Cited by 237Advanced Fluorescence Microscopy TechniquesOptical Imaging and Spectroscopy TechniquesSpectroscopy Techniques in Biomedical and Chemical Research

Light-sheet microscopy in the near-infrared II window

Open access
Wang, Feifei, Wan, Hao, Ma, Zhuoran, Zhong, Yeteng, Sun, Qinchao, Tian, Ye, Qu, Liangqiong, Du, Haotian +9 more·2019·Nature Methods

Abstract

Non-invasive deep-tissue three-dimensional optical imaging of live mammals with high spatiotemporal resolution is challenging owing to light scattering. We developed near-infrared II (1,000-1,700 nm) light-sheet microscopy with excitation and emission of up to approximately 1,320 nm and 1,700 nm, respectively, for optical sectioning at a penetration depth of approximately 750 μm through live tissues without invasive surgery and at a depth of approximately 2 mm in glycerol-cleared brain tissues. Near-infrared II light-sheet microscopy in normal and oblique configurations enabled in vivo imaging of live mice through intact tissue, revealing abnormal blood flow and T-cell motion in tumor microcirculation and mapping out programmed-death ligand 1 and programmed cell death protein 1 in tumors with cellular resolution. Three-dimensional imaging through the intact mouse head resolved vascular channels between the skull and brain cortex, and allowed monitoring of recruitment of macrophages and microglia to the traumatic brain injury site.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1038/s41592-019-0398-7

Cites

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

The citation lists haven’t been fetched yet

References 61 · Cited by 237

Authors
Wang, F., Wan, H., Ma, Z., Zhong, Y., Sun, Q., Tian, Y., Qu, L., Du, H., Zhang, M., Li, L., Ma, H., Luo, J., Liang, Y., Li, W. J., Hong, G., Liu, L., & Dai, H.
Affiliations
  • Stanford University (US)
  • University of North Carolina at Chapel Hill (US)
  • Wuhan University of Technology (CN)
  • VA Palo Alto Health Care System (US)
  • Southern University of Science and Technology (CN)
  • Shenyang Institute of Automation (CN)
Corresponding author
Dai, Hongjie
Venue
Nature Methods
Published
2019-05-13
Volume
16
Issue
6
Pages
545-552
ISSN
  • 1548-7091 (ISSN-L)
  • 1548-7105
OpenAlex
W2945756399
Cited by
237
References
61
Citations by year
2026: 25 · 2025: 33 · 2024: 32 · 2023: 29 · 2022: 36 · 2021: 37 · 2020: 36 · 2019: 8 · 2018: 1
FWCI
14.14
Type
journal article
Language
en
Open access
Locations
  • Nature Methods (publishedVersion)
  • PubMed (publishedVersion)
  • Europe PMC (PubMed Central) (acceptedVersion)
  • PubMed Central (acceptedVersion)
Funders
National Institute of Neurological Disorders and Stroke (DP1NS105737)
Topics
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Biophysics › Advanced Fluorescence Microscopy Techniques
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Optical Imaging and Spectroscopy Techniques
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Biophysics › Spectroscopy Techniques in Biomedical and Chemical Research
Keywords
light-sheet microscopy, deep tissue imaging, light scattering, in vivo imaging, mouse brain, tumor microcirculation, T cell motility, PD-L1, PD-1, traumatic brain injury, macrophage recruitment, skull imaging, vascular imaging
MeSH terms
Brain Injuries, Traumatic, Animals, Brain, Female, Fluorescent Dyes, Humans, Infrared Rays, Mice, Inbred BALB C, Mice, Inbred C57BL, Microscopy, Fluorescence, Tumor Cells, Cultured, Colorectal Neoplasms, Spectroscopy, Near-Infrared, Imaging, Three-Dimensional, Xenograft Model Antitumor Assays, Mice, Optical Imaging

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review