Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 166

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Self-powered perovskite photon-counting detectors

Open access
Zhou, Ying, Fei, Chengbin, Uddin, Md Aslam, Zhao, Liang, Ni, Zhenyi, Huang, Jinsong · 2023 · Nature

Abstract

Metal-halide perovskites (MHPs) have been successfully exploited for converting photons to charges or vice versa in applications of solar cells, light-emitting diodes and solar fuels^ 1 – 3 , for which all these applications involve strong light. Here we show that self-powered polycrystalline perovskite photodetectors can rival the commercial silicon photomultipliers (SiPMs) for photon counting. The photon-counting capability of perovskite photon-counting detectors (PCDs) is mainly determined by shallow traps, despite that deep traps also limit charge-collection efficiency. Two shallow traps with energy depth of 5.8 ± 0.8 millielectronvolts (meV) and 57.2 ± 0.1 meV are identified in polycrystalline methylammonium lead triiodide, which mainly stay at grain boundaries and the surface, respectively. We show that these shallow traps can be reduced by grain-size enhancement and surface passivation using diphenyl sulfide, respectively. It greatly suppresses dark count rate (DCR) from >20,000 counts per second per square millimetre (cps mm^−2) to 2 cps mm^−2 at room temperature, enabling much better response to weak light than SiPMs. The perovskite PCDs can collect γ-ray spectra with better energy resolution than SiPMs and maintain performance at high temperatures up to 85 °C. The zero-bias operation of perovskite detectors enables no drift of noise and detection property. This study opens a new application of photon counting for perovskites that uses their unique defect properties. Suppression of shallow traps responsible for dark count rates in polycrystalline methylammonium lead triiodide using diphenyl sulfide enables the production of metal-halide perovskite photon-counting detectors that allow sensitive detection of γ-ray spectra.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1038/s41586-023-05847-6

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 166

Metadata

Authors
Zhou, Y., Fei, C., Uddin, M. A., Zhao, L., Ni, Z., & Huang, J.
Venue
Nature
Published
2023-04-05
Volume
616
Issue
7958
Pages
712-718
ISSN
  • 0028-0836 (ISSN-L)
  • 1476-4687
OpenAlex
W4362607989
Cited by
166
References
1
FWCI
30.71
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Self-powered perovskite photon-counting detectors. https://app.cochat.ai/papers/10.1038/s41586-023-05847-6
The paper
Zhou, Y., Fei, C., Uddin, M. A., Zhao, L., Ni, Z., & Huang, J. (2023). Self-powered perovskite photon-counting detectors. Nature. https://doi.org/10.1038/s41586-023-05847-6

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.