Increasing the accuracy of nanopore DNA sequencing using a time-varying cross membrane voltage
Open accessThe DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
Nanopore DNA sequencing is limited by low base-calling accuracy. Improved base-calling accuracy has so far relied on specialized base-calling algorithms, different nanopores and motor enzymes, or biochemical methods to re-read DNA molecules. Two primary error modes hamper sequencing accuracy: enzyme mis-steps and sequences with indistinguishable signals. We vary the driving voltage from 100 to 200 mV, with a frequency of 200 Hz, across a Mycobacterium smegmatis porin A (MspA) nanopore, thus changing how the DNA strand moves through the nanopore. A DNA helicase moves the DNA through the nanopore in discrete steps, and the variable voltage moves the DNA continuously between these steps. The electronic signal produced with variable voltage is used to overcome the primary error modes in base calling. We found that single-passage de novo base-calling accuracy of 62.7 ± 0.5% with a constant driving voltage improves to 79.3 ± 0.3% with a variable driving voltage. The variable-voltage sequencing mode is complementary to other methods to boost the accuracy of nanopore sequencing and could be incorporated into any enzyme-actuated nanopore sequencing device. The accuracy of nanopore DNA sequencing is substantially improved by application of a variable-voltage sequencing mode.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Nanopore sequencing and assembly of a human genome with ultra-long reads
Jain, M., Koren, S., Miga, K. H., Quick, J., Rand, A. C., Sasani, T. A., Tyson, J. R., Beggs, A. D., Dilthey, A. T., Fiddes, I. T., et al. (2018) · Nature Biotechnology · doi:10.1038/nbt.4060 · Cited by 1,892
Establishment and cryptic transmission of Zika virus in Brazil and the Americas
Faria, N. R., Quick, J., Claro, I. M., Thézé, J., de Jesus, J. G., Giovanetti, M., Kraemer, M. U. G., Hill, S. C., Black, A., da Costa, A. C., et al. (2017) · Nature · doi:10.1038/nature22401 · Cited by 616
Mapping DNA methylation with high-throughput nanopore sequencing
Rand, A. C., Jain, M., Eizenga, J. M., Musselman-Brown, A., Olsen, H. E., Akeson, M., & Paten, B. (2017) · Nature Methods · doi:10.1038/nmeth.4189 · Cited by 507
Detection and mapping of 5-methylcytosine and 5-hydroxymethylcytosine with nanopore MspA
Laszlo, A. H., Derrington, I. M., Brinkerhoff, H., Langford, K. W., Nova, I. C., Samson, J. M., Bartlett, J. J., Pavlenok, M., & Gundlach, J. H. (2013) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1310240110 · Cited by 321 · cited 1×
“In both cases, we used a hidden Markov model (HMM) (Supplementary Note 6) to decode the generating DNA sequence for the observed signal.”
Self-citationMinION Analysis and Reference Consortium: Phase 2 data release and analysis of R9.0 chemistry
Jain, M., Tyson, J. R., Loose, M., Ip, C. L. C., Eccles, D. A., O'Grady, J., Malla, S., Leggett, R. M., Wallerman, O., Jansen, H. J., et al. (2017) · F1000Research · doi:10.12688/f1000research.11354.1 · Cited by 140
Cited by
Opportunities and challenges in long-read sequencing data analysis
Amarasinghe, S. L., Su, S., Dong, X., Zappia, L., Ritchie, M. E., & Gouil, Q. (2020) · Genome Biology · doi:10.1186/s13059-020-1935-5 · Cited by 2,530
Nanopore sequencing technology, bioinformatics and applications
Wang, Y., Zhao, Y., Bollas, A., Wang, Y., & Au, K. F. (2021) · Nature Biotechnology · doi:10.1038/s41587-021-01108-x · Cited by 1,753
Multiple rereads of single proteins at single–amino acid resolution using nanopores
Brinkerhoff, H., Kang, A. S. W., Liu, J., Aksimentiev, A., & Dekker, C. (2021) · Science · doi:10.1126/science.abl4381 · Cited by 461
Self-citationFluids and Electrolytes under Confinement in Single-Digit Nanopores
Aluru, N. R., Aydin, F., Bazant, M. Z., Blankschtein, D., Brozena, A. H., de Souza, J. P., Elimelech, M., Faucher, S., Fourkas, J. T., Koman, V. B., et al. (2023) · Chemical Reviews · doi:10.1021/acs.chemrev.2c00155 · Cited by 224
Tabatabaei, S. K., Pham, B., Pan, C., Liu, J., Chandak, S., Shorkey, S. A., Hernandez, A. G., Aksimentiev, A., Chen, M., Schroeder, C. M., et al. (2022) · Nano Letters · doi:10.1021/acs.nanolett.1c04203 · Cited by 63
“These results are consistent with prior work reporting that tuning the applied bias is a useful approach to enhance the accuracy of nanopore-based sequencing methods (21).”
Result
Metadata
- Authors
- Noakes, M. T., Brinkerhoff, H., Laszlo, A. H., Derrington, I. M., Langford, K. W., Mount, J. W., Bowman, J. L., Baker, K. S., Doering, K. M., Tickman, B. I., & Gundlach, J. H.
- Venue
- Nature Biotechnology
- Published
- 2019-04-22
- Volume
- 37
- Issue
- 6
- Pages
- 651-656
- ISSN
- 0733-222X (ISSN-L)
- 1087-0156
- 1546-1696
- OpenAlex
- W2938720998
- Cited by
- 122
- References
- 5
- FWCI
- 4.98
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.