Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 336

The DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.

Thermophotovoltaic efficiency of 40%

Open access
LaPotin, Alina, Schulte, Kevin L., Steiner, Myles A., Buznitsky, Kyle, Kelsall, Colin C., Friedman, Daniel J., Tervo, Eric J., France, Ryan M., Young, Michelle R., Rohskopf, Andrew, Verma, Shomik, Wang, Evelyn N., Henry, Asegun·2022·Nature

Abstract

Thermophotovoltaics (TPVs) convert predominantly infrared wavelength light to electricity via the photovoltaic effect, and can enable approaches to energy storage 1,2 and conversion 3–9 that use higher temperature heat sources than the turbines that are ubiquitous in electricity production today. Since the first demonstration of 29% efficient TPVs (Fig. 1a) using an integrated back surface reflector and a tungsten emitter at 2,000 °C (ref.10), TPV fabrication and performance have improved 11,12. However, despite predictions that TPV efficiencies can exceed 50% (refs.11,13,14), the demonstrated efficiencies are still only as high as 32%, albeit at much lower temperatures below 1,300 °C (refs.13–15). Here we report the fabrication and measurement of TPV cells with efficiencies of more than 40% and experimentally demonstrate the efficiency of high-bandgap tandem TPV cells. The TPV cells are two-junction devices comprising III–V materials with bandgaps between 1.0 and 1.4 eV that are optimized for emitter temperatures of 1,900–2,400 °C. The cells exploit the concept of band-edge spectral filtering to obtain high efficiency, using highly reflective back surface reflectors to reject unusable sub-bandgap radiation back to the emitter. A 1.4/1.2 eV device reached a maximum efficiency of (41.1 ± 1)% operating at a power density of 2.39 W cm–2 and an emitter temperature of 2,400 °C. A 1.2/1.0 eV device reached a maximum efficiency of (39.3 ± 1)% operating at a power density of 1.8 W cm–2 and an emitter temperature of 2,127 °C. These cells can be integrated into a TPV system for thermal energy grid storage to enable dispatchable renewable energy. This creates a pathway for thermal energy grid storage to reach sufficiently high efficiency and sufficiently low cost to enable decarbonization of the electricity grid.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1038/s41586-022-04473-y

Cites

28 of 28 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 28 references

Cited by

Metadata

Authors
LaPotin, A., Schulte, K. L., Steiner, M. A., Buznitsky, K., Kelsall, C. C., Friedman, D. J., Tervo, E. J., France, R. M., Young, M. R., Rohskopf, A., Verma, S., Wang, E. N., & Henry, A.
Venue
Nature
Published
2022-04-13
Volume
604
Issue
7905
Pages
287-291
ISSN
  • 0028-0836 (ISSN-L)
  • 1476-4687
OpenAlex
W3195805204
Cited by
336
References
28
FWCI
30.46
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Thermophotovoltaic efficiency of 40%. https://app.cochat.ai/papers/10.1038/s41586-022-04473-y
The paper
LaPotin, A., Schulte, K. L., Steiner, M. A., Buznitsky, K., Kelsall, C. C., Friedman, D. J., Tervo, E. J., France, R. M., Young, M. R., Rohskopf, A., Verma, S., Wang, E. N., & Henry, A. (2022). Thermophotovoltaic efficiency of 40%. Nature. https://doi.org/10.1038/s41586-022-04473-y

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.