The cryo-EM method microcrystal electron diffraction (MicroED)
Open accessAbstract
In 2013 we established a cryo-electron microscopy (cryo-EM) technique called microcrystal electron diffraction (MicroED). Since that time, data collection and analysis schemes have been fine-tuned, and structures for more than 40 different proteins, oligopeptides and organic molecules have been determined. Here we review the MicroED technique and place it in context with other structure-determination methods. We showcase example structures solved by MicroED and provide practical advice to prospective users. This paper reviews the cryo-EM technique of microcrystal electron diffraction (MicroED), providing a broad overview of the technique, the unique structures determined, and the opportunities for future development.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
PHENIX : a comprehensive Python-based system for macromolecular structure solution
Adams, P. D., Afonine, P. V., Bunkóczi, G., Chen, V. B., Davis, I. W., Echols, N., Headd, J. J., Hung, L.-W., Kapral, G. J., Grosse-Kunstleve, R. W., et al. (2010) · Acta Crystallographica Section D Biological Crystallography · doi:10.1107/s0907444909052925 · Cited by 23,716
Kabsch, W. (2010) · Acta Crystallographica Section D Biological Crystallography · doi:10.1107/s0907444909047337 · Cited by 16,463
Overview of the CCP 4 suite and current developments
Winn, M. D., Ballard, C. C., Cowtan, K. D., Dodson, E. J., Emsley, P., Evans, P. R., Keegan, R. M., Krissinel, E. B., Leslie, A. G. W., McCoy, A., et al. (2011) · Acta Crystallographica Section D Biological Crystallography · doi:10.1107/s0907444910045749 · Cited by 12,353
Cited by
Computational approaches streamlining drug discovery
Sadybekov, A. V., & Katritch, V. (2023) · Nature · doi:10.1038/s41586-023-05905-z · Cited by 1,279
Two-Dimensional Polymers and Polymerizations
Evans, A. M., Strauss, M. J., Corcos, A. R., Hirani, Z., Ji, W., Hamachi, L. S., Aguilar-Enriquez, X., Chavez, A. D., Smith, B. J., & Dichtel, W. R. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.0c01184 · Cited by 324
Protein X-ray Crystallography and Drug Discovery
Maveyraud, L., & Mourey, L. (2020) · Molecules · doi:10.3390/molecules25051030 · Cited by 269
AlphaFold 2 and NMR Spectroscopy: Partners to Understand Protein Structure, Dynamics and Function
Laurents, D. V. (2022) · Frontiers in Molecular Biosciences · doi:10.3389/fmolb.2022.906437 · Cited by 95
Metadata
- Authors
- Nannenga, B. L., & Gonen, T.
- Venue
- Nature Methods
- Published
- 2019-04-29
- Volume
- 16
- Issue
- 5
- Pages
- 369-379
- ISSN
- 1548-7091 (ISSN-L)
- 1548-7105
- OpenAlex
- W2942522093
- Cited by
- 229
- References
- 3
- FWCI
- 14.85
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The cryo-EM method microcrystal electron diffraction (MicroED). https://app.cochat.ai/papers/10.1038/s41592-019-0395-x
- The paper
- Nannenga, B. L., & Gonen, T. (2019). The cryo-EM method microcrystal electron diffraction (MicroED). Nature Methods. https://doi.org/10.1038/s41592-019-0395-x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.