The DOI matches its Crossref record; 38 of the 38 references it cites were found in a registry or an index.
High-coherence mid-infrared dual-comb spectroscopy spanning 2.6 to 5.2 μm
Open accessAbstract
Mid-infrared dual-comb spectroscopy has the potential to supplant conventional Fourier-transform spectroscopy in applications requiring high resolution, accuracy, signal-to-noise ratio and speed. Until now, mid-infrared dual-comb spectroscopy has been limited to narrow optical bandwidths or low signal-to-noise ratios. Using digital signal processing and broadband frequency conversion in waveguides, we demonstrate a mid-infrared dual-comb spectrometer covering 2.6 to 5.2 µm with comb-tooth resolution, sub-MHz frequency precision and accuracy, and a spectral signal-to-noise ratio as high as 6,500. As a demonstration, we measure the highly structured, broadband cross-section of propane from 2,840 to 3,040 cm−1, the complex phase/amplitude spectra of carbonyl sulfide from 2,000 to 2,100 cm−1, and of a methane, acetylene and ethane mixture from 2,860 to 3,400 cm−1. The combination of broad bandwidth, comb-mode resolution and high brightness will enable accurate mid-infrared spectroscopy in precision laboratory experiments and non-laboratory applications including open-path atmospheric gas sensing, process monitoring and combustion.By employing difference-frequency generation, a mid-infrared dual-comb spectrometer covering the 2.6 to 5.2 µm range is demonstrated with comb-tooth resolution, sub-MHz frequency precision and accuracy, and a spectral signal-to-noise ratio as high as 6,500.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The HITRAN 2008 molecular spectroscopic database
Rothman, L. S., Gordon, I. E., Barbe, A., Benner, D. C., Bernath, P. F., Birk, M., Boudon, V., Brown, L. R., Campargue, A., Champion, J.-P., et al. (2009) · Journal of Quantitative Spectroscopy and Radiative Transfer · doi:10.1016/j.jqsrt.2009.02.013 · Cited by 3,335
Coddington, I., Newbury, N., & Swann, W. (2016) · Optica · doi:10.1364/optica.3.000414 · Cited by 1,754
Self-citationSchliesser, A., Picqué, N., & Hänsch, T. W. (2012) · Nature Photonics · doi:10.1038/nphoton.2012.142 · Cited by 1,436
Dual-comb spectroscopy based on quantum-cascade-laser frequency combs
Villares, G., Hugi, A., Blaser, S., & Faist, J. (2014) · Nature Communications · doi:10.1038/ncomms6192 · Cited by 529
Adaptive real-time dual-comb spectroscopy
Ideguchi, T., Poisson, A., Guelachvili, G., Picqué, N., & Hänsch, T. W. (2014) · Nature Communications · doi:10.1038/ncomms4375 · Cited by 434
Frequency-comb infrared spectrometer for rapid, remote chemical sensing
Schliesser, A., Brehm, M., Keilmann, F., & van der Weide, D. W. (2005) · Optics Express · doi:10.1364/opex.13.009029 · Cited by 384
Coherent dual-comb spectroscopy at high signal-to-noise ratio
Coddington, I., Swann, W., & Newbury, N. (2010) · Physical Review A · doi:10.1103/physreva.82.043817 · Cited by 322
Self-citationSensitivity of coherent dual-comb spectroscopy
Newbury, N. R., Coddington, I., & Swann, W. (2010) · Optics Express · doi:10.1364/oe.18.007929 · Cited by 283
Self-citationSpectroscopy of the methaneν3band with an accurate midinfrared coherent dual-comb spectrometer
Baumann, E., Giorgetta, F. R., Swann, W. C., Zolot, A. M., Coddington, I., & Newbury, N. R. (2011) · Physical Review A · doi:10.1103/physreva.84.062513 · Cited by 252
Self-citationContinuous real-time correction and averaging for frequency comb interferometry
Roy, J., Deschênes, J.-D., Potvin, S., & Genest, J. (2012) · Optics Express · doi:10.1364/oe.20.021932 · Cited by 245
Cited by
Picqué, N., & Hänsch, T. W. (2019) · Nature Photonics · doi:10.1038/s41566-018-0347-5 · Cited by 1,255
20 years of developments in optical frequency comb technology and applications
Fortier, T., & Baumann, E. (2019) · Communications Physics · doi:10.1038/s42005-019-0249-y · Cited by 963
Self-citationOptical frequency combs: Coherently uniting the electromagnetic spectrum
Diddams, S. A., Vahala, K., & Udem, T. (2020) · Science · doi:10.1126/science.aay3676 · Cited by 714
Self-citationHigh-speed long-wave infrared ultra-thin photodetectors
Wang, Y., Muhowski, A. J., Nordin, L., Dev, S., Allen, M., Allen, J., & Wasserman, D. (2024) · APL Photonics · doi:10.1063/5.0181052 · Cited by 13
Okano, M., Suyama, K., Wada, A., & Tanaka, S. (2025) · Journal of the Optical Society of America B · doi:10.1364/josab.560569
Metadata
- Authors
- Ycas, G., Giorgetta, F. R., Baumann, E., Coddington, I., Herman, D., Diddams, S. A., & Newbury, N. R.
- Venue
- Nature Photonics
- Published
- 2018-03-19
- Volume
- 12
- Issue
- 4
- Pages
- 202-208
- ISSN
- 1749-4885 (ISSN-L)
- 1749-4893
- OpenAlex
- W2760212797
- Cited by
- 349
- References
- 38
- FWCI
- 17.37
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: High-coherence mid-infrared dual-comb spectroscopy spanning 2.6 to 5.2 μm. https://app.cochat.ai/papers/10.1038/s41566-018-0114-7
- The paper
- Ycas, G., Giorgetta, F. R., Baumann, E., Coddington, I., Herman, D., Diddams, S. A., & Newbury, N. R. (2018). High-coherence mid-infrared dual-comb spectroscopy spanning 2.6 to 5.2 μm. Nature Photonics. https://doi.org/10.1038/s41566-018-0114-7
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.