-surgery or manual surgery, under general anaesthesia. We evaluated surgical success, duration of surgery and amount of retinal microtrauma as a proxy for safety. Surgical outcomes were equally successful in the robotic-surgery and manual-surgery groups. Differences in the amount of retinal microtrauma between the two groups were statistically insignificant, yet dissection took longer with robotic surgery (median time, 4 min 5 s) than with manual surgery (1 min 20 s). We also show the feasibility of using the robot to inject recombinant tissue plasminogen activator under the retina to displace sight-threatening haemorrhage in three patients under local anaesthesia. A safe and viable robotic system for intraocular surgery would enable precise and minimally traumatic delivery of gene therapy or cell therapy to the retina.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1038/s41551-018-0248-4

Cites

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • One avenue to further improve surgical precision and to reduce reflux during direct subretinal injection is to use robotic assistance.

    “One avenue to further improve surgical precision and to reduce reflux during direct subretinal injection is to use robotic assistance (Edwards et al., 2018; Cehajic-Kapetanovic et al., 2022).”

    From Gene Therapy-Associated Uveitis (GTAU): Understanding and mitigating the adverse immune response in retinal gene therapy (2025) · cites this paper as Edwards et al., 2018

    The Introduction describes robotic assistance as a way to overcome tremor and improve precision, and the Results describe controlled robot-assisted subretinal injection. Neither those passages nor the Discussion reports that robotic assistance reduces reflux during injection. (LLM, conf=0.88)

    Experimental — accuracy not yet measured

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

The citation lists haven’t been fetched yet

References 34 · Cited by 231

Authors
Edwards, T. L., Xue, K., Meenink, H. C. M., Beelen, M. J., Naus, G. J. L., Simunovic, M. P., Latasiewicz, M., Farmery, A. D., de Smet, M. D., & MacLaren, R. E.
Affiliations
  • University of Oxford (GB)
  • Oxford University Hospitals NHS Trust (GB)
Corresponding author
MacLaren, R. E.
Venue
Nature Biomedical Engineering
Published
2018-06-18
Volume
2
Issue
9
Pages
649-656
ISSN
2157-846X (ISSN-L)
OpenAlex
W2808253872
Cited by
231
References
34
Citations by year
2026: 32 · 2025: 37 · 2024: 23 · 2023: 30 · 2022: 29 · 2021: 24 · 2020: 22 · 2019: 28 · 2018: 6
FWCI
13.82
Type
journal article
Language
en
Open access
Locations
  • Nature Biomedical Engineering (publishedVersion)
  • PubMed (publishedVersion)
  • Europe PMC (PubMed Central) (acceptedVersion)
  • PubMed Central (acceptedVersion)
  • Leiden Repository (Leiden University) (submittedVersion)
  • Data Archiving and Networked Services (DANS) (submittedVersion, other-oa)
  • TU/e Research Portal (submittedVersion)
Funders
  • National Institute for Health and Care Research (NF-SI-0515-10047, II-C2-0713-20005)
  • University of Oxford
Topics
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Retinal and Macular Surgery
  • Health Sciences › Medicine › Ophthalmology › Intraocular Surgery and Lenses
  • Physical Sciences › Engineering › Mechanical Engineering › Teleoperation and Haptic Systems
Keywords
teleoperation, epiretinal membrane, internal limiting membrane, macula, operative time, subretinal hemorrhage, gene therapy delivery, cell therapy delivery, first-in-human safety

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review